EUKYX-199-4110_G5S2_Instruction_Vol4_E - 第145页
EUKYX 2-16 199-4100 2.2 Management Information list Code D isp lay Ar ea A Di spl ay Are a B 5 0 51 3 Conver t Width Setup The s et valu e of W 1 a xis exce ed s the sof t li mit. Ple ase d eterm ine th e valu e with in …

EUKYX
2-15199-4100
2.2 Management Information list
Code Display Area A Display Area B
50404 Manual transfer
PCB (X > 260 mm) which is set by PP data is unable to be taken in
Input Conveyor.
50405 Manual transfer
There is PCB on Deceleration Sensor of Input Conveyor. There is a
possibility that PCB is inserted.
50406 Manual transfer
There is PCB on Deceleration Sensor of Shuttle Conveyor in Output
side. There is a possibility that PCB is inserted.
50407 Manual transfer
Lane A is not able to be set in Current Program. Please change
Current Program or change to Lane B.
50408 Manual transfer
Lane B is not able to be set in Current Program. Please change
Current Program or change to Lane A.
50409 Manual transfer
PCB Y size and Conveyor Width in Current Program are not equal.
Please change Current Program.
5040a Manual transfer Cutout PCB cannot be taken in input position.
5040b Manual transfer
Please remove PCB from input position. Cutout PCB cannot be
transferred from input position.
5040c Manual transfer It is not possible to transport it to the specified position.
5040d Manual transfer
It is not possible to operate because it interferes in the adsorption
treatment device.
5040e Manual transfer It composes the device, and it is not possible to operate.
5040f Manual transfer
PCB (X > 280 mm) which is set by PP data is unable to be taken in
Input Position.
50410 Manual transfer Output a PCB after interrupting operation.
50 411 Manual transfer
It is not possible to operate, because there is a PCB in the upstream
position. Please take a PCB from upstream position.
50412 Manual transfer
It is not possible to operate, because there is a P.C.B. in the input
conveyor. Please take a P.C.B. in the input conveyor.
50501 Convert Width Setup
Please set conveyor width 49.5 ~ 461.5 mm. The total of PCB size/
offset/clearance is over movable range.
50502 Convert Width Setup
Please set conveyor width 49.5 ~ 382.5 mm. The total of PCB size/
offset/clearance is over movable range.
50503 Convert Width Setup
Movable Range for the destination of W1 is set. Please check PCB
size/offset/clearance of Lane A.
50504 Convert Width Setup
Movable Range for the destination of W1 is set. Please check PCB
size/offset/clearance of Lane A.
50505 Convert Width Setup
Movable Range for the destination of W2 is set. Please check PCB
size/offset/clearance of Lane A
50506 Convert Width Setup
Movable Range for the destination of W2 is set. Please check PCB
size/offset/clearance of Lane A.
50507 Convert Width Setup
Movable Range for the destination of W3 is set. Please check PCB
size/offset/clearance of Lane B.
50508 Convert Width Setup
Movable Range for the destination of W3 is set. Please check PCB
size/offset/clearance of Lane B.
50509 Convert Width Setup
These is a possibility of the interference with W1 and W2. Please
check PCB size/offset/clearance of Lane A.
5050a Convert Width Setup
There is a possibility of the interference with W2 and W3. Please
Check PCB size/offset/clearance of Lane A/B.
5050b Convert Width Setup
There is an interference between object position of Conveyor and
Support Pin. Please exchange Support Pin.
50510 Convert Width Setup Zeroing of W1 axis is not finished. Please perform zeroing of W1 axis.
50 511 Convert Width Setup Zeroing of W2 axis is not finished. Please perform zeroing of W2 axis.
50512 Convert Width Setup Zeroing of W3 axis is not finished. Please perform zeroing of W3 axis.

EUKYX
2-16199-4100
2.2 Management Information list
Code Display Area A Display Area B
50513 Convert Width Setup
The set value of W1 axis exceeds the soft limit. Please determine the
value within the range from 300.5 mm to 468.5 mm.
50514 Convert Width Setup
The set value of W1 axis exceeds the soft limit. Please determine the
value within the range from 368.5 mm to 536.5 mm.
50515 Convert Width Setup
The set value of W2 axis exceeds the soft limit. Please determine the
value within the range from 250.5 mm to 418.0 mm.
50516 Convert Width Setup
The set value of W2 axis exceeds the soft limit. Please determine the
value within the range from 284.5 mm to 452.0 mm.
50517 Convert Width Setup
The set value of W3 axis exceeds the soft limit. Please determine the
value within the range from 49.5 mm to 382.5 mm.
50518 Convert Width Setup
The set value of W3 axis exceeds the soft limit. Please determine the
value within the range from 83.5 mm to 416.5 mm.
50519 Convert Width Setup
There is an interference between W1 axis and W2 axis. Please change
the value or separate the interfering axis.
5051a Convert Width Setup
There is an interference between W2 axis and W3 axis. Please change
the value or separate the interfering axis.
5051b Convert Width Setup
Please set conveyor width 83.5~511.5 mm. The total of PCB size/
offset/clearance is over movable range.
5051c Convert Width Setup
Please set conveyor width 49.5~511.5 mm. The total of PCB size/
offset/clearance is over movable range.
50601 Convert Width Setup
Rotation Direction set of Middle Conveyor in supply side differs from
Main Device transfer direction. Please change the rotation direction of
Middle conveyor.
50602 Convert Width Setup
Emergency Stop switch of middle conveyor in supply side is pressed.
Please cancel it.
50603 Convert Width Setup
Safety Cover of middle conveyor in supply side is open. Please close
it.
50604 Convert Width Setup
Input Machine communication mode is set [PUSHER]. Cannot use
[PUSHER] mode when Middle Conveyor is contacted.
50 611 Convert Width Setup
Rotation Direction set of Middle Conveyor in output side differs from
Main Device transfer direction. Please change the rotation direction of
Middle conveyor.
50612 Convert Width Setup
Emergency Stop switch of middle conveyor in output side is pressed.
Please cancel it.
50613 Convert Width Setup
The Safety Cover of middle conveyor in output side is open. Please
close it.
050701 Convert Width Setup
Emergency Stop Switch of Shuttle Conveyor in Input side is pressed.
Please cancel it.
050702 Convert Width Setup
The safety cover of Shuttle Conveyor in Input side is open. Please
close it.
050703 Convert Width Setup
Deceleration sensor of Shuttle Conveyor in Input side is detected.
Please remove PCB because there is a possibility that it is inserted.
050704 Convert Width Setup
Deceleration Sensor of Input Conveyor is detected. Please remove
PCB because there is a possibility that it is inserted.
050705 Convert Width Setup
Deceleration Sensor of Input Conveyor in Lane A is detected. Please
remove PCB because there is a possibility that it is inserted.
050706 Convert Width Setup
Deceleration Sensor of Input Conveyor in Lane B is detected. Please
remove PCB because there is a possibility that it is inserted.
050707 Convert Width Setup
Set Value of Delivery Position of Device System/Input Machine PCB is
not in the Movable Range. Please set the value 467 mm and less
whose value is the sum with Y size of PCB.
050708 Convert Width Setup
Please set [SMEMA] Mode for Device System/Input Machine Output.
And, Please confirm that Inp/Outp Machine Signal is set as [Enable].
050709 Convert Width Setup
Please set the same value in Lane A / Lane B of Delivery Position of
Device System/Input Machine PCB.

EUKYX
2-17199-4100
2.2 Management Information list
Code Display Area A Display Area B
05 0711 Convert Width Setup
Emergency Stop Switch of Shuttle Conveyor in Output side is pressed.
Please cancel it.
050712 Convert Width Setup
The safety cover of Shuttle Conveyor in Output side is open. Please
close it.
050713 Convert Width Setup
Deceleration Sensor of Shuttle Conveyor in Output side is detected.
Please remove PCB there is a possibility that it is inserted.
050714 Convert Width Setup
Stop Sensor of Output Conveyor is detected. Please remove PCB there
is a possibility that it is inserted.
050715 Convert Width Setup
Stop Sensor of Output Conveyor in Lane A is detected. Please remove
PCB there is a possibility that it is inserted.
050716 Convert Width Setup
Stop Sensor of Output Conveyor in Lane B is detected. Please remove
PCB there is a possibility that it is inserted.
050717 Convert Width Setup
Set Value of Delivery Position of Device System/Output Machine PCB
is not in the Movable Range. Please set the value 467 mm and less
whose value is the sum with Y size of PCB.
050718 Convert Width Setup
Please set [SMEMA] Mode for Device System/Output Machine Output.
And, Please confirm that Inp/Outp Machine Signal is set as [Enable].
050801
Warning about
Maintenance
It is time to perform the feeder maintenance.
60101
Feeder communication
Error
Can not communicate with Feeder. Please confirm that selected
Feeder is put in.
60201 Feeder type Error Library and Feeder are inconsistent.
60301
Feeder preparation
Error
Please drop Feeder base once. Then, rise it again.
60401 Feeder No. Error Cannot Pick-up The Feeder. Please select another one.
60501 Nozzle Check Nozzle is placed. Please Store it, and then retry to execute.
60601 Cart Check
Safety cover was not locked by following reasons. 1. Feeder Cart
position [S151F,S151B] 2. Safety circuit (Safety Relay [K3,K4], Safe
cover lock [S131,S132], Emergency stop [S105F,S105B], Magnetic
contractor [K33A,K33B], Relay [K11], Cable condition)
60602 Cart Check Cart (Block1) is not at upper position. Please put it up.
60603 Cart Check Cart (Block2) is not at upper position. Please put it up.
60604 Cart Check
Cannot operate it because Cart (Block1) is not at upper position or its
connector is off.
( It is dangerous to put the hand into a space between the Cart and the
Safety Cover.)
60605 Cart Check
Cannot operate it because Cart (Block2) is not at upper position or its
connector is off.
(It is dangerous to put the hand into a space between the Cart and the
Safety Cover.)
60606 Cart Check Please operate it after shutting the feeder area cover (Blocks 1 and 2).
60701
Error in Carrier
supplying Cmpnt
It is impossible to pick-up this cmpnt from specified Feeder. Please
change the Placement mode as [By Hand].
60702
Error in Carrier
supplying Cmpnt
Feeder location in equipment is not in agreement with a current pattern
program.
Please check feeder location in a FEEDER LOCATION screen.
60801 Cutter Please close and lock the safety cover, and then operate it (Block1).
60802 Cutter Please close and lock the safety cover, and then operate it (Block2).