00197454-01_AI_Portal_40mm_TwinVHF_SX12_de_en - 第93页
Brief Description 2.1.6 Configurations Overview Reconfiguration Kit Twin VHF with Gantry Re configuration Kit Twin VHF mit Portal 93 2.1.6.2 2 . 1 . 6 . 2 S t a t io n a r y C a m e r a s Stationary Cameras Stationary ca…

Brief Description
Overview 2.1.6 Configurations
92 Reconfiguration Kit Twin VHF with Gantry Reconfiguration Kit Twin VHF mit Por
-
2.1.6
2.1.6 Configurations
Configurations
2.1.6.1
2.1.6.1 Table Positions
Table Positions
The table position required for the SIPLACE SX1/SX2 varies according to the head configuration:
SIPLACE SX1:
SIPLACE SX2:
Gantry 1 C&P20A CPP_L CPP_H without
stat. camera
CPP_H with
stat. camera
TH/TwinVHF
Table position
location 1
Inner Inner Inner Outer Outer
Table position
location 2
Inner Inner Inner Inner Inner
Gantry 1 C&P20A CPP_L CPP_H
with stat.
camera
CPP_H
with stat.
camera
TH/ Twin
-
VHF
TH/ Twin
-
VHF
TH/ Twin
-
VHF
Table position
location 1
Inner Inner Outer Outer Outer Outer Outer
Gantry 2 C&P20A CPP_L CPP_H
with stat.
camera
CPP_H
without
stat. cam
-
era
CPP_H
with stat.
camera
CPP_H
without
stat. cam
-
era
TH/ Twin
-
VHF
Table position
location 2
Inner Inner Outer Inner Outer Inner Outer
NOTICE
Stationary cameras
CPP: only with stationary camera IC camera SST33
TH/Twin VHF: with stationary camera IC camera SST33 at both locations, FC camera SST25
at location 1 only

Brief Description
2.1.6 Configurations Overview
Reconfiguration Kit Twin VHF with Gantry Reconfiguration Kit Twin VHF mit Portal 93
2.1.6.2
2.1.6.2 Stationary Cameras
Stationary Cameras
Stationary cameras on the SX1
SX1
1. Location 1 in outer position
2. Location 2 in inner position
3. Gantry 1
4. IC camera and/or FC camera/3D coplanarity module
(location 1)
You can only install either an FC camera or a 3D co
-
planarity module!
Stationary cameras on the SX2
SX2
1. Location 1 in outer position
2. Location 2 in outer position
3. Gantry 1
4. Gantry 2
5. IC camera and/or FC camera/3D coplanarity module
(location 1)
You can only install either an FC camera or a 3D co
-
planarity module!
6. IC camera (location 2)

Brief Description
Prerequisites 2.2.1 SIPLACE SX "Prepared"
94 Reconfiguration Kit Twin VHF with Gantry Reconfiguration Kit Twin VHF mit Por
-
2.2
2.2 Prerequisites
Prerequisites
▪ This option is possible for SX1, SX1prepared and SX2 machines.
▪ Serial number from Mxxx (higher input and output area)
Serial number from Lxxx restricted (max. 35 mm component height)
▪ Station software 707.0x
▪ SIPLACE Pro 11.1
▪ WPC5/6 - 45 mm (serial numbers from B3xxx/C3xxx)
This WPC is needed for feeding in components with heights up to 40 mm.
▪ A combination with the "Smart Pin Support" option is also possible. In this case, you need the appro
-
priately adapted pin picker.
2.2.1
2.2.1 SIPLACE SX "Prepared"
SIPLACE SX "Prepared"
The SIPLACE SX must be in the delivery state "Pre
-
pared".
This can be recognized by the presence of a trailing cable
(1) and the control unit for the main axes (Gantry Control
Unit (2)). This applies for the SIPLACE SX+ machine, in
order to retrofit gantry 1 at location 1 or for the SIPLACE
SX1 "Prepared", in order to retrofit gantry 2 at location 2.
The trailing cable is packed in a black plastic case and is
fixed at the side (1).
If this is not the case, your machine will need to be retro
-
fitted accordingly. Contact your SIPLACE Service team
for details.