00194086-01 - 第83页

User Manual SIPLAC E CS 3 Technical data Software Vers ion SR.408.xx 03/2006 U S Edition 3.8 6-segment Collect&Place head 83 3.8.1.1 Descriptio n – The 6-se gment Collect& Place head works using th e "coll e…

100%1 / 160
3 Technical data User Manual SIPLACE CS
3.8 6-segment Collect&Place head Software Version SR.408.xx03/2006 US Edition
82
3
Fig. 3.8 - 2 Structure of the 6-segment Collect&Place head with standard component vision camera - part 2
3
(1) Forced air valve
(2) Turning station
(3) Vacuum generator
User Manual SIPLACE CS 3 Technical data
Software Version SR.408.xx 03/2006 US Edition 3.8 6-segment Collect&Place head
83
3.8.1.1 Description
The 6-segment Collect&Place head works using the "collect & place" principle, i.e. the compo-
nents are held by the nozzles with the aid of a vacuum and, after one complete pick-up cycle,
are placed gently and accurately on the PCB with the aid of forced air. The vacuum in the noz-
zles is also checked several times to determine whether the components were picked up and
set down correctly.
The "adaptive" sensor stop mode of the z axis compensates for any irregularity of the PCB sur-
face when the components are set down.
All the components are inserted with the same cycle time. Before the component is inserted, it
is measured by the optoelectronic vision module.
The component vision camera creates an image of the current component.
The precise position of the component is also determined.
The package form of the current component is compared against the programmed package
form in order to identify it. Any components that cannot be identified are rejected.
The turning station turns the component to the required placement position.
Defective components are rejected and are picked up again during a repair run.
3.8.1.2 Technical data
3
Component range 0201 to PLCC44, including BGA, µBGA, flip-chip,
TSOP, QFP, PLCC, SO to SO32, DRAM
Component specification
max. height
min. lead pitch
min. bump pitch
min. ball/bump diameter
min. dimensions
max. dimensions
max. weight
6 mm (10.7 mm available upon request)
0.5 mm
0.35 mm
0.2 mm
0.6 mm x 0.3 mm
18.7 mm x 18.7 mm
2 g
Programmable set-down force 2.4 to 5.0 N
Max. placement rate 10,000 comp/h
Nozzle types 9 xx
Angular accuracy ± 0.5° / 3 σ ± 0.7° / 4 σ
Placement accuracy ± 68µm / 3 σ ± 90µm / 4 σ
3 Technical data User Manual SIPLACE CS
3.9 Vision modules Software Version SR.408.xx03/2006 US Edition
84
3.9 Vision modules
3.9.1 Description
Each placement system has
two component vision cameras on the placement heads and
two PCB vision cameras on the underside of the X-axis gantries.
The vision analysis unit is located in the control unit for the placement system. The component
vision module is used to determine:
the precise position of the components at the nozzle and
the geometry of the package form.
The PCB vision camera uses fiducials on the PCBs to determine:
the position of the PCB,
its rotation angle
and the PCB skew.
The PCB vision camera also uses fiducials on the feeders to determine the exact pick-up posi-
tion of components. This is particularly important for small components.