SI-F130 Manual(EN)_jpg_ Rev1 - 第137页

Nozzle Omission Detection Sensor P osition Adjustment HLF-10417-01 Nozzle Omission Detection Sensor Position Adjus tment SHEET 2/4 4 Set the nozzle omission detection sensor amplifier mounted on the side of the head. 1. …

100%1 / 310
Nozzle Omission Detection Sensor Position Adjustment
HLF-10417-01
Nozzle Omission Detection Sensor
Position Adjustment
SHEET
1/4
Nozzle Omission Detection Sensor Position Adjustment
[Necessary jigs]
Nozzle jig (AF06040)
Thickness gauge (t=1.0 mm)
[Procedure]
1 Install the nozzle jig (AF06040) to the turret
No.1.
2 Adjust the clearance between the nozzle
omission detection sensor and the upper
face of the nozzle reflector to 1.0 mm.
1. Loosen the cap screw for the nozzle
omission detection sensor.
2. Adjust with thickness gauge so that
clearance between the end of the noz-
zle omission detection sensor and the
upper face of the reflector is 1.0 mm.
3. Tighten the cap screw.
Fiber sensor is used in the nozzle omission
detection sensor.
3 Adjust the optical axis of the nozzle omission
detection sensor.
1. Loosen the split fastening screw fixing
the nozzle omission detection sensor.
2. Turn the nozzle omission detection
sensor to adjust so that the sensor lu-
minescence part is directed to reflector
plane of the nozzle jig (AF06040).
Optical axis can be easily adjusted by
slightly widening the split fastening part
of the bracket using flat end screwdriver.
3. Tighten the split fastening screw.
Nozzle jig (AF06040)
Thickness gauge
Cap screw
Nozzle omission
detection sensor
1.0 mm
Nozzle jig
(AF06040)
Reflector plane part
Split fastening screw
Sensor luminescence part
Nozzle Omission Detection Sensor Position Adjustment
HLF-10417-01
Nozzle Omission Detection Sensor
Position Adjustment
SHEET
2/4
4 Set the nozzle omission detection sensor
amplifier mounted on the side of the head.
1. Turn the SET/RUN selector switch to
the “SET” side.
“Teaching” window appears, and present light
receiving value/threshold value are displayed.
2. On “Teaching” display, press the
MODE button to change the display
without doing anything.
Changes to the “1. Detecting function”.
3. Set the “1. Detecting function” to the
“Std (standard setting)” and press the
MODE button.
Changes to the “2. Timer function”.
To change the selecting items on each set
display, press the UP / DOWN button.
4. Set the “2. Timer function” to “------
(timer ineffective)” and press the
MODE button.
Changes to the “3. Display change” display.
5. On the “3. Display change”, press the
MODE button without doing anything.
Changes to the “4. MODE setting”.
6. Set the “4. MODE setting” to “(Power
tuning execution)” and press the
MODE button.
Changes to the “5. Power tuning target value”
display.
ON/OFF dis
p
la
y
p
art
MODE
button
SET/RUN selector switch
Operation mode
se
l
ecto
r
s
wi
tc
h
MODE button
MODE button
MODE button
MODE button
MODE button
UP/DOWN button
Nozzle Omission Detection Sensor Position Adjustment
HLF-10417-01
Nozzle Omission Detection Sensor
Position Adjustment
SHEET
3/4
7. Set the “5. Power tuning target value”
to “2000” and press the MODE button.
Changes to the “6. Display direction”.
8. Set the “6. Display direction” to “D123
(normal setting)”.
5 Set sensitivity of the nozzle omission detec-
tion sensor.
1. Turn the SET/RUN selector switch to
the “RUN” side.
2. Press the MODE button for longer
than 3 seconds.
Light receiving value/threshold is automatically
adjusted.
L
SET RUN
UP DOWN MODE
D
3. Check the light receiving value.
If the light receiving value is within a range of
“2000±100”, setting is completed.
If the light receiving value is out of a range of
“2000±100”, re-perform the positional adjust-
ment of the nozzle omission detection sensor per-
formed in the procedures 2 and 3.
6 Set the threshold.
1. Click in an order of MANUAL menuÎ
AXIS MOTION tabÎR.H button.
RN/H Axis screen is displayed.
MODE button
SET/RUN selector switch
MODE button
Light receiving value
Threshold