Pickup Position Setup HLF-10314-01 Pickup Position Setup SHEET 1/7 Pickup Position Setup Pickup position setup can be performed at three locations on the front cassette table (Z1 06, Z120, Z139) and at three locations on…

100%1 / 310
Fixed Camera Calibration
HLF-10313-01
Fixed Camera Calibration
SHEET
7/7
17 After checking the recognition result, click
the Save button.
The fixed camera calibration result is saved, and the
Fixed Camera Calibration screen closes.
In order to store the calibration result in
the unit, be sure to re-start the unit before
operating the unit.
Pickup Position Setup
HLF-10314-01
Pickup Position Setup
SHEET
1/7
Pickup Position Setup
Pickup position setup can be performed at three locations on the front cassette table (Z106, Z120,
Z139) and at three locations on the rear cassette table (Z202, Z220, Z235).
Acquire XY position and H position by using jig at the respective position to setup pickup position.
[Necessary jigs]
Pickup point jig
Length reference nozzle jig
Thickness gauge (t=0.03 mm)
[Procedure]
1 Set the jig.
1. Install the length reference nozzle jig
to the turret No.1.
When installing the nozzle, insert it while
slowly turning.
After inserting the nozzle, check that it is
not drawn out by pulling downward.
2. Set pickup point jig to Z106 on the
cassette table.
Pickup point jig
Length reference
nozzle jig
Thickness gauge
Pickup point jig
Length reference
nozzle jig
Pickup Position Setup
HLF-10314-01
Pickup Position Setup
SHEET
2/7
2 Press the ORG button on the operation panel to perform origin position return.
3 Open the Cassette Pos. Data.
1. Click in an order of M/C SETUP menu
ÎPARTS SUPPLY tab.
Cassette position coordinates are displayed on
left part of the PARTS SUPPLY screen.
Cassette position coordinates