1 - 15
Student Guide SIPLACE X
Edition 09/2005 11 Sitest
15
Follow the Information and press the Start button on the maschine.
–Press OK
Now the head is calibration the Z- and Star zero point correction and save the new values in the
Achs_ver.ma and on the EEprom.
NOTE :Is this function not successful, please check the Travel range of the Z-axis.
The max. and min. travel range of the Z-axis(C&P20) are 34000 digits and -200 digits.
Function description: 11
The Z-Axis move up with the current sensor mode and set the counter to 0.
Then the Z- axis moves down to 18000 digits until the ball bearing of the Z- axis is between the
raceway of the star axis.
The star turns left and right and calculated the average value. This is the new zero point cor-
rection (
zpc) value of the star axis.
The Z- axis moves further down until the ball bearing (Segment) is in the center of the raceway
gap.
The star turns right into the gap of the raceway and the Z- axis push up the ball bearing against
the raceway. The Z-axis position is read.
Now the Z- axis position is read on the left side from the raceway gap with the same procedure,
like the right side.
Afterwards the new zero point correction of the Z- axis is calculated in the following way :
Z- position - diameter ball bearing - thickness of the raceway = new zpc Z- axis
NOTE : The data is directly stored in the Achse_ver.ma and in the EEPROM of the head.
1 - 16
Student Guide SIPLACE X
11 Sitest Edition 09/2005
16
11.2.4 Calibration positions in the machine
Fig. 11.2 - 2 Top view of machine
Key:
(1) Transport direction
(2) Fixed PCB corner BB 1/ 2 Track 1 and 2
(3) Machine zero point BB 1
(4) Calibration position BB 1 (depend on the head type)
(5) Machine zero point BB 2
(6) Calibration position BB 2 (depend on the head type)
Note:
Some calibrations require that you attach nozzles on the placement heads.
Use nozzles of type
956 for C&P6/12, 1235 for C&P20 and for the Twin head 517. Make sure that
all nozzles have been attached correctly, otherwise measuring will lead to incorrect results.
If you need to, place the calibration tool into the "calibration pocket". (Fig. 11.2 - 2).
Before you place the calibration tool, make sure that it is clean. Also, be sure that you insert it into
the "calibration pocket" with its print of the fiducial structure on the bottom. 11