SiplaceX4_en - 第517页

1 - 1 1 S tudent Guide SIPLACE X Edition 09/2005 1 1 Sitest 11 1 1.2 Calibration WA R N I N G During some of the procedu res the gantri es will move. Therefore, before you beg in with any of these pr ocedure s make sure …

100%1 / 670
1 - 10
Student Guide SIPLACE X
11 Sitest Edition 09/2005
10
7.
8.
MTC
Calls the view for the functions
of the MTC.
Calls the view for the tower
functions of the MTC.
Calls the view for the axis
functions of the MTC.
Calls the view for the settings of
the MTC.
Calls the view for the machine
data functions of the MTC.
Calls the view for the inputs/
outputs of the MTC.
Calls the view for the inputs/
outputs of the MTC.
Inputs/Outputs
I/O module 1
I/O module 2
I/O module 3
I/O module 4
I/O module 5
I/O module 6
Lifting table and stopper, conveyor 1
Lifting table and stopper, conveyor 2
Belt motor, sonar Bero and width
adjustment, conveyor 1
Belt motor, sonar Bero and width
adjustment, conveyor 2
Interface, conveyor 1
Interface, conveyor 2
Options, conveyor 1
Options, conveyor 2
Conveyor width adjustment
1 - 11
Student Guide SIPLACE X
Edition 09/2005 11 Sitest
11
11.2 Calibration
WARNING
During some of the procedures the gantries will move.
Therefore, before you begin with any of these procedures make sure that you and everyone else
stay physically clear of the travel range of the gantries.
RISK OF INJURY!
Also, sure, that no objects are in the way. 11
11
Note:
Before you begin with the calibration, you must reference the heads and the gantries.
During calibration, unused gantries will automatically be moved to their parking position.
For a complete calibration of the placement system, the SITEST test program provides the func-
tion
"Calibrate machine..." which allows you to start all calibration functions from the menu "Calibrate
entire machine". 11
Equipment and Testing Tools
Test program SITEST, version 601.xx
Calibration tools
Version II transparent S/F/HS --> 00316308-03
Version III nontransparent HF/X with C&P6/12 and Twin head --> 03010565-01
Version SST 23 C&P 20 head --> 03034148-01
Nozzles, type 1235, 956, 517,518, Nozzle for Zero point correction Twin Head D-Axis
03008862-03)
Gauge
PCB with a width 100 mm
1 - 12
Student Guide SIPLACE X
11 Sitest Edition 09/2005
12
11.2.1 Calibration in general
Fig. 11.2 - 1 General sequence to calibrate the machine
Note:
Since the head modularity concept means that either a Twin Head or a C&P head can be fitted to
each gantry, the functions displayed for processing area 1(PA1) and processing area 2 (PA2) re-
spectively may vary. The functions described for PA1 and PA2 below apply for a Twin Head con-
figured on gantry 3 and a C&P head configured on gantry 1 on a X2 machine.
Sequence of calibrate the Siplace X machine with SW 601
Preperation the machine
All heads and cameras..
Sitest: Button "Calibrate machine...."
Calibrate and
teach of positions
(conveyor edges,
conveyor width,
PCB reference
corner, pick-up
positions)
PCB Mapping
Head Mapping
Gantry 1
(X2/X3/X4)