17. APPLICATIO N OF FUNCTIONS 17 - 28 2) Ampli fier co mmand met hod Make one- touch tu ning as f ollows . Start Startup of the system Movement to tuning start position One-touch tuning start, mode selection Input of per…

17. APPLICATION OF FUNCTIONS
17 - 27
The following parameters are set automatically with one-touch tuning. Also, "Gain adjustment mode
selection" in [Pr. PA08] will be "2 gain adjustment mode 2 (_ _ _ 4)" automatically. Other parameters will
be set to an optimum value depending on the setting of [Pr. PA09 Auto tuning response].
Table 17.5 List of parameters automatically set with one-touch tuning
Parameter Symbol Name Parameter Symbol Name
PA08 ATU Auto tuning mode PB18 LPF Low-pass filter setting
PA09 RSP Auto tuning response
PB19 VRF11
Vibration suppression control 1 -
Vibration frequency
PB01 FILT Adaptive tuning mode (adaptive filter II)
PB02 VRFT
Vibration suppression control tuning
mode (advanced vibration suppression
control II)
PB20 VRF12
Vibration suppression control 1 -
Resonance frequency
PB21 VRF13
Vibration suppression control 1 -
Vibration frequency damping
PB06 GD2 Load to motor inertia ratio
PB07 PG1 Model loop gain
PB22 VRF14
Vibration suppression control 1 -
Resonance frequency damping
PB08 PG2 Position loop gain
PB09 VG2 Speed loop gain PB23 VFBF Low-pass filter selection
PB10 VIC Speed integral compensation PX17 NH3 Machine resonance suppression filter 3
PB12 OVA Overshoot amount compensation PX18 NHQ3 Notch shape selection 3
PB13 NH1 Machine resonance suppression filter 1 PX19 NH4 Machine resonance suppression filter 4
PB14 NHQ1 Notch shape selection 1 PX20 NHQ4 Notch shape selection 4
PB15 NH2 Machine resonance suppression filter 2 PX22 NHQ5 Notch shape selection 5
PB16 NHQ2 Notch shape selection 2 PX31 XOP4 Function selection X-4
PB17 NHF Shaft resonance suppression filter
(a) One-touch tuning flowchart
1) User command method
Make one-touch tuning as follows.
Start
Startup of the system
Operation
One-touch tuning start,
mode selection
Response mode selection
One-touch tuning execution
One-touch tuning completion
Tuning result check
One-touch tuning in progress
End
Start a system referring to chapter 4.
Rotate the servo motor by a servo system controller. (In the user command method, the one-
touch tuning cannot be executed if the servo motor is not operating.)
Start one-touch tuning of MR Configurator2, and select "User command method".
Select a response mode (High mode, Basic mode, and Low mode) in the one-touch tuning
window of MR Configurator2.
Click "Start" during servo motor driving to execute one-touch tuning.
Gains and filters will be adjusted automatically. During processing of tuning, the tuning progress
will be displayed in % in MR Configurator2.
When one-touch tuning is completed normally, the parameters described in table 17.5 will be
set automatically.
When the tuning is not completed normally, the tuning error will be displayed. (Refer to (4) (b) 5)
in this section.))
Check the tuning result.
When the tuning result is not satisfactory, you can return the parameter to the value before the
one-touch tuning or the initial value. (Refer to (4) (b) 8) in this section.))

17. APPLICATION OF FUNCTIONS
17 - 28
2) Amplifier command method
Make one-touch tuning as follows.
Start
Startup of the system
Movement to tuning start position
One-touch tuning start,
mode selection
Input of permissible
travel distance
Response mode selection
One-touch tuning execution
One-touch tuning completion
Tuning result check
One-touch tuning in progress
Controller reset
Servo amplifier power cycling
End
Start a system referring to chapter 4.
Move the moving part to the center of a movable range.
Start one-touch tuning of MR Configurator2, and select "Amplifier command method".
In the one-touch tuning window of MR Configurator2, input a maximum travel distance to move
the moving part at one-touch tuning.
Select a response mode (High mode, Basic mode, and Low mode) in the one-touch tuning
window of MR Configurator2.
While the servo motor is stopped, click "Start" to start one-touch tuning. After the tuning is
started, the servo motor will reciprocate automatically. Executing one-touch tuning during servo
motor rotation will cause an error. After one-touch tuning is executed using the amplifier
command method, control will not be performed by commands from the controller.
Gains and filters will be adjusted automatically. During processing of tuning, the tuning progress
will be displayed in % in MR Configurator2.
One-touch tuning will be completed automatically after the tuning. When one-touch tuning is
completed normally, the parameters described in table 17.5 will be updated automatically.
When the tuning is not completed normally, the tuning error will be displayed. (Refer to (4) (b) 5)
in this section.))
Check the tuning result.
When the tuning result is not satisfactory, you can return the parameter to the value before the
one-touch tuning or the initial value. (Refer to (4) (b) 8) in this section.))
After executing the one-touch tuning, resetting the controller or cycling the power of the servo
amplifier returns to the state in which control is performed from the controller.

17. APPLICATION OF FUNCTIONS
17 - 29
(b) Display transition and operation procedure of one-touch tuning
1) Command method selection
Select a command method from two methods in the one-touch tuning window of MR
Configurator2.
a)
b)