sh030106u.pdf - 第176页

5. PARAMETE RS 5 - 31 No. Sym bol Name and function Initial value [unit] Setting range PB45 CNHF Table 5.6 Notch dep th se lection Refer to t he "Name and function" c olumn. Setting value Depth [dB] Setting val…

100%1 / 710
5. PARAMETERS
5 - 30
No. Symbol Name and function
Initial
value
[unit]
Setting
range
PB45 CNHF Command notch filter
Set the command notch filter.
Refer to the
"Name and
function" column.
Setting
digit
Explanation
Initial
value
_ _ x x Command notch filter setting frequency selection
Refer to table 5.5 for the relation of setting values to frequency.
00h
_ x _ _ Notch depth selection
Refer to table 5.6 for details.
0h
x _ _ _ For manufacturer setting 0h
Table 5.5 Command notch filter setting frequency selection
Setting
value
Frequency
[Hz]
Setting
value
Frequency
[Hz]
Setting
value
Frequency
[Hz]
_ _ 0 0 Disabled _ _ 2 0 70 _ _ 4 0 17.6
_ _ 0 1 2250 _ _ 2 1 66 _ _ 4 1 16.5
_ _ 0 2 1125 _ _ 2 2 62 _ _ 4 2 15.6
_ _ 0 3 750 _ _ 2 3 59 _ _ 4 3 14.8
_ _ 0 4 562 _ _ 2 4 56 _ _ 4 4 14.1
_ _ 0 5 450 _ _ 2 5 53 _ _ 4 5 13.4
_ _ 0 6 375 _ _ 2 6 51 _ _ 4 6 12.8
_ _ 0 7 321 _ _ 2 7 48 _ _ 4 7 12.2
_ _ 0 8 281 _ _ 2 8 46 _ _ 4 8 11.7
_ _ 0 9 250 _ _ 2 9 45 _ _ 4 9 11.3
_ _ 0 A 225 _ _ 2 A 43 _ _ 4 A 10.8
_ _ 0 B 204 _ _ 2 B 41 _ _ 4 B 10.4
_ _ 0 C 187 _ _ 2 C 40 _ _ 4 C 10
_ _ 0 D 173 _ _ 2 D 38 _ _ 4 D 9.7
_ _ 0 E 160 _ _ 2 E 37 _ _ 4 E 9.4
_ _ 0 F 150 _ _ 2 F 36 _ _ 4 F 9.1
_ _ 1 0 140 _ _ 3 0 35.2 _ _ 5 0 8.8
_ _ 1 1 132 _ _ 3 1 33.1 _ _ 5 1 8.3
_ _ 1 2 125 _ _ 3 2 31.3 _ _ 5 2 7.8
_ _ 1 3 118 _ _ 3 3 29.6 _ _ 5 3 7.4
_ _ 1 4 112 _ _ 3 4 28.1 _ _ 5 4 7.0
_ _ 1 5 107 _ _ 3 5 26.8 _ _ 5 5 6.7
_ _ 1 6 102 _ _ 3 6 25.6 _ _ 5 6 6.4
_ _ 1 7 97 _ _ 3 7 24.5 _ _ 5 7 6.1
_ _ 1 8 93 _ _ 3 8 23.4 _ _ 5 8 5.9
_ _ 1 9 90 _ _ 3 9 22.5 _ _ 5 9 5.6
_ _ 1 A 86 _ _ 3 A 21.6 _ _ 5 A 5.4
_ _ 1 B 83 _ _ 3 B 20.8 _ _ 5 B 5.2
_ _ 1 C 80 _ _ 3 C 20.1 _ _ 5 C 5.0
_ _ 1 D 77 _ _ 3 D 19.4 _ _ 5 D 4.9
_ _ 1 E 75 _ _ 3 E 18.8 _ _ 5 E 4.7
_ _ 1 F 72 _ _ 3 F 18.2 _ _ 5 F 4.5
5. PARAMETERS
5 - 31
No. Symbol Name and function
Initial
value
[unit]
Setting
range
PB45 CNHF
Table 5.6 Notch depth selection
Refer to the
"Name and
function" column.
Setting
value
Depth [dB]
Setting
value
Depth [dB]
_ 0 _ _ -40.0 _ 8 _ _ -6.0
_ 1 _ _ -24.1 _ 9 _ _ -5.0
_ 2 _ _ -18.1 _ A _ _ -4.1
_ 3 _ _ -14.5 _ B _ _ -3.3
_ 4 _ _ -12.0 _ C _ _ -2.5
_ 5 _ _ -10.1 _ D _ _ -1.8
_ 6 _ _ -8.5 _ E _ _ -1.2
_ 7 _ _ -7.2 _ F _ _ -0.6
PB46 NH3 Machine resonance suppression filter 3
Set the notch frequency of the machine resonance suppression filter 3.
To enable the setting value, select "Enabled (_ _ _ 1)" of "Machine resonance suppression
filter 3 selection" in [Pr. PB47].
4500
[Hz]
10 to
4500
PB47 NHQ3 Notch shape selection 3
Set the shape of the machine resonance suppression filter 3.
Refer to the
"Name and
function" column.
Setting
digit
Explanation
Initial
value
_ _ _ x Machine resonance suppression filter 3 selection
0: Disabled
1: Enabled
0h
_ _ x _ Notch depth selection
0: -40 dB
1: -14 dB
2: -8 dB
3: -4 dB
0h
_ x _ _ Notch width selection
0: α = 2
1: α = 3
2: α = 4
3: α = 5
0h
x _ _ _ For manufacturer setting 0h
PB48 NH4 Machine resonance suppression filter 4
Set the notch frequency of the machine resonance suppression filter 4.
To enable the setting value, select "Enabled (_ _ _ 1)" of "Machine resonance suppression
filter 4 selection" in [Pr. PB49].
4500
[Hz]
10 to
4500
5. PARAMETERS
5 - 32
No. Symbol Name and function
Initial
value
[unit]
Setting
range
PB49 NHQ4 Notch shape selection 4
Set the shape of the machine resonance suppression filter 4.
Refer to the
"Name and
function" column.
Setting
digit
Explanation
Initial
value
_ _ _ x Machine resonance suppression filter 4 selection
0: Disabled
1: Enabled
When you select "Enabled" of this digit, [Pr. PB17 Shaft resonance
suppression filter] is not available.
0h
_ _ x _ Notch depth selection
0: -40 dB
1: -14 dB
2: -8 dB
3: -4 dB
0h
_ x _ _ Notch width selection
0: α = 2
1: α = 3
2: α = 4
3: α = 5
0h
x _ _ _ For manufacturer setting 0h
PB50 NH5 Machine resonance suppression filter 5
Set the notch frequency of the machine resonance suppression filter 5.
To enable the setting value, select "Enabled (_ _ _ 1)" of "Machine resonance suppression
filter 5 selection" in [Pr. PB51].
4500
[Hz]
10 to
4500
PB51 NHQ5 Notch shape selection 5
Set the shape of the machine resonance suppression filter 5.
When you select "Enabled (_ _ _ 1)" of "Robust filter selection" in [Pr. PE41], the machine
resonance suppression filter 5 is not available.
Refer to the
"Name and
function" column.
Setting
digit
Explanation
Initial
value
_ _ _ x Machine resonance suppression filter 5 selection
0: Disabled
1: Enabled
0h
_ _ x _ Notch depth selection
0: -40 dB
1: -14 dB
2: -8 dB
3: -4 dB
0h
_ x _ _ Notch width selection
0: α = 2
1: α = 3
2: α = 4
3: α = 5
0h
x _ _ _ For manufacturer setting 0h
PB52 VRF21 Vibration suppression control 2 - Vibration frequency
Set the vibration frequency for vibration suppression control 2 to suppress low-frequency
machine vibration.
To enable the setting value, set "Vibration suppression mode selection" to "3 inertia mode (_ _
_ 1)" in [Pr. PA24].
When "Vibration suppression control 2 tuning mode selection" is set to "Automatic setting (_ _
1 _)" in [Pr. PB02], this parameter will be set automatically. When "Manual setting (_ _ 2 _)" is
selected, the setting written to the parameter is used.
The setting range of this parameter varies, depending on the value in [Pr. PB07]. If a value out
of the range is set, the vibration suppression control will be disabled. Refer to section 7.1.5 for
details.
100.0
[Hz]
0.1 to
300.0