EUKYX-199-4110_G5S2_Instruction_Vol4_E - 第250页

EUKYX 3-85 199-4100 3.8 Automatic Adjustment Error ID Error Name, Description, Cause, and Remed y 49 078 D Noz zle s et up Exc hang ing Noz h as not f inis hed w ithin p red eter mine d time ----- 49 078 E Noz zle set u …

100%1 / 363
EUKYX
3-84199-4100
3.8 Automatic Adjustment
Error ID Error Name, Description, Cause, and Remedy
49077E Nozzle set up
Error in recognizing Noz Stocker Mark
-----
49077F Nozzle set up
Error in recognization of the existence of Noz
-----
490780 Nozzle set up
Recognization of the existence of Noz has not finished within predetermined time
-----
490781 Nozzle set up
Error in recognizing the existence of Noz
-----
490782 Nozzle set up
Error in recognizing Noz ID
-----
490783 Nozzle set up
Recognizing Noz ID has not finished within predetermined time
-----
490784 Nozzle set up
Error in recognizing of Noz ID
-----
490785 Nozzle set up
Time-out of starting Side View Camera detect
-----
490786 Nozzle set up
Time-out of reading out the result of Side View Camera detect
-----
490787 Nozzle set up
Error in the result of Side View Camera detect
-----
490788 Nozzle set up
Time-out of starting Side View Camera detect (Noz diameter Recog)
-----
490789 Nozzle set up
Time-out of reading out the result of Side View Camera detect (Noz diameter Recog)
-----
49078A Nozzle set up
Error in the result of Side View Camera detect (Noz diameter Recog)
-----
49078B Nozzle set up
Failed in getting Noz type Data.
-----
49078C Nozzle set up
Exchanging Noz has not started within predetermined time
-----
EUKYX
3-85199-4100
3.8 Automatic Adjustment
Error ID Error Name, Description, Cause, and Remedy
49078D Nozzle set up
Exchanging Noz has not finished within predetermined time
-----
49078E Nozzle set up
Error in setting Drive Wave of HL-axis
-----
49078F Nozzle set up
Error in setting Drive Wave of NL-axis
-----
490790 Nozzle set up
Error in setting Drive Wave of L-axis
-----
490791 Nozzle set up
Error in coordinate calculation of shifting the Origin
-----
490792 Nozzle set up
Error in setting Sequence Data of HL-axis
-----
490793 Nozzle set up
Error in HL-axis operating
-----
490794 Nozzle set up
Error in L-axis operating
-----
490795 Nozzle set up
Error in the nozzle stocker mark recog. There is a possibility that the stocker type is wrong.
Please confirm that the set stocker in the unit replace screen is the same as the stocker
type of the device. Please clean it up if there is no problem.
490796 Nozzle set up
It is impossible to place a nozzle whose end type is set besides [standard] adjacent to a
head.
-----
490797 Nozzle set up
It stopped by nozzle interference check.
Perform zeroing.
490798 Nozzle set up
Error in communication with recognition.
-----
490799 Nozzle set up
Time-out of communication with recognition.
-----
49079a Nozzle set up
Error in capturing a image with component recognizing camera.
-----
EUKYX
3-86199-4100
3.8 Automatic Adjustment
Error ID Error Name, Description, Cause, and Remedy
49079b Nozzle set up
To capture a image with component recognizing camera is not complete with the
predetermined time.
-----
49079c Nozzle set up
Error in recognition of nozzle position.
-----
49079d Nozzle set up
Time-out of recognition of nozzle position.
-----
49079e Nozzle set up
Failed in nozzle position teaching. Please confirm Nozzle ID, and then replace a nozzle.
-----
49079f Nozzle set up
To set nozzle position data failed.
-----
4907A0 Nozzle set up
The nozzle stocker which is not for replace exists on input position.
Please perform all zeroing.
490801 Program -change linked operation
Program-change linked operation has not finished within appointed time.
-----
496001 Conveyor Width Backup Pin detected
Backup Pin/Jig was detected during N1_W1-axis operating.
Please remove the Backup Pin\Jig from Backup Base. Or, confirm whether Sensor has error
or not.
496002 Conveyor Width Backup Pin detected
Backup Pin/Jig was detected during N1_W2-axis operating.
Please remove the Backup Pin\Jig from Backup Base. Or, confirm whether Sensor has error
or not.
496003 Conveyor Width Backup Pin detected
Backup Pin/Jig was detected during N1_W3-axis operating
Please remove the Backup Pin\Jig from Backup Base. Or, confirm whether Sensor has error
or not.
496101 Conveyor Width W1 Error
Drive Alarm during Conveyor Width W1 axial operation.
Confirm reset Method of detailed Sub-system error counts of Alarm.
496102 Conveyor Width W1 Error
Conveyor Width W1-axis could not start
A state in which the operating command is not normally accepted.
1. Confirm connection to communication cable.
2. Confirm Power supply(24V).
3. Confirm the communication setting of PCI board.
4. Confirm the address of driver and communication rate setting.