SiplaceX4_en - 第58页
1 - 34 S tudent Guide SIPLACE X 2 Overview Edition 09/2005 34 2.2.10.1 Step s When Picking Up and Placing Component s – A PCB moves into the placement area of the PCB co nveyor and will be clamped. – After the fiducial m…

1 - 33
Student Guide SIPLACE X
Edition 09/2005 2 Overview
33
2.2.10 C&P Head Type DLM2 with 12/6 Segments
Depending on the configuration, the Siplace X machines can be equipped with C&P 12 or 6-seg-
ment heads of type DLM2.
Fig. 2.2 - 20 12-segment DLM 2 C&P head
(1) SP6_12 intermediate distribution board, digital
(2) Star motor
(3) Z-axis motor
(4) Stepping motor
(5) 24.5 x 24.5 component camera (SST.28)
(6) Vacuum system
Option: Digital camera SST.29 for the 12-segment C&P head and Component - sensor
(item no. 00118021-xx) for 0201 placement

1 - 34
Student Guide SIPLACE X
2 Overview Edition 09/2005
34
2.2.10.1 Steps When Picking Up and Placing Components
– A PCB moves into the placement area of the PCB conveyor and will be clamped.
– After the fiducial measurement, the C&P head picks up components from the feeder modules.
– The components are measured below the component camera and rotated into the correct
placement position (angle) in the DP station.
– The component is placed in star station 1.
2.2.10.2 Position and Function of the Individual Star Stations (see Fig. 2.2 - 21)
Star station 1 2
Pick-up cycle
The nozzle is lowered onto the component. The valve positioning unit opens the vacuum circuit to
the nozzle, the nozzle picks up the component and removes it from the feeder module.
Placement cycle
The nozzle, together with the component, is lowered onto the PCB that has been moved into
place. The valve positioning unit closes the vacuum channel to the nozzle. A short burst of com-
pressed air (air kiss) detaches the component from the nozzle and places it on the PCB.
Reject cycle
The valve positioning unit closes the vacuum channel to the nozzle. Defective components are
detached and discarded from the nozzle with a short burst of compressed air (air kiss).
Star station 3 (only used for the HS60 and S27 HM machines) 2
Note:
The HF- and Siplace X machines do not use star station 3 " reject component", as this function is
performed in star station 1.
Star station 7 2
The component is optically centered.
Star station 9 2
Pick-up cycle
The nozzle is rotated to the pick-up position.
Placement cycle
The component is rotated into the correct placement angle.

1 - 35
Student Guide SIPLACE X
Edition 09/2005 2 Overview
35
Between star stations 11 and 12 2
The optional "presence" and "height" of the component at the nozzle is checked by the compo-
nent sensor.
2.2.10.3 Function Overview for Star Stations 1 - 12
Fig. 2.2 - 21 Function overview of star stations 1 - 12
Star station 1:pick up, place or reject component
Star station 2:no function
Star station 3:no function
Star station 4, 5 and 6:no function
Star station 7:optically center component
Star station 8:no function
Star station 9:rotate the components
Star station 10:service position for sleeves and nozzles
Star stations 11 and 12:no function (optional component sensor)
1-12segment numbering