17. APPLICATIO N OF FUNCTIONS 17 - 57 (7) Tough dr ive func tion POINT Set ena ble/disa ble of the to ugh driv e functio n with [ Pr. PX25 T ough drive setting]. (Refer to (2) in this s ection.) This funct ion makes the …

100%1 / 710
17. APPLICATION OF FUNCTIONS
17 - 56
3) When the gain switching time constant is disabled
a) Switching time constant disabled was selected.
The gain switching time constant is disabled. The time constant is enabled at gain return.
The following example shows for [Pr. PB26 (CDP)] = 0103, [Pr. PB27 (CDL)] = 100 [pulse],
and [Pr. PB28 (CDT)] = 100 [ms].
Command pulses
Droop pulses
+100 pulses
-100 pulses
0Droop pulses [pulse]
Switching time constant
disabled
Switching at 0 ms
After-switching gain
Before-switching gain
Switching at [Pr. PB28 (CDT)] = 100 [ms] only when gain switching off (when returning)
CDT = 100 ms
63.4%
Switching at 0 ms
After-switching gain
Gain switching
b) Return time constant disabled was selected.
The gain switching time constant is enabled. The time constant is disabled at gain return.
The following example shows for [Pr. PB26 (CDP)] = 0201, [Pr. PB27 (CDL)] = 0, and [Pr.
PB28 (CDT)] = 100 [ms].
ONCDP (Gain switching)
After-switching gain
Before-switching gain
Switching at [Pr. PB28 (CDT)] = 100 [ms] only when gain switching on (when switching)
CDT = 100 ms
Return time constant disabled
Switching at 0 ms
OFF OFF
63.4%
Gain switching
17. APPLICATION OF FUNCTIONS
17 - 57
(7) Tough drive function
POINT
Set enable/disable of the tough drive function with [Pr. PX25 Tough drive
setting]. (Refer to (2) in this section.)
This function makes the equipment continue operating even under the condition that an alarm occurs.
The vibration tough drive function and instantaneous power failure tough drive function are available with
the J3 extension function.
(a) Vibration tough drive function
This function prevents vibration by resetting a filter instantaneously when machine resonance occurs
due to varied vibration frequency caused by machine aging.
To reset the machine resonance suppression filters with the function, [Pr. PB13 Machine resonance
suppression filter 1] and [Pr. PB15 Machine resonance suppression filter 2] should be set in
advance.
Set [Pr. PB13] and [Pr. PB15] as follows.
1) One-touch tuning execution (Refer to (4) in this section.)
2) Manual setting (Refer to (2) in this section.)
The vibration tough drive function operates when a detected machine resonance frequency is within
±30% for a value set in [Pr. PB13 Machine resonance suppression filter 1] or [Pr. PB15 Machine
resonance suppression filter 2].
To set a detection level of the function, set sensitivity in [Pr. PX26 Vibration tough drive - Oscillation
detection level].
POINT
Resetting [Pr. PB13] and [Pr. PB15] by the vibration tough drive function is
performed constantly. However, the number of write times to the EEPROM is
limited to once per hour.
The vibration tough drive function does not reset [Pr. PX17 Machine resonance
suppression filter 3], [Pr. PX19 Machine resonance suppression filter 4], and [Pr.
PX21 Machine resonance suppression filter 5].
The vibration tough drive function does not detect a vibration of 100 Hz or less.
17. APPLICATION OF FUNCTIONS
17 - 58
The following shows the function block diagram of the vibration tough drive function.
The function detects machine resonance frequency and compares it with [Pr. PB13] and [Pr. PB15], and
reset a machine resonance frequency of a parameter whose set value is closer.
Filter Setting parameter Precaution
Parameter that is
reset with vibration
tough drive function
Machine resonance
suppression filter 1
PB01/PB13/PB14
The filter can be set automatically with
"Filter tuning mode selection" in [Pr.
PB01].
PB13
Machine resonance
suppression filter 2
PB15/PB16 PB15
Machine resonance
suppression filter 3
PX17/PX18
Machine resonance
suppression filter 4
PX19/PX20 Enabling the machine resonance
suppression filter 4 disables the shaft
resonance suppression filter.
Using the shaft resonance suppression
filter is recommended because it is
adjusted properly depending on the
usage situation.
The shaft resonance suppression filter is
enabled for the initial setting.
Machine resonance
suppression filter 5
PX21/PX22
Enabling the robust filter disables the
machine resonance suppression filter 5.
The robust filter is disabled for the initial
setting.
Command
pulse train
Command
filter
Encoder
Servo motor
PWM
M
Load
+
-
Machine
resonance
suppression
filter 1
[Pr. PB13] [Pr. PB15] [Pr. PX17]
Machine
resonance
suppression
filter 2
Machine
resonance
suppression
filter 3
Machine
resonance
suppression
filter 4
Machine
resonance
suppression
filter 5
Shaft
resonance
suppression
filter
Robust filter
[Pr. PX19]
[Pr. PX21]
[Pr. PB17]
[Pr. PX20] [Pr. PX31]
Updates the parameter
whose setting is the
closest to the machine
resonance frequency.
Vibration tough drive
Torque
ALM
(Malfunction)
WNG
(Warning)
MTTR
(During tough drive)
ON
OFF
[Pr. PX26 Vibration tough drive - Oscillation detection level]
Detects the machine resonance and reconfigures the filter automatically.
During tough drive (MTTR) is not turned on in the vibration tough drive function.
ON
OFF
ON
OFF
5 s