EUKYX-199-4110_G5S2_Instruction_Vol4_E - 第242页
EUKYX 3-77 199-4100 3.8 Automatic Adjustment 3.8 Aut omatic Adjustment Error ID Error Name, Description, Cause, and Remed y 49060 3 Conveyor Width Automatic Adjustment PCB exist s on th e L conveyo r . ----- 49060 4 Conv…

EUKYX
3-76199-4100
3.7 PEC Recognition
Error ID Error Name, Description, Cause, and Remedy
46010e P.E.C. Inspection
Failed in Land recog
Please perform methods to the following.
1. Check Mark on the PCB
2. Revise PCB positioning
46010f P.E.C. Inspection
P.E.C. Mark #1 (Unit)
----
46 0110 P.E.C. Inspection
P.E.C. Mark #2 (Unit)
----
46 0111 P.E.C. Inspection
P.E.C. Mark #3 (Unit)
----
460201 2D bar code Error
Failed in reading 2D bar code
Please perform to the following
1. The condition of PCB Positioning
2. Specify the position of 2D bar code
3. Detect the dirty of 2D bar code

EUKYX
3-77199-4100
3.8 Automatic Adjustment
3.8 Automatic Adjustment
Error ID Error Name, Description, Cause, and Remedy
490603 Conveyor Width Automatic Adjustment
PCB exists on the L conveyor.
-----
490604 Conveyor Width Automatic Adjustment
PCB exists on the R conveyor.
-----
49 0617 Conveyor Width Automatic Adjustment
Software limit
-----
490690 Conveyor Width Automatic Adjustment
Auto Setup Error(Others).
-----
490701 Nozzle set up
Nozzle Stocker is not set.
Please check whether it is correctly set to the stocker base.
490702 Nozzle set up
Motor Error Detection.
-----
490703 Nozzle set up
Nozzle Stocker Shutter open/close failed.
There is no float going up of a nozzle, or please check whether there is any connection etc.
in opening and closing.
490704 Nozzle set up
The up/down movement of Nozzle Stocker failed.
Please confirm whether Upper/Lower Cylinder has no error.
490705 Nozzle set up
Nozzle placing was not found in the stocker.
Check whether there is any difference in stocker arrangement data and real arrangement.
490707 Nozzle set up
There is no free space for nozzle storing. Please confirm the arrangement data.
Please confirm the Stocker arrangement data.
490708 Nozzle set up
There are neither a free space nor a nozzle for nozzle exchange.
Please set up an insufficient nozzle in Nozzle stocker.
490709 Nozzle set up
Nozzle exchange abnormal data was found.
Please confirm the nozzle arrangement and the Stocker arrangement data.
49070a Nozzle set up
Nozzle stocker position teaching failed.
Please teach the Nozzle stocker position again on the instruction screen.
49070c Nozzle set up
Nozzle level teach error Detection.
Please execute the nozzle level teaching again on the nozzle level teach screen, and
confirm there is no unexpected value.

EUKYX
3-78199-4100
3.8 Automatic Adjustment
Error ID Error Name, Description, Cause, and Remedy
49070d Nozzle set up
It failed in the nozzle placement check.
Confirm the recognition image and select the nozzle existence.
Please select a recognition image and choose the existence of a nozzle.
49070e Nozzle set up
The remains nozzle was detected on the head. The nozzle cannot be set to this position.
Please confirm the nozzle has not adhered to the position.
Moreover, please clean the side view camera when not adhering.
49070f Nozzle set up
Abnormal nozzle level detected. Possibilities are the nozzle was not fully inserted in the
head, or Side View Camera saw dust or scratch.
Please confirm whether the nozzle has adhered to the position.
490710 Nozzle set up
The receipt nozzle was undetectable on the head.
Please confirm whether the nozzle has adhered to the position.
49 0711 Nozzle set up
The remains nozzle was detected on the head.
Please confirm the nozzle has not adhered to the position.
Moreover, please clean the side view camera when not adhering.
490712 Nozzle set up
The side view camera error occurred in the head nozzle existence check.
Please confirm the nozzle arrangement, and execute the level teaching.
490713 Nozzle set up
The nozzle exchange sequence error occurred.
Please confirm the nozzle placement.
490716 Nozzle set up
Time-out of close nozzle stocker operation.
Nozzle stocker was opened for safety. Please confirm whether there is no rise to the surface
the nozzle is not in opening and shutting caught state.
490722 Nozzle set up
An error occurred with the nozzle existence check in the stocker before the nozzle is stored.
-----
490723 Nozzle set up
It failed in the nozzle storage check.
Confirm the recognition image and select the nozzle existence.
-----
490730 Nozzle set up
Error in calculating recognized position of Nozzle ID.(XY-axis)
-----
490731 Nozzle set up
Failed in starting XY-axis.
-----
490732 Nozzle set up
Time-out of XY-axis
-----