24 ’Display e mpty trac ks with comp onent ve rification’ ↑ UM 4.3.1 If the Component ve rification with barcode option ha s been config ured and activat ed, the f ollowing menu will appe ar: Within this menu, loc ations…

100%1 / 44
23
Feeders’ menu
The Feeders menu has four submenus for querying or checking the status
UM 4.3 of all feeder modules:
Displaying empty tracks and setting them full
Omit components. (This menu can only be accessed from the ’Line engi-
neer’ operator control level or higher).
Displaying magazines and changing inventory levels
Displaying and vibrating linear feeders
With the 80F placement machine there is an additional submenu, Func-
tions with the wafflepack changer.
’Display and refill empty tracks’ menu
The empty tracks of feeder modules are displayed in this menu. After fill-
ing, you can set the tracks to full.
UM 4.3.1 Depending on the option which has been activated, the following sub-
menus will be called:
’Display empty tracks without component verification’
When you click on the button for location 1, 2, 3 or 4, the entire location
which you selected will be set to full.
When you select a particular feeder module in the list section and then
click on the Selected track button, the individual track will be set to full.
24
’Display empty tracks with component verification’
UM 4.3.1 If the Component verification with barcode option has been configured
and activated, the following menu will appear:
Within this menu, locations 1 to 4 or individual tracks which have been
given a barcode
cannot
be set to full. Apart from displaying the empty
tracks, this menu also allows to individually set to full those empty tracks
which have not been provided with a barcode. Tracks which do not have a
component barcode are indicated by a dash in the CO-BC column. The
Selected track button is activated here.
’Display linear feeder and vibrate’ menu
When you have filled a linear feeder, you can use this menu to select it
and turn vibration on.
Select the linear feeder from the list.
Click on the Vibrate on button. The arrow in the Vibrate column shows that
the module is being vibrated.
You can stop vibration by clicking on the Vibrate off button.
UM 4.3.3
25
’Single functions - Gantries 1/2’ menu
UM 5.2 The Single function menu for gantries 1 and 2 are identical.
Only personnel with the corresponding training and qualifi-
cations are permitted to access the Single functions Gantry X (X = 1, 2)
menu since improper treatment of the machine may result in serious phys-
ical injury and considerable damage to property.
The Single functions Gantry X menu has the following submenus:
Gantry functions
Revolver head functions
Vacuum test revolver head
Nozzle offset revolver head
Nozzle configuration
Nozzle-changer configuration revolver head (if this option has been
installed and configured)
’Gantry functions’ menu
NOTE
All movement functions of the x and y gantry axes have to be initiated with
the Start button. You will be requested to do so by the on-screen display
’Press start key’.
If protective covers are still open, you will be asked to close them.
Go to set-up position Go to this position if you wish to refill or replace feeder modules.
Go to service pos’n Go to this position when you want to carry out servicing of the placement
head or gantry.
Go to waiting pos’n Move the gantry to this position if the gantry is not required.
Go to zero pulse The gantry travels until it reaches the zero pulse.
Gantry reference run The gantry carries out a reference run.