SI-F130 Manual(EN)_jpg_ Rev1 - 第105页
Adjustment of H Axis Upper End OT Sensor (H-CCW) HLF-10404-01 Adjustment of H Axis Upper End OT Sensor (H-CCW) SHEET 1/3 Adjustment of H Axis Upper End OT Sensor (H-CCW) [Necessary jigs] • H axis sensor adjusting jig (L=…

H Axis Gear Z-phase Matching
HLF-10403-01
H Axis Gear Z-phase Matching
SHEET
4/4
11 Check that the clearance between the H axis pusher and inner shaft is 1.0 mm by thickness gauge.
Unless the clearance is 1.0 mm, it is necessary to re-perform “H axis origin position setup”.
12 Install the H axis lower end sensor (H-CW).
Perform position adjustment of the lower end sensor (H-CW) in the post-process of “Adjustment
H axis lower end OT sensor (H-CW)”.
13 Return the servo parameter of the H axis to the previous value.
Return the H axis parameter changed in the procedure 5 to the previous value and click the Set button.

Adjustment of H Axis Upper End OT Sensor (H-CCW)
HLF-10404-01
Adjustment of H Axis Upper End OT
Sensor (H-CCW)
SHEET
1/3
Adjustment of H Axis Upper End OT Sensor (H-CCW)
[Necessary jigs]
• H axis sensor adjusting jig
(L=15.5 mm, 15.0 mm)
• Thickness gauge (t=1.6 mm)
[Procedure]
1 Install the H axis sensor adjusting jig to the
inner shafts of turrets No.2 and No.12.
1. Push down the inner shaft of the tur-
ret No.2 and pinch the H axis sensor
adjusting jig (L=15.5 mm) between the
turret and inner shaft.
2. Push down the inner shaft of the tur-
ret No.12 and pinch the H axis sensor
adjusting jig (L=15.5 mm) between the
turret and inner shaft.
3. Remove the cap screw for H axis sen-
sor adjusting jig.
2 Turn off the servo for H axis.
1. Click in an order of M/C SETUP menu
ÎORG OFFSET tabÎR.H button.
RN/H Axis screen is displayed.
2. Click the servo OFF button for H axis.
Servo for H axis is turned off.
H axis sensor adjusting jig
15.5 mm
15 mm
H axis sensor
adjusting jig
Cap screw
Thickness gauge

Adjustment of H Axis Upper End OT Sensor (H-CCW)
HLF-10404-01
Adjustment of H Axis Upper End OT
Sensor (H-CCW)
SHEET
2/3
3 Loosen the cap screws (2-M3) on sensor
bracket for the H axis upper end OT sensor
to move the bracket downward (to lower
end).
The H axis upper end OT sensor is obstructed by the
dog, and the LED lights off.
Keep the cap screws (2-M3) in temporarily
tightened state.
4 Push down the H axis pusher by hand, place
a thickness gauge of 1.6 mm on the inner
shaft (No.1), and pinch with the H axis
pusher.
When pinching the thickness gauge,
slightly bring up the inner shaft from the
lower.
5 Move the sensor bracket for the H axis up-
per end OT sensor upward little by little,
tighten the cap screws (2-M3) at a position
of boundary where the lighting LED extin-
guishes, and secure the sensor bracket.
6 Remove the thickness gauge.
When the thickness gauge is removed, the LED for the H axis upper end OT sensor lights up.
7 Remove the H axis sensor adjusting jig installed on the turrets No.2 and No.12.
8 Perform origin position return of the H axis.
1. Click the ON button for the H axis
servo on the RN/H Axis screen.
The H axis servo is turned on.
2. Press the ORG button on the operation
panel with the RN/H Axis screen being
displayed.
The H axis returns to the origin.
3. Click the Return button to close the
RN/H Axis screen.
Sensor bracket
Cap screw
H axis upper end OT sensor
Thickness gauge
H axis pusher
Inner shaft