User Manual SIPLAC E CS 2 Operational safety Software Vers ion SR.408.xx 03/2006 U S Edition 2.4 Safe ty instructions for operating the machine 37 2.4.4 Safety instructions for openi ng or closing the protective covers T…

100%1 / 160
2 Operational safety User Manual SIPLACE CS
2.4 Safety instructions for operating the machine Software Version SR.408.xx03/2006 US Edition
36
WARNING 2
Æ Never reach into the gap between the component trolley and the placement system frame
(item 1 in Fig. 2.4 - 1
).
Æ Always check that the component trolley is docked on the placement system before connecting
or disconnecting the power cable for the component trolley at the socket on the placement sys-
tem (item 22.4 - 1
).
Æ NEVER connect the connecting cable for the component trolley to the socket on the placement
system and then operate the component trolley outside the machine via the compressed air
control unit (item 3 in Fig. 2.4 - 1).
2.4.2 Safety instructions for lowering the component table bed
WARNING DANGER OF CRUSHING 2
When lowering the component table bed, never reach into the gap between the feeders and the
used tape channel. 2
2.4.3 Safety instructions for changing the table height of component trolleys
WARNING DANGER OF CRUSHING 2
Remove all the feeders from the component table bed, before you adjust the table height of the
component trolley.
Act with considerable care during the conversion process because the table bed is very heavy.
Conversion of the component trolley to other PCB transport heights is described in Section 4.3
on
page 103. 2
User Manual SIPLACE CS 2 Operational safety
Software Version SR.408.xx 03/2006 US Edition 2.4 Safety instructions for operating the machine
37
2.4.4 Safety instructions for opening or closing the protective covers
To prevent any risk of injury when the protective covers on automatic placement machines are
opened or closed, the owner must instruct his operators to use the protective covers exactly as
specified in the following description.
DANGER OF CRUSHING THE HANDS IF THE PROTECTIVE COVERS
ARE OPENED OR CLOSED INCORRECTLY
To open or close the protective covers, take hold of the recessed grips with
both hands (see point (1) in Fig. 2.4 - 2
). This “two-handed operation” will prevent
any risk of injuring your hands. You will also avoid tilting the protective covers during opening or
closing, which would place an excessive load on the guides. 2
Fig. 2.4 - 2 Protective covers on the SIPLACE automatic placement machine
(1) Recessed grips for opening or closing the protective covers
(2) Protective cover
2 Operational safety User Manual SIPLACE CS
2.4 Safety instructions for operating the machine Software Version SR.408.xx03/2006 US Edition
38
2.4.5 Securing the placement machine to prevent it slipping
In areas with an earthquake risk, it is essential to secure the placement machine to prevent it
slipping.
Two holes for M8 bolts are provided in the machine feet for this purpose.
Æ Use the bolts to fix the placement machine to the floor as shown in the diagram below.