3. SIGNALS AND WIRING
3 - 10
3.1.2 400 V class
(1) MR-J4-60B4(-RJ) to MR-J4-350B4(-RJ)
(Note 7)
MC
ALM
DOCOM
CN3
(Note 5)
(Note 4)
Malfunction
RA1
L1
L2
L3
P3
P4
P+
L11
L21
N-
D
C
U
V
W
(Note 1)(Note 10)
(Note 2)
(Note 14)
CNP1
CNP3
CNP2
U
V
W
M
Motor
CN2
(Note 6)
(Note 11)
(Note 11)
(Note 4)
Malfunction
RA1
OFF
MC
ON
MC
SK
CN3
(Note 5) Forced stop 2
EM2
DICOM
CN8
(Note 9)
Short-circuit connector
(Packed with the servo amplifier)
(Note 8)
Main circuit power supply
MCCB
24 V DC (Note 13)
24 V DC (Note 13)
3-phase
380 V AC to
480 V AC
(Note 12)
Step-down
transformer
Emergency stop switch
Servo amplifier Servo motor
Encoder
(Note 3)
Encoder cable
Note 1. Between P3 and P4 is connected by default. When using the power factor improving DC reactor, remove the short bar
between P3 and P4. Refer to section 11.11 for details. Additionally, a power factor improving DC reactor and power factor
improvin
g
AC reactor cannot be used simultaneousl
y
.
2.
A
lwa
y
s connect between P+ and D terminals
(
factor
y
-wired
)
. When usin
g
the re
g
enerative option, refer to section 11.2.
3. For the encoder cable, use of the option cable is recommended. For selecting cables, refer to "Servo Motor Instruction
Manual
(
Vol. 3
)
".
4. If ALM (Malfunction) output is disabled with the parameter, configure up the power supply circuit which switches off the
ma
g
netic contactor after detection of alarm occurrence on the controller side.
5. This dia
g
ram shows sink I/O interface. For source I/O interface, refer to section 3.8.3.
6. For connectin
g
servo motor power wires, refer to "Servo Motor Instruction Manual
(
Vol. 3
)
".
7. Use a magnetic contactor with an operation delay time (interval between current being applied to the coil until closure of
contacts) of 80 ms or less. Depending on the main circuit voltage and operation pattern, bus voltage decreases, and that
may cause the forced stop deceleration to shift to the dynamic brake deceleration. When dynamic brake deceleration is not
required, slow the time to turn off the ma
g
netic contactor.
8. Configure a circuit to turn off EM2 when the main circuit power is turned off to prevent an unexpected restart of the servo
amplifier.
9. When not usin
g
the STO function, attach the short-circuit connector came with a servo amplifier.
10. When wires used for L11 and L21 are thinner than wires used for L1, L2, and L3, use a molded-case circuit breaker. (Refer
to section 11.10.
)
11. Connectin
g
a servo motor for different axis to U, V, W, or CN2 of the servo amplifier ma
y
cause a malfunction.
12. Stepdown transformer is required when the coil volta
g
e of the ma
g
netic contactor is 200 V class.
13. The illustration of the 24 V DC power supply is divided between input signal and output signal for convenience. However,
the
y
can be confi
g
ured b
y
one.
14. Do not
g
round L11 and L21.

3. SIGNALS AND WIRING
3 - 11
(2) MR-J4-500B4(-RJ)/MR-J4-700B4(-RJ)
(Note 5)
(Note 4)
Malfunction
(Note 5) Forced stop 2
C
P+
L11
L21
P3
P4
N-
(Note 1)
(Note 14)
(Note 7)
MC
L1
L2
L3
U
V
W
(Note 2)
U
V
W
M
Motor
CN2
(Note 6)
(Note 4)
Malfunction
RA1
OFF
MC
ON
MC
SK
CN8
MCCB
(Note 10)
(Note 11)
(Note 11)
ALM
DOCOM
CN3
RA1
CN3
EM2
DICOM
24 V DC (Note 13)
24 V DC (Note 13)
(Note 12)
Step-down
transformer
3-phase
380 V AC to
480 V AC
Emergency stop switch
Servo amplifier Servo motor
Built-in
regenerative
resistor
(Note 3)
Encoder cable
Encoder
(Note 8)
Main circuit power supply
(Note 9)
Short-circuit connector
(Packed with the servo amplifier)
Note 1. Between P3 and P4 is connected by default. When using the power factor improving DC reactor, remove the short bar
between P3 and P4. Refer to section 11.11 for details. Additionally, a power factor improving DC reactor and power factor
improvin
g
AC reactor cannot be used simultaneousl
y
.
2. When usin
g
the re
g
enerative option, refer to section 11.2.
3. For the encoder cable, use of the option cable is recommended. For selecting cables, refer to "Servo Motor Instruction
Manual
(
Vol. 3
)
".
4. If ALM (Malfunction) output is disabled with the parameter, configure up the power supply circuit which switches off the
ma
g
netic contactor after detection of alarm occurrence on the controller side.
5. This dia
g
ram shows sink I/O interface. For source I/O interface, refer to section 3.8.3.
6. For connectin
g
servo motor power wires, refer to "Servo Motor Instruction Manual
(
Vol. 3
)
".
7. Use a magnetic contactor with an operation delay time (interval between current being applied to the coil until closure of
contacts) of 80 ms or less. Depending on the main circuit voltage and operation pattern, bus voltage decreases, and that
may cause the forced stop deceleration to shift to the dynamic brake deceleration. When dynamic brake deceleration is not
required, slow the time to turn off the ma
g
netic contactor.
8. Configure a circuit to turn off EM2 when the main circuit power is turned off to prevent an unexpected restart of the servo
amplifier.
9. When not usin
g
the STO function, attach the short-circuit connector came with a servo amplifier.
10. When wires used for L11 and L21 are thinner than wires used for L1, L2, and L3, use a molded-case circuit breaker. (Refer
to section 11.10.
)
11. Connectin
g
a servo motor for different axis to U, V, W, or CN2 of the servo amplifier ma
y
cause a malfunction.
12. Stepdown transformer is required when the coil volta
g
e of the ma
g
netic contactor is 200 V class.
13. The illustration of the 24 V DC power supply is divided between input signal and output signal for convenience. However,
the
y
can be confi
g
ured b
y
one.
14. Do not
g
round L11 and L21.

3. SIGNALS AND WIRING
3 - 12
(3) MR-J4-11KB4(-RJ) to MR-J4-22KB4(-RJ)
(Note 5)
(Note 4)
Malfunction
(Note 5) Forced stop 2
C
P+
L11
L21
P3
P4
N-
(Note 1)
(Note 18)
(Note 7)
MC
L1
L2
L3
U
V
W
U
V
W
M
Motor
CN2
(Note 6)
(Note 4)
Malfunction
RA1
OFF
MC
ON
MC
SK
CN8
MCCB
(Note 10)
(Note 11)
(Note 11)
(Note 13)
BU
BV
BW
MCCB
ALM
DOCOM
CN3
RA1
CN3
EM2
DICOM
24 V DC (Note 15)
24 V DC (Note 15)
3-phase
380 V AC to
4
80 V AC
(Note 12)
Step-down
transformer
(Note 2)
Emergency stop switch
Servo amplifier Servo motor
(Note 16, 17)
External
dynamic brake
(optional)
(Note 14)
Cooling fan
power supply
Cooling fan
(Note 3)
Encoder cable
Encoder
(Note 8)
Main circuit power supply
(Note 9)
Short-circuit connector
(Packed with the servo amplifier)