EUKYX 1-70 199-4100 5.7 Nozzle Filter Insertion Procedure 5. 7 Nozzle Fi lt er Inser tion Procedure • Fil ter replacement j ig There ar e 2 filter replacement j igs : for High- Spee d No z zle and for Nozzle picki ng up M…

100%1 / 363
EUKYX
1-69199-4100
5.6 Hydraulic Cleaning Machine
For using the nozzle tip cleaning jig
A jig for cleaning HG24C or HG33C from the tip with a pin gauge, is provided.
Pin Gauge
Nozzle
Nozzle Tip Cleaning Jig
F4A54
Insert the nozzle from the tip section into the jig and insert the pin gauge gently into the nozzle tip
hole with the nozzle pressed against the jig.
In the case that the pin gauge is not easily inserted, do not insert it forcibly, but repeat the pin
gauge moving up and down.
5.6 Hydraulic Cleaning Machine
A commercially available hydraulic cleaning machine can be used.
Example : MAC3 III (Maker : Nakamura Cyoukou)
When the hole is clogged with solder paste, the cleaning might not be available.
Clean it also with the pin gauge. After the cleaning, dry it completely with air-blow or dryer.
Note
EUKYX
1-70199-4100
5.7 Nozzle Filter Insertion Procedure
5.7 Nozzle Filter Insertion Procedure
Filter replacement jig
There are 2 filter replacement jigs: for High-Speed Nozzle and for Nozzle picking up Middle-
Size/Odd-Shape component. The same procedures apply to both jigs.
For Nozzle picking up
Middle-Size/Odd-Shape
component
For High-Speed Nozzle
Nozzle set position
F4A83
(1) Set the nozzle filter in the nozzle filter set position with tweezers or similar tool.
Nozzle filter set position
F4A58A
(2) Set the acrylic block on the nozzle filter set position.
Acrylic block
(for holing filter)
Acrylic block set on nozzle filter set position
Nozzle filter set position
F4A59A
Note
Procedure
EUKYX
1-71199-4100
5.7 Nozzle Filter Insertion Procedure
(3) Insert the nozzle into the nozzle set position. At this time, face the nozzle clearance for
nozzle filter must face toward the acrylic block (in the direction of white arrow).
Make sure to face the nozzle clearance in the correct direction.
Nozzle clearance for nozzle filter
must face in this direction.
Nozzle
F4A60A
(4) Press the acrylic block and move the slider in the direction of white arrow to insert the
nozzle filter into the nozzle clearance.
Slider
Acrylic block
F4A62A
(5) Press the lever to detach the nozzle. At this time, a click is heard.
Acrylic block
Press the lever.
F4A82
Note