00194086-01 - 第44页

2 Operational safety User Manual SIPLACE CS 2.5 Safety equipment Software Version SR.408.xx03/2006 US Edition 44 2.5.3 EMERGENCY ST OP button s, protective cov er switches ... Fig. 2.5 - 4 Location of the buttons and pr …

100%1 / 160
User Manual SIPLACE CS 2 Operational safety
Software Version SR.408.xx 03/2006 US Edition 2.5 Safety equipment
43
2.5.2 Guard on the input / output belt
WARNING
The guard must always be set to the height of the PCB to be processed. Ensure that the gap be-
tween the guard and the safety bar is as small as possible. 2
Guards are fitted on the input and output belts of the PCB conveyor.
The height of the guard must be set using the slots so that the processed PCB can travel
through.
Fig. 2.5 - 3 Guard on the placement machine
(1) Safety bar (fixed)
(2) Guard (adjustable)
(3) Slots for adjusting the height
(4) Cover
2 Operational safety User Manual SIPLACE CS
2.5 Safety equipment Software Version SR.408.xx03/2006 US Edition
44
2.5.3 EMERGENCY STOP buttons, protective cover switches ...
Fig. 2.5 - 4 Location of the buttons and protective contactor combination K1
2
(1) Stop button
(2) Start button
(3) EMERGENCY STOP button
(4) EMERGENCY STOP button
(5) Start button
(6) Stop button
(7) Component counter
(8) Key switch open: position 0 for normal operation
Key switch shut: position I for service purposes
(9) Protective cover switch (output conveyor, 00303617-xx)
(10) Protective cover switch (right, 00321417-xx)
(11) Protective cover switch (input conveyor, 00303614-xx)
User Manual SIPLACE CS 2 Operational safety
Software Version SR.408.xx 03/2006 US Edition 2.5 Safety equipment
45
(12) Protective cover switch (left, 00321416-xx)
(13) Main power switch
(14) Protective contactor combination K1 at the power supply unit
(15) Compressed air unit
2.5.3.1 Description of the functions
EMERGENCY STOP button
When the EMERGENCY STOP button is pressed (item 3 or item 4. in Fig. 2.5 - 4), the motor
voltage to the gantry axes is switched off. The gantry axes are no longer powered, and thus are
not dangerous.
PLEASE NOTE
Placement is interrupted and can then either be continued or canceled once the system is working
correctly again. 2
Protective cover switch
If one of the protective covers is opened (see item 9, 10, 11 or 12 in Fig. 2.5 - 4), the gantry axes
will stop immediately. They are no longer powered, and thus are not dangerous.
Key-operated switch:
If the key switch (item 8 in Fig. 2.5 - 4) is closed (position I), the star can still be paced at low
speed while the protective covers are open. The gantry axes are no longer powered, and thus
are not dangerous.
PLEASE NOTE
The key switch remains open for normal mode, i.e. in the 0 position. 2
WARNING
The protective covers must only be opened, with the key switch closed (position I), by appropri-
ately qualified and trained personnel. 2
2.5.3.2 Status messages and the action required
The following displays may appear in placement mode. If they appear, carry out the action spec-
ified in the third column.