SIPLACE S-23 HM User Manual - 第29页
29 Return all no zzles All nozzles are returned t o the mag azine of the nozzle ch anger . Pick up all no zzles The revolve r head pi cks up all noz zles from the nozzle ma gazine. Remove all n ozzles All of the no zzles…

28
’Nozzle configuration revolver head’ menu
Within the Nozzle configuration revolver head menu you can view the
↑ UM 5.2.5 nozzle configuration and check nozzles. If a nozzle changer has been
installed you can change the nozzles with the aid of this menu.
NOTE
Nozzle-changing is only possible with the prespecified cluster and pre-
specified setup.
List field The nozzle configuration is displayed with the programmed and actual val-
ues. Nozzles marked with an arrow in the ’To change’ column have to be
changed. The cyan bar indicates that the corresponding nozzle is in the
changing position.
Revolver head The arrow shows the changing position for the nozzle in question.
diagram
Star step Each time you click on this button the star is cycled forward one position.
Confirm Carry out the following actions in turn.
● Cycle the nozzle marked with an arrow into the changing position.
● Change the nozzle.
● Click on the Confirm button. The display of the programmed and actual
values in the lists field has to be identical.
The following functions can only be executed if a nozzle changer has
been installed:
One nozzle When ’One nozzle’ is activated, the ’Return’, ’Pick up’, ’Remove’ and
’Replace’ functions will only be carried out for the selected nozzle. If you
click on one of these functions, an input box will appear so that you can
enter the segment number. The default value that appears in the input box
is the number of the segment currently at the change position. It is indi-
cated by cyan-colored arrow.
● Click on OK to execute the function.

29
Return all nozzles All nozzles are returned to the magazine of the nozzle changer.
Pick up all nozzles The revolver head picks up all nozzles from the nozzle magazine.
Remove all nozzles All of the nozzles in the revolver head are discarded into the rejects con-
tainer.
’Nozzle-changer configuration revolver head’ menu
↑ UM 5.2.6 Within this menu you can
– find out the nozzle types of the individual magazines
– check nozzles and
– change nozzles.
Magazine: Magazine number, maximum 7
Number: Number of nozzles in the magazine
Actual: Setup currently in the nozzle changer
Preset: Setup specified by the line computer
Arrow: If preset and actual values differ, this will be indicated by an arrow.
Lock. op./close You can open or close the closing plate of the selected nozzle changer
magazine in order to fill the nozzle changer magazine manually.
Refill: Refill the magazine with new nozzles of the same type and click on ’Refill’.
The fill level is updated.
NOTE
Make sure that the nozzle magazines are kept full.
Confirm magazine: Set up the nozzles as required in the magazine indicated by an arrow.
– Move the cyan bar over the corresponding line in the list field.
– Click on ‘Confirm magaz.’. The desired and actual values must agree.

30
’Single functions PCB transport 1’ menu
↑ UM 5.3 This menu is used for checking and setting the function modules of the
PCB conveyor. If the twin conveyor option is installed, the Single functions
PCB transport 2 menu will be activated. The same functions as with PCB
transport 1 will then be available to you.
NOTE
To move the gantries, close the covers and then press the start button. All
gantry and head axes will move at low speed.
PCB The PCB is transported from the input conveyor onto the center conveyor
to center conveyor and then stopped and clamped.
PCB The PCB is transported from the center conveyor onto the output
to output conveyor conveyor.
The following menu items behave like a toggle switch when clicked on.
Ceramic substrate Click on the Ceramic substrate centering button and the substrate
centering (option) centering clamp will be activated or deactivated.
Actuate clamping Click on the Actuate clamping button and the clamp will be activated or
deactivated.
Actuate stopper Click on the Actuate stopper button and the stopper will be moved in and
out of position.
Sensor You can use this menu item to interrogate the states of the ultrasonic
Input/center/output beros in the input, center and output conveyors:
Refresh 1 = has responded
0 = has not responded
Conveyor - Select different speeds for the conveyor width adjustment.
high speed
NOTE
Make sure that there are no boards on the conveyor belts. The input belt
runs at high speed only.
Conveyor - On This starts the conveyor belts.