Error ID Error Name, Description, Cause, and Remedy
497005 On manual operation Alarm
Over-current
Error in Motor output line. Check out the motor wiring,
497006 On manual operation Alarm
Limit Sensor(+) was detected.
+LS signal was detected for moving for (+).
Please check the dirt of +LS sensor, disconnection.
497007 On manual operation Alarm
Limit Sensor(-) was detected.
-LS signal was detected for moving for (-).
Please check the dirt of -LS sensor, disconnection.
497008 On manual operation Alarm
Motor disconnection was detected
Disconnection to motor was detected.(Only stop mode)
Check the motor wiring.
497009 On manual operation Alarm
Error in Control Power Voltage
Control power for driver dropped. Check out the Power supply line.(24V Line)
49700a On manual operation Alarm
-----
Reserved Function of driver. Please make inquiries when error is detected.
49700b On manual operation Alarm
-----
Reserved Function of driver. Please make inquiries when error is detected.
49700c On manual operation Alarm
-----
Reserved Function of driver. Please make inquiries when error is detected.
49700d On manual operation Alarm
-----
Reserved Function of driver. Please make inquiries when error is detected.
49700e On manual operation Alarm
-----
Reserved Function of driver. Please make inquiries when error is detected.
49700f On manual operation Alarm
System Error
System Error of internal driver. Driver error is supposed if this problem happens frequently.
497101 Before setup P.C.B. detected
PCB was detected on Input conveyor.
Can not execute Conveyor width setup with the state of P.C.B. on Conveyor.
1. Remove P.C.B.
2. Please confirm that P.C.B. is existing in Machine.

EUKYX
3-100199-4100
3.8 Automatic Adjustment
Error ID Error Name, Description, Cause, and Remedy
497102 Before setup P.C.B. detected
PCB was detected on Positioning Conveyor(Input position)
Can not execute Conveyor width setup with the state of P.C.B. on Conveyor.
1. Remove P.C.B.
2. Please confirm that P.C.B. is existing in Machine.
497103 Before setup P.C.B. detected
PCB was detected on Positioning Conveyor(Output position)
Can not execute Conveyor width setup with the state of P.C.B. on Conveyor.
1. Remove P.C.B.
2. Please confirm that P.C.B. is existing in Machine.
497104 Before setup P.C.B. detected
PCB was detected on Output conveyor.
Can not execute Conveyor width setup with the state of P.C.B. on Conveyor.
1. Remove P.C.B.
2. Please confirm that P.C.B. is existing in Machine.
497105 Before setup P.C.B. detected
PCB was detected on Input conveyor of A Lane.
Can not execute Conveyor width setup with the state of P.C.B. on Conveyor.
1. Remove P.C.B.
2. Please confirm that P.C.B. is existing in Machine.
497106 Before setup P.C.B. detected
PCB was detected on Positioning Conveyor of A lane(Input position)
Can not execute Conveyor width setup with the state of P.C.B. on Conveyor.
1. Remove P.C.B.
2. Please confirm that P.C.B. is existing in Machine.
497107 Before setup P.C.B. detected
PCB was detected on Positioning Conveyor of A lane(Output position)
Can not execute Conveyor width setup with the state of P.C.B. on Conveyor.
1. Remove P.C.B.
2. Please confirm that P.C.B. is existing in Machine.
497108 Before setup P.C.B. detected
PCB was detected on Output conveyor of A Lane.
Can not execute Conveyor width setup with the state of P.C.B. on Conveyor.
1. Remove P.C.B.
2. Please confirm that P.C.B. is existing in Machine.
497109 Before setup P.C.B. detected
PCB was detected on Input conveyor of B Lane.
Can not execute Conveyor width setup with the state of P.C.B. on Conveyor.
1. Remove P.C.B.
2. Please confirm that P.C.B. is existing in Machine.

EUKYX
3-101199-4100
3.8 Automatic Adjustment
Error ID Error Name, Description, Cause, and Remedy
49710a Before setup P.C.B. detected
PCB was detected on Positioning Conveyor of B Lane(Input position).
Can not execute Conveyor width setup with the state of P.C.B. on Conveyor.
1. Remove P.C.B.
2. Please confirm that P.C.B. is existing in Machine.
49710b Before setup P.C.B. detected
PCB was detected on Positioning Conveyor of B Lane(Output position).
Can not execute Conveyor width setup with the state of P.C.B. on Conveyor.
1. Remove P.C.B.
2. Please confirm that P.C.B. is existing in Machine.
49710c Before setup P.C.B. detected
PCB was detected on Output conveyor of B Lane.
Can not execute Conveyor width setup with the state of P.C.B. on Conveyor.
1. Remove P.C.B.
2. Please confirm that P.C.B. is existing in Machine.
49710d Before setup P.C.B. detected
PCB is detected from Shuttle Conveyor in Input side.
Can not execute Conveyor width setup with the state of P.C.B. on Conveyor.
1. Remove P.C.B.
2. Please confirm that P.C.B. is existing in Machine.
49710e Before setup P.C.B. detected
PCB is detected from Shuttle Conveyor in Output side.
Can not execute Conveyor width setup with the state of P.C.B. on Conveyor.
1. Remove P.C.B.
2. Please confirm that P.C.B. is existing in Machine.
49710f Before setup P.C.B. detected
Stopper descent has not been complete.
1. Please check if stopper is broken.
2. Please check if PCB is caught in stopper.
497110 Before setup P.C.B. detected
PCB was detected on A Lane.
Can not execute Conveyor width setup with the state of P.C.B. on Conveyor.
1. Remove P.C.B.
2. Please confirm that P.C.B. is existing in Machine.
497111 Before setup P.C.B. detected
PCB was detected on B Lane.
Can not execute Conveyor width setup with the state of P.C.B. on Conveyor.
1. Remove P.C.B.
2. Please confirm that P.C.B. is existing in Machine.
497201 Error in Support pin setup
Failed in recognizing Support Pin which will be pick-up.
Open the cover and set all support pins in Stock area. Then, Please edit Stock area.