EUKYX-199-4110_G5S2_Instruction_Vol4_E - 第183页

EUKYX 3-19 199-4100 3.1 Safety Device Error ID Error Name, Description, Cause, and Remedy 4 0 6 9 01 Dete ct ing pi cku p mis s cmp nt on T ray Pal let ( Blo ck1) Pic k -up m iss c mpn t is dete ct ed on T r ay palle t (…

100%1 / 363
EUKYX
3-18199-4100
3.1 Safety Device
Error ID Error Name, Description, Cause, and Remedy
405001 Detecting pickup miss cmpnt on Tray Pallet (Block2)
Pickup miss components on the Pallet is detected.(Block2) [B15419]
Open the main cover and remove pickup miss components on the Tray Pallet.
405101 Detecting lower Magazine rack shutter (Block2)
the rack shutter opening is detected during lower elevator moving.(Block2)
[B15521, B15523,B15525]
Check out the sensor of closing magazine rack shutter (B15521, B15523, B15525).
405201 Detecting upper Magazine rack shutter (Block2)
the rack shutter opening is detected during upper elevator moving.(Block2)[B15527,
B15529,B15531]
Check out the sensor of closing magazine rack shutter (B15527, B15529, B15531).
405301 Lower magazine positioning error (Block2)
Lower magazine positioning error.(Block2)[B15526]
Confirm Magazine Clamp.
405401 Upper magazine positioning error (Block2)
Upper magazine positioning error.(Block2)[B15532]
Confirm Magazine Clamp.
405501 Shut-off Motor Breaker for Tray (Block2)
Tripped circuit breaker of motor (Block2)
Please turn on again after turning off and cancelling Trip mode.
405601 Shut-off safety relay of Elevator(Lower) (Block2)
Cut off safety relay of lower elevator (Block2).
Confirm the main circuit and safety door.
405701 Shut-off safety relay of Elevator(Upper) (Block2)
Cut off safety relay of upper elevator (Block2).
Confirm the main circuit and safety door.
405801 Released Elevator unit clamp(Block2)
Released elevator unit clamp(Block2)[B15426, B15428]
Confirm the Elevator Unit Clamp Sensor(B15426, B15428).
405901 Detecting pickup miss cmpnt of Tray Feeder Cart (Block2)
Pickup miss components was detected(Block2). [B15412]
1.Open the cover.
2.Confirm suppressor, Disengaged Latch and remove the Pickup miss cmpnt.
3.Close the cover and then lock it.
405A01 Detecting Feeder Disengaged Latch of Tray Feeder Cart(Block2)
Feeder Disengaged Latch is detected (Block2).[B15412]
1.Open the cover.
2.Confirm suppressor, Disengaged Latch and remove the Pickup miss cmpnt.
3.Close the cover and then lock it.
406701 Detecting pickup miss cmpnt on Tray Pallet (Block1)
Pick-up miss cmpnt is detected on Tray pallet (Block1)
Please open the main cover, and remove the pick-up miss cmpnt on Tray pallet.
406801 Detecting pickup miss cmpnt on Tray Pallet (Block1)
Pick-up miss cmpnt is detected on Tray pallet (Block1)
Please open the main cover, and remove the pick-up miss cmpnt on Tray pallet.
EUKYX
3-19199-4100
3.1 Safety Device
Error ID Error Name, Description, Cause, and Remedy
406901 Detecting pickup miss cmpnt on Tray Pallet (Block1)
Pick-up miss cmpnt is detected on Tray pallet (Block1)
Please open the main cover, and remove the pick-up miss cmpnt on Tray pallet.
406A01 Detecting pickup miss cmpnt on Tray Pallet (Block1)
Pick-up miss cmpnt is detected on Tray pallet (Block1)
Please open the main cover, and remove the pick-up miss cmpnt on Tray pallet.
406B01 Detecting pickup miss cmpnt on Tray Pallet (Block2)
Pick-up miss cmpnt is detected on Tray pallet (Block2)
Please open the main cover, and remove the pick-up miss cmpnt on Tray pallet.
406C01 Detecting pickup miss cmpnt on Tray Pallet (Block2)
Pick-up miss cmpnt is detected on Tray pallet (Block2)
Please open the main cover, and remove the pick-up miss cmpnt on Tray pallet.
406D01 Detecting pickup miss cmpnt on Tray Pallet (Block2)
Pick-up miss cmpnt is detected on Tray pallet (Block2)
Please open the main cover, and remove the pick-up miss cmpnt on Tray pallet.
406E01 Detecting pickup miss cmpnt on Tray Pallet (Block2)
Pick-up miss cmpnt is detected on Tray pallet (Block2)
Please open the main cover, and remove the pick-up miss cmpnt on Tray pallet.
407001 Detecting Head1 nozzle descending
Invalid detection of head1 nozzle descending
Please perform a zeroing.
407101 Detecting Head2 nozzle descending
Invalid detection of head2 nozzle descending
Please perform a zeroing.
407201 Pass Line detect(Head1)
Invalid detection of Pass line(Head1)
Please perform a zeroing.
407301 Pass Line detect(Head2)
Invalid detection of Pass line(Head2)
Please perform a zeroing.
408001 Nozzle interference detect adjacent to multi-functional head
Emergency stopped a head because a nozzle adjacent to it interfered.
Please perform a zeroing.
408301 Feeder opening sensor (Block 1) detect
The feeder opening sensor (Block 1) was shaded.
Please remove the factor which is shading the feeder opening sensor (Block1), and restart.
408401 Feeder opening sensor (Block 2) detect
The feeder opening sensor (Block 2) was shaded.
Please remove the factor which is shading the feeder opening sensor (Block2), and restart.
EUKYX
3-20199-4100
3.2 Data
3.2 Data
Error ID Error Name, Description, Cause, and Remedy
410301 Pattern Program Error
Steps in converted pattern program is more
-----
410302 Pattern Program Error
There are Errors in converted pattern program(PCB recog steps Error.)
-----
410303 Pattern Program Error
The converted pattern program is not exist, the data is damaged.
-----
410304 Pattern Program Error
The error is found in the adsorption nozzle number of the conversion pattern program.
-----
410305 Pattern Program Error
The error is found in the order of adsorption of the conversion system pattern program.
-----
410306 Pattern Program Error
The error is found in the nozzle candidate number of the conversion pattern program.
-----
410307 Pattern Program Error
The error is found in the adsorption lane number of the conversion pattern program.
-----
410401 Data Error
The components library does not exist. Or, data is in loss.
-----
410402 Data Error
Data relating to nozzle does not exist. Or, data is in loss.
-----
410701 Program Error
It was a error setting of the sequence data.
-----
410801 2D bar code data Error
It was a error setting of the sequence data.
-----
410802 2D bar code data Error
Failed in start-up Sequence
-----
410803 2D bar code data Error
The error is found in coordinates calculation.
-----
410804 2D bar code data Error
Could not continue for Errors.
-----