11. OPT ION S AND P ERI PHER AL EQU IPMENT 11 - 76 (1) For mai n circuit po wer supply When usi ng a fuse instead of the mo lded-c ase cir cuit b reaker, u se t he one havin g the s pecific atio ns given in this s ect io…

100%1 / 710
11. OPTIONS AND PERIPHERAL EQUIPMENT
11 - 75
11.10 Molded-case circuit breakers, fuses, magnetic contactors
CAUTION
To prevent the servo amplifier from smoke and a fire, select a molded-case circuit
breaker which shuts off with high speed.
Always use one molded-case circuit breaker and one magnetic contactor with one
servo amplifier.
POINT
For the selection when the MR-J4-_B-RJ servo amplifier is used with the DC
power supply input, refer to app. 15.4.
11. OPTIONS AND PERIPHERAL EQUIPMENT
11 - 76
(1) For main circuit power supply
When using a fuse instead of the molded-case circuit breaker, use the one having the specifications
given in this section.
Servo amplifier
Molded-case circuit breaker (Note 1) Fuse
Magnetic
contactor
(Note 2)
Frame, rated current
Voltage AC
[V]
Class Current [A]
Voltage AC
[V]
Power factor
improving reactor is
not used
Power factor
improving reactor is
used
MR-J4-10B(-RJ) 30 A frame 5 A 30 A frame 5 A
240 T
10
300
S-N10
S-T10
MR-J4-20B(-RJ) 30 A frame 5 A 30 A frame 5 A
MR-J4-40B(-RJ) 30 A frame 10 A 30 A frame 5 A 15
MR-J4-60B(-RJ) 30 A frame 15 A 30 A frame 10 A
20
MR-J4-70B(-RJ) 30 A frame 15 A 30 A frame 10 A
MR-J4-100B(-RJ)
(3-phase power
supply input)
30 A frame 15 A 30 A frame 10 A
MR-J4-100B(-RJ)
(1-phase power
supply input)
30 A frame 15 A 30 A frame 15 A 30
MR-J4-200B(-RJ) 30 A frame 20 A 30 A frame 20 A 40
S-N20
(Note 3)
S-T21
MR-J4-350B(-RJ) 30 A frame 30 A 30 A frame 30 A 70
S-N20
S-T21
MR-J4-500B(-RJ) 50 A frame 50 A 50 A frame 50 A 125
S-N35
S-T35
MR-J4-700B(-RJ) 100 A frame 75 A 60 A frame 60 A 150
S-N50
S-T50
MR-J4-11KB(-RJ) 100 A frame 100 A 100 A frame 100 A 200
MR-J4-15KB(-RJ) 125 A frame 125 A 125 A frame 125 A 250
S-N65
S-T65
MR-J4-22KB(-RJ) 225 A frame 175 A 225 A frame 175 A 350
S-N95
S-T100
MR-J4-60B4(-RJ) 30 A frame 5 A 30 A frame 5 A
480 T
10
600
S-N10
S-T10
MR-J4-100B4(-RJ) 30 A frame 10 A 30 A frame 5 A 15
MR-J4-200B4(-RJ) 30 A frame 15 A 30 A frame 10 A 25
MR-J4-350B4(-RJ) 30 A frame 20 A 30 A frame 15 A 35
S-N20
(Note 3)
S-T21
MR-J4-500B4(-RJ) 30 A frame 20 A 30 A frame 20 A 50
MR-J4-700B4(-RJ) 30 A frame 30 A 30 A frame 30 A 65
S-N20
S-T21
MR-J4-11KB4(-RJ) 50 A frame 50 A 50 A frame 50 A 100
S-N25
S-T35
MR-J4-15KB4(-RJ) 60 A frame 60 A 60 A frame 60 A 150
S-N35
S-T35
MR-J4-22KB4(-RJ) 100 A frame 100 A 100 A frame 100 A 175
S-N50
S-T50
MR-J4-10B1(-RJ) 30 A frame 5 A 30 A frame 5 A
240 T
10
300
S-N10
S-T10
MR-J4-20B1(-RJ) 30 A frame 10 A 30 A frame 10 A 15
MR-J4-40B1(-RJ) 30 A frame 15 A 30 A frame 10 A 20
Note 1. When havin
g
the servo amplifier compl
y
with the IEC/EN/UL/CSA standard, refer to app. 4.
2. Use a magnetic contactor with an operation delay time (interval between current being applied to the coil until closure of
contacts
)
of 80 ms or less.
3. S-N18 can be used when auxiliar
y
contact is not required.
11. OPTIONS AND PERIPHERAL EQUIPMENT
11 - 77
The Type E Combination motor controller can also be used instead of a molded-case circuit breaker.
Servo amplifier
Rated input
voltage AC [V]
Input phase
Type E Combination motor controller
SCCR
[kA]
Model
Rated
voltage
AC [V]
Rated current
[A]
(Heater design)
MR-J4-10B(-RJ)
200 to 240 3-phase
MMP-T32
240
1.6
50
MR-J4-20B(-RJ) 2.5
MR-J4-40B(-RJ) 4
MR-J4-60B(-RJ) 6.3
MR-J4-70B(-RJ) 6.3
MR-J4-100B(-RJ) 8
MR-J4-200B(-RJ) 18
MR-J4-350B(-RJ) 25
25
MR-J4-500B(-RJ) 32
MR-J4-60B4(-RJ)
380 to 480 3-phase 480Y/277
2.5
50
MR-J4-100B4(-RJ) 4
MR-J4-200B4(-RJ) 8
MR-J4-350B4(-RJ) 13
MR-J4-500B4(-RJ) 18
MR-J4-700B4(-RJ) 25 25
(2) For control circuit power supply
When the wiring for the control circuit power supply (L11/L21) is thinner than that for the main circuit
power supply (L1/L2/L3), install an overcurrent protection device (molded-case circuit breaker or fuse) to
protect the branch circuit.
Servo amplifier
Molded-case circuit breaker (Note) Fuse (Class T) Fuse (Class K5)
Frame, rated current Voltage AC [V] Current [A] Voltage AC [V] Current [A] Voltage AC [V]
MR-J4-10B(-RJ)
MR-J4-20B(-RJ)
MR-J4-40B(-RJ)
MR-J4-60B(-RJ)
MR-J4-70B(-RJ)
MR-J4-100B(-RJ)
MR-J4-200B(-RJ) 30 A frame 5 A 240 1 300 1 250
MR-J4-350B(-RJ)
MR-J4-500B(-RJ)
MR-J4-700B(-RJ)
MR-J4-11KB(-RJ)
MR-J4-15KB(-RJ)
MR-J4-22KB(-RJ)
MR-J4-60B4(-RJ)
MR-J4-100B4(-RJ)
MR-J4-200B4(-RJ)
MR-J4-350B4(-RJ)
MR-J4-500B4(-RJ) 30 A frame 5 A 480 1 600 1 600
MR-J4-700B4(-RJ)
MR-J4-11KB4(-RJ)
MR-J4-15KB4(-RJ)
MR-J4-22KB4(-RJ)
MR-J4-10B1(-RJ)
MR-J4-20B1(-RJ) 30 A frame 5 A 240 1 300 1 250
MR-J4-40B1(-RJ)
Note. When havin