SIPLACE S-23 HM User Manual - 第28页

28 ’Nozzle configu ration revolver hea d’ menu Within the Nozzle co nfiguration re volver he ad menu you can view the ↑ UM 5.2.5 no zzle configur ation and check nozzle s. If a nozzle changer has been installed you ca n …

100%1 / 44
27
’Vacuum test revolver head’ menu
When this function is executed the revolver head performs a head refer-
UM 5.2.3 ence run. At the same time the vacuum values of all nozzles at the pick-up
position are measured with the nozzles both closed and open.
The values are then displayed in the list.
’Nozzle offset revolver head’ menu
When this function is executed you will be asked to press the start button
UM 5.2.4 by a screen message. The gantry will then travel over a measurement
position on the board conveyor. Here the z heights of all segments are
measured and displayed on the screen. The gantry then returns to its ini-
tial waiting position.
28
’Nozzle configuration revolver head’ menu
Within the Nozzle configuration revolver head menu you can view the
UM 5.2.5 nozzle configuration and check nozzles. If a nozzle changer has been
installed you can change the nozzles with the aid of this menu.
NOTE
Nozzle-changing is only possible with the prespecified cluster and pre-
specified setup.
List field The nozzle configuration is displayed with the programmed and actual val-
ues. Nozzles marked with an arrow in the ’To change’ column have to be
changed. The cyan bar indicates that the corresponding nozzle is in the
changing position.
Revolver head The arrow shows the changing position for the nozzle in question.
diagram
Star step Each time you click on this button the star is cycled forward one position.
Confirm Carry out the following actions in turn.
Cycle the nozzle marked with an arrow into the changing position.
Change the nozzle.
Click on the Confirm button. The display of the programmed and actual
values in the lists field has to be identical.
The following functions can only be executed if a nozzle changer has
been installed:
One nozzle When ’One nozzle’ is activated, the ’Return’, ’Pick up’, ’Remove’ and
’Replace’ functions will only be carried out for the selected nozzle. If you
click on one of these functions, an input box will appear so that you can
enter the segment number. The default value that appears in the input box
is the number of the segment currently at the change position. It is indi-
cated by cyan-colored arrow.
Click on OK to execute the function.
29
Return all nozzles All nozzles are returned to the magazine of the nozzle changer.
Pick up all nozzles The revolver head picks up all nozzles from the nozzle magazine.
Remove all nozzles All of the nozzles in the revolver head are discarded into the rejects con-
tainer.
’Nozzle-changer configuration revolver head’ menu
UM 5.2.6 Within this menu you can
find out the nozzle types of the individual magazines
check nozzles and
change nozzles.
Magazine: Magazine number, maximum 7
Number: Number of nozzles in the magazine
Actual: Setup currently in the nozzle changer
Preset: Setup specified by the line computer
Arrow: If preset and actual values differ, this will be indicated by an arrow.
Lock. op./close You can open or close the closing plate of the selected nozzle changer
magazine in order to fill the nozzle changer magazine manually.
Refill: Refill the magazine with new nozzles of the same type and click on ’Refill’.
The fill level is updated.
NOTE
Make sure that the nozzle magazines are kept full.
Confirm magazine: Set up the nozzles as required in the magazine indicated by an arrow.
Move the cyan bar over the corresponding line in the list field.
Click on ‘Confirm magaz.’. The desired and actual values must agree.