37 ● Open the h orizontal tens ioners (item 1 1) ● Pull the two actuatin g tubes (item 6 ) towards you at the same time and lift up the brac ket (item 7) to lock the raised co mponent table bed in its top end positio n. …

36
Undocking the component table
a
Communication interface connector
s Power supply connector for the component table
d Compressed air connection
f Component table bed
g Button for raising and lowering the component table bed
h Actuating tube
j Fold-down bracket
k
Holes for the centering pins
l Centering pins
; Contact surfaces for the slide rails of the component table
A Horizontal tensioners
● Click on the
STOP PROCESSING PCB icon in the MAIN VIEW menu.
● The PCB in progress will be completed. The icons of the SINGLE FUNC-
TIONS menu will then be activated.
● Click on the desired SINGLE FUNCTIONS GANTRY X icon (gantry 1
or 2).
● Click on the GANTRY FUNCTIONS icon.
● From this menu, click on the GO TO SET-UP POSITION button.
● The selected placement head will move across the PCB transport to pre-
vent it being damaged when the component table is changed.
● Open protective cover of the selected gantry.
● Open the side screens.

37
● Open the horizontal tensioners (item 11)
● Pull the two actuating tubes (item 6) towards you at the same time and lift
up the bracket (item 7) to lock the raised component table bed in its top
end position.
● Hold down the button (item 5) for raising the component table bed (item 4)
until the component table bed reaches its top end position.
● Unplug the component table power cable (item 2).
● Unplug the component table control cable (item 1).
● Disconnect the compressed air supply (item 3).
● Remove the component table.
Docking the component table
WARNING
Check that the placement head is outside the range of the component
table.
CAUTION
When docking the component table, ensure that the table bed is in its top
end position and the bracket (item 7) is folded up.
● Cut off the empty tapes for the feeder modules.
● Make sure that the contact surface (item 10) for the component table bed
is clean.
● CAREFULLY push the component table into the placement system.
● Connect the compressed air supply (item 3).
● Plug in the control cable (item 1).
● Plug in the power cable (item 2) for the component table.
● Pull the two actuating tubes (item 6) towards you at the same time and
then lower the bracket (item 7) in order to be able to lower the component
table bed.
● Check that the centEring holes in the component table bed lie precisely
over the centering pins of the placement system.
● Hold down the button (item 5) until the component table bed reaches its
top end position.
● Release the button and the component table bed will descend.
● Ensure that the centring pins engage in the centring holes in the compo-
nent table bed and that the component table bed is fully lowered.
● Fold up the bracket (item 7) of the component table.
● Lock the two horizontal tensioners (item 11).
● Close the side screens and protective cover.
● Press the Start button to start the placement system.