EUKYX-199-4110_G5S2_Instruction_Vol4_E - 第244页
EUKYX 3-79 199-4100 3.8 Automatic Adjustment Error ID Error Name, Description, Cause, and Remed y 49 07 33 N ozzle s et up Mot or Erro r of XY - ax is ----- 49 07 34 N ozzle s et up Erro r in Ligh t on of P .C.B. rec og …

EUKYX
3-78199-4100
3.8 Automatic Adjustment
Error ID Error Name, Description, Cause, and Remedy
49070d Nozzle set up
It failed in the nozzle placement check.
Confirm the recognition image and select the nozzle existence.
Please select a recognition image and choose the existence of a nozzle.
49070e Nozzle set up
The remains nozzle was detected on the head. The nozzle cannot be set to this position.
Please confirm the nozzle has not adhered to the position.
Moreover, please clean the side view camera when not adhering.
49070f Nozzle set up
Abnormal nozzle level detected. Possibilities are the nozzle was not fully inserted in the
head, or Side View Camera saw dust or scratch.
Please confirm whether the nozzle has adhered to the position.
490710 Nozzle set up
The receipt nozzle was undetectable on the head.
Please confirm whether the nozzle has adhered to the position.
49 0711 Nozzle set up
The remains nozzle was detected on the head.
Please confirm the nozzle has not adhered to the position.
Moreover, please clean the side view camera when not adhering.
490712 Nozzle set up
The side view camera error occurred in the head nozzle existence check.
Please confirm the nozzle arrangement, and execute the level teaching.
490713 Nozzle set up
The nozzle exchange sequence error occurred.
Please confirm the nozzle placement.
490716 Nozzle set up
Time-out of close nozzle stocker operation.
Nozzle stocker was opened for safety. Please confirm whether there is no rise to the surface
the nozzle is not in opening and shutting caught state.
490722 Nozzle set up
An error occurred with the nozzle existence check in the stocker before the nozzle is stored.
-----
490723 Nozzle set up
It failed in the nozzle storage check.
Confirm the recognition image and select the nozzle existence.
-----
490730 Nozzle set up
Error in calculating recognized position of Nozzle ID.(XY-axis)
-----
490731 Nozzle set up
Failed in starting XY-axis.
-----
490732 Nozzle set up
Time-out of XY-axis
-----

EUKYX
3-79199-4100
3.8 Automatic Adjustment
Error ID Error Name, Description, Cause, and Remedy
490733 Nozzle set up
Motor Error of XY-axis
-----
490734 Nozzle set up
Error in Light on of P.C.B. recognition camera.
-----
490735 Nozzle set up
Error in capturing a image of P.C.B. recognition camera.
-----
490736 Nozzle set up
Error in recognizing Nozzle ID
-----
490737 Nozzle set up
Error in Light Off of P.C.B. recognition camera.
-----
490738 Nozzle set up
Error in calculating Nozzle check position internal stocker.(XY-axis)
-----
490739 Nozzle set up
Error in recognizing Nozzle existence.
-----
49073A Nozzle set up
Can not recognize Nozzle ID
Please confirm the direction of Nozzle and the existence of Marking, the dirt inside Nozzle
stocker.
49073B Nozzle set up
Nozzle set in Nozzle Stocker and Nozzle data is not Identical.
Please confirm Nozzle and Nozzle data of the machine inside nozzle stocker.
49073C Nozzle set up
Error in nozzle exchange
-----
49073D Nozzle set up
Error in recognition sequence of Nozzle ID.
49073E Nozzle set up
Necessary Stocker Area for recognition Nozzle ID is skipped.
Clear the skip set of nozzle stocker.
49073F Nozzle set up
Time-out of Nozzle type data received.
-----
490740 Nozzle set up
Error of Nozzle type data received.
-----
490741 Nozzle set up
Error in updating Nozzle data.
-----

EUKYX
3-80199-4100
3.8 Automatic Adjustment
Error ID Error Name, Description, Cause, and Remedy
490742 Nozzle set up
Failed in start-up Z-axis
-----
490743 Nozzle set up
Time-out of start-up Head
-----
490744 Nozzle set up
Time-out of head
-----
490745 Nozzle set up
Error in calculating Noz exchanging position in L-axis
-----
490746 Nozzle set up
Failed in start-up L-axis
-----
490747 Nozzle set up
Time-out of start-up L-axis
-----
490748 Nozzle set up
Time-out of L-axis
-----
490749 Nozzle set up
Error in calculating Noz exchanging position in XY-axis
-----
49074A Nozzle set up
Error in calculating Noz exchanging position in L-axis.
-----
49074B Nozzle set up
Failed in getting arrangement data of Nozzle Stocker
-----
49074C Nozzle set up
Nozzle is found in Stocker, but Disagreement ID or ID recog failed.
Please confirm the type and direction of Noz inside Stocker.
Check the existence of the dirt or flaw if there is no problem.
49074D Nozzle set up
Error in coordinate calculation of Noz Stocker Mark position.
-----
49074E Nozzle set up
Error in coordinate calculation of detect starting position for Side View Camera.
-----
49074F Nozzle set up
Error in coordinate calculation of detect finishing position for Side View Camera
-----
490750 Nozzle set up
Error in coordinate calculation of recog position of Noz ID
-----