00197454-01_AI_Portal_40mm_TwinVHF_SX12_de_en - 第73页
Introduction 1.1.1 Conventions for the use of safety instructions Safety Instructions Reconfiguration Kit Twin VHF with Gantry Re configuration Kit Twin VHF mit Portal 73 1 1 I n t r o d u c t io n Introduction This guid…
Anhang
Auszüge aus der Serviceanleitung 4.1.3 Kopfadapter HCU und HCU tauschen
72 Reconfiguration Kit Twin VHF with Gantry Reconfiguration Kit Twin VHF mit Por
-

Introduction
1.1.1 Conventions for the use of safety instructions Safety Instructions
Reconfiguration Kit Twin VHF with Gantry Reconfiguration Kit Twin VHF mit Portal 73
1
1 Introduction
Introduction
This guide describes the installation of the "Reconfiguration Kit Twin VHF with Gantry" for 40 mm com
-
ponents on SIPLACE® SX1/SX2 V2 machines.
1.1
1.1 Safety Instructions
Safety Instructions
1.1.1
1.1.1 Conventions for the use of safety instructions
Conventions for the use of safety instructions
This manual contains notes that must be observed to guarantee your personal safety and to avoid dam
-
age to equipment. These notes are highlighted by warning triangles and are indicated as follows accord
-
ing to the level of risk:
DANGER
Nonobservance of these safety instructions may cause injury to personnel and damage to the
machine!
► Please observe the safety instructions in the user manual of the relevant machine for all
work!
DANGER
Definition
For the purposes of this manual, this indicates that fatal or severe injuries or considerable dam
-
age to property will occur if this hazard warning is not observed.
WARNING
Definition
For the purposes of this manual, this indicates that fatal or severe injuries or considerable dam
-
age to equipment may occur if these warning instructions are not followed.
CAUTION
Definition
For the purposes of this manual, this indicates that minor injuries or damage to property may
occur if this caution is not observed.
NOTICE
Definition
For the purposes of this manual, this note provides information about the product or indicates
a part of the manual that requires particular attention.

Introduction
Safety Instructions 1.1.2 Safety Instructions for Working with Strong Magnetic Fields
74 Reconfiguration Kit Twin VHF with Gantry Reconfiguration Kit Twin VHF mit Por
-
1.1.2
1.1.2 Safety Instructions for Working with Strong Magnetic Fields
Safety Instructions for Working with Strong Magnetic Fields
1.1.3
1.1.3 Safety Instructions for the Power Supply
Safety Instructions for the Power Supply
▪ This means that some parts of the system carry potentially lethal voltages - even when switched off
at the main power switch.
▪ Incorrect handling of the placement system can therefore result in fatal injuries, severe injuries or
considerable damage to equipment.
▪ Measurements and maintenance work must always be carried out by appropriately qualified person
-
nel.
▪ Always follow the applicable accident prevention and DIN regulations (particularly DIN EN 60 204,
part 1) or the regulations specific to your country.
▪ Before starting any maintenance work, switch the machine off at the main switch and disconnect it
from the main power supply.
▪ Always secure the machine against unauthorized reactivation. If these instructions are not followed,
you may be able to touch live parts, which could result in fatal or severe injuries.
Maintaining, Installing or Removing Assemblies
► End all placement operations on the machine.
► Shut down the Windows operating system correctly, otherwise problems may occur when restarting
or data may be lost.
► Switch the machine off at the main switch.
► Disconnect the machine from the main power supply.
► Switch off the machine and attach warnings signs to indicate that service work is in progress.
DANGER
Strong permanent magnet fields
Fatal hazard: persons with active implants (e.g. pacemakers, defibrillators, insulin pumps etc.)
are at risk from strong permanent magnetic fields inside the machine.
Persons at risk should avoid the immediate vicinity of the machine.
CAUTION
Danger of crushing
Danger of crushing for persons with passive metal implants (e.g. plates, screws).
► Do not reach or lean over into the machine when the protective covers are open.
► Do not bring any metal objects into the hazard area.
CAUTION
Strong permanent magnet fields
There is a risk that the strong magnetic fields could corrupt data on data media or check cards.
► Keep sensitive data supports away from the permanent magnets.
WARNING
Hazardous Voltages!
The machine is supplied with 3 x 400 V~ (or. 3 x 204 V~ / 3 x 220 V~ / 3 x 230 V~ / 3 x 380 V~
/ 3 x 415 V~) ± 5 %, 50/60 Hz mains voltages.
► Observe the safety instructions in the user manual during all service work!