2-36 2 Board Explorer 5 Please set the [Block F id C onvert Mode] and [L ocal F id C onv ert Mode]. • Convert Mode : Description • Not Convert : It does not Convert. • Local Fiducial : It convert to Inspector’s STEP that…

100%1 / 238
2-35
2
Board Explorer
3
Set up conveyor on the fixed side.
Select front side when the conveyor of the mounter is fixed at front side: select rear side when fixed at
rear side.
Setting of conveyor on the fixed side
642C4-S0-10
4
Set up board origin references X and Y.
Set X=5.000 and Y=5.000 in normal use.
If the coordination of the converted Inspection program is misaligned, correct the value within a range
of -999.999 to 999.999.
Setting of board origin references X and Y
642C5-S0-10
2-36
2
Board Explorer
5
Please set the [Block Fid Convert Mode] and [Local Fid Convert Mode].
• Convert Mode : Description
• Not Convert : It does not Convert.
• Local Fiducial : It convert to Inspector’s STEP that status is “Fiducial”.
[Block Fid Convert Mode] and [Local Fid Convert Mode]
642D6-S0-00
6
If you want to convert to FAST, please check on the “FAST”.
On the “FAST”
642D7-S0-00
2-37
2
Board Explorer
7
Double-click an inspector name or click the [Change] button to change an
inspector name.
Change of inspector name
642C6-S0-10
Up to five inspectors can be set.
The inspector name set here will be indicated in the "Board data conversion" menu.
“Board data conversion” menu
642C7-S0-00