sh030106u.pdf - 第148页

5. PARAMETE RS 5 - 3 5.1.2 Gai n/filter set ting p arameter s ([Pr . PB_ _ ]) No. Symbol Name Initial value Unit Operation mode Standard Full. Lin. D.D. PB01 FILT Adaptive tuning mode (adaptive filter II) 0000h PB02 VRFT…

100%1 / 710
5. PARAMETERS
5 - 2
5.1.1 Basic setting parameters ([Pr. PA_ _ ])
No. Symbol Name
Initial
value
Unit
Operation
mode
Standard
Full.
Lin.
D.D.
PA01 **STY Operation mode 1000h
PA02 **REG Regenerative option 0000h
PA03 *ABS Absolute position detection system 0000h
PA04 *AOP1 Function selection A-1 2000h
PA05 For manufacturer setting 10000
PA06 1
PA07 1
PA08 ATU Auto tuning mode 0001h
PA09 RSP Auto tuning response 16
PA10 INP In-position range 1600 [pulse]
PA11 For manufacturer setting 1000.0
PA12 1000.0
PA13 0000h
PA14 *POL Rotation direction selection/travel direction selection 0
PA15 *ENR Encoder output pulses 4000 [pulse/rev]
PA16 *ENR2 Encoder output pulses 2 1
PA17 **MSR Servo motor series setting 0000h
PA18 **MTY Servo motor type setting 0000h
PA19 *BLK Parameter writing inhibit 00ABh
PA20 *TDS Tough drive setting 0000h
PA21 *AOP3 Function selection A-3 0001h
PA22 **PCS Position control composition selection 0000h
PA23 DRAT Drive recorder arbitrary alarm trigger setting 0000h
PA24 AOP4 Function selection A-4 0000h
PA25 OTHOV One-touch tuning - Overshoot permissible level 0 [%]
PA26 *AOP5 Function selection A-5 0000h
PA27 For manufacturer setting 0000h
PA28 0000h
PA29 0000h
PA30 0000h
PA31 0000h
PA32 0000h
5. PARAMETERS
5 - 3
5.1.2 Gain/filter setting parameters ([Pr. PB_ _ ])
No. Symbol Name
Initial
value
Unit
Operation
mode
Standard
Full.
Lin.
D.D.
PB01 FILT Adaptive tuning mode (adaptive filter II) 0000h
PB02 VRFT
Vibration suppression control tuning mode (advanced vibration
suppression control II)
0000h
PB03 TFBGN Torque feedback loop gain 18000 [rad/s]
PB04 FFC Feed forward gain 0 [%]
PB05 For manufacturer setting 500
PB06 GD2 Load to motor inertia ratio/load to motor mass ratio 7.00 [Multiplier]
PB07 PG1 Model loop gain 15.0 [rad/s]
PB08 PG2 Position loop gain 37.0 [rad/s]
PB09 VG2 Speed loop gain 823 [rad/s]
PB10 VIC Speed integral compensation 33.7 [ms]
PB11 VDC Speed differential compensation 980
PB12 OVA Overshoot amount compensation 0 [%]
PB13 NH1 Machine resonance suppression filter 1 4500 [Hz]
PB14 NHQ1 Notch shape selection 1 0000h
PB15 NH2 Machine resonance suppression filter 2 4500 [Hz]
PB16 NHQ2 Notch shape selection 2 0000h
PB17 NHF Shaft resonance suppression filter 0000h
PB18 LPF Low-pass filter setting 3141 [rad/s]
PB19 VRF11 Vibration suppression control 1 - Vibration frequency 100.0 [Hz]
PB20 VRF12 Vibration suppression control 1 - Resonance frequency 100.0 [Hz]
PB21 VRF13 Vibration suppression control 1 - Vibration frequency damping 0.00
PB22 VRF14 Vibration suppression control 1 - Resonance frequency damping 0.00
PB23 VFBF Low-pass filter selection 0000h
PB24 *MVS Slight vibration suppression control 0000h
PB25 *BOP1 Function selection B-1 0000h
PB26 *CDP Gain switching function 0000h
PB27 CDL Gain switching condition 10
[kpulse/s]/
[pulse]/
[r/min]
PB28 CDT Gain switching time constant 1 [ms]
PB29 GD2B Load to motor inertia ratio/load to motor mass ratio after gain switching 7.00 [Multiplier]
PB30 PG2B Position loop gain after gain switching 0.0 [rad/s]
PB31 VG2B Speed loop gain after gain switching 0 [rad/s]
PB32 VICB Speed integral compensation after gain switching 0.0 [ms]
PB33 VRF11B Vibration suppression control 1 - Vibration frequency after gain switching 0.0 [Hz]
PB34 VRF12B
Vibration suppression control 1 - Resonance frequency after gain
switching
0.0 [Hz]
PB35 VRF13B
Vibration suppression control 1 - Vibration frequency damping after gain
switching
0.00
PB36 VRF14B
Vibration suppression control 1 - Resonance frequency damping after
gain switching
0.00
PB37 For manufacturer setting 1600
PB38 0.00
PB39 0.00
PB40 0.00
PB41 0
PB42 0
PB43 0000h
PB44 0.00
PB45 CNHF Command notch filter 0000h
5. PARAMETERS
5 - 4
No. Symbol Name
Initial
value
Unit
Operation
mode
Standard
Full.
Lin.
D.D.
PB46 NH3 Machine resonance suppression filter 3 4500 [Hz]
PB47 NHQ3 Notch shape selection 3 0000h
PB48 NH4 Machine resonance suppression filter 4 4500 [Hz]
PB49 NHQ4 Notch shape selection 4 0000h
PB50 NH5 Machine resonance suppression filter 5 4500 [Hz]
PB51 NHQ5 Notch shape selection 5 0000h
PB52 VRF21 Vibration suppression control 2 - Vibration frequency 100.0 [Hz]
PB53 VRF22 Vibration suppression control 2 - Resonance frequency 100.0 [Hz]
PB54 VRF23 Vibration suppression control 2 - Vibration frequency damping 0.00
PB55 VRF24 Vibration suppression control 2 - Resonance frequency damping 0.00
PB56 VRF21B Vibration suppression control 2 - Vibration frequency after gain switching 0.0 [Hz]
PB57 VRF22B
Vibration suppression control 2 - Resonance frequency after gain
switching
0.0 [Hz]
PB58 VRF23B
Vibration suppression control 2 - Vibration frequency damping after gain
switching
0.00
PB59 VRF24B
Vibration suppression control 2 - Resonance frequency damping after
gain switching
0.00
PB60 PG1B Model loop gain after gain switching 0.0 [rad/s]
PB61 For manufacturer setting 0.0
PB62 0000h
PB63 0000h
PB64 0000h
5.1.3 Extension setting parameters ([Pr. PC_ _ ])
No. Symbol Name
Initial
value
Unit
Operation
mode
Standard
Full.
Lin.
D.D.
PC01 ERZ Error excessive alarm level 0
[rev]/
[mm]
PC02 MBR Electromagnetic brake sequence output 0 [ms]
PC03 *ENRS Encoder output pulse selection 0000h
PC04 **COP1 Function selection C-1 0000h
PC05 **COP2 Function selection C-2 0000h
PC06 *COP3 Function selection C-3 0000h
PC07 ZSP Zero speed 50
[r/min]/
[mm/s]
PC08 OSL Overspeed alarm detection level 0
[r/min]/
[mm/s]
PC09 MOD1 Analog monitor 1 output 0000h
PC10 MOD2 Analog monitor 2 output 0001h
PC11 MO1 Analog monitor 1 offset 0 [mV]
PC12 MO2 Analog monitor 2 offset 0 [mV]
PC13 MOSDL Analog monitor - Feedback position output standard data - Low 0 [pulse]
PC14 MOSDH Analog monitor - Feedback position output standard data - High 0
[10000 pulses]
PC15 For manufacturer setting 0
PC16 0000h
PC17 **COP4 Function selection C-4 0000h
PC18 *COP5 Function selection C-5 0000h
PC19 For manufacturer setting 0000h
PC20 *COP7 Function selection C-7 0000h