EUKYX-199-4110_G5S2_Instruction_Vol4_E - 第268页
EUKYX 3-103 199-4100 3.9 Head Relation 3.9 Hea d Relation Error ID Error Name, Description, Cause, and Remed y 4 a 0101 M otor p ositioning error Motor positioni ng error All o rigi n retur n, and, p leas e sta r t agai …

EUKYX
3-102199-4100
3.8 Automatic Adjustment
Error ID Error Name, Description, Cause, and Remedy
497202 Error in Support pin setup
Illegal support pin exists in the place where support pin will be set.
Open the cover and set all support pins in Stock area.Then, Please edit Stock area.
497203 Error in Support pin setup
Failed in pick-up support pin
There is a possibility that Support pin is falling.
Open the cover and set all support pins in Stock area. Then, edit Stock area.
497204 Error in Support pin setup
Failed in detecting support pin after set it.
There is a possibility that Support pin is falling.
Open the cover and set all support pins in Stock area. Then, edit Stock area.
497205 Error in Support pin setup
Error in detect before operation.
Please check the state of Head.
497206 Error in Support pin setup
Operation Error
There is a possibility that Support pin is falling. Open the cover and set all support pins in
Stock area. Then, edit Stock area.
497210 Error in Support pin setup
There is not enough support pin for arrangement.
Open the cover and set support pins of appropriate number in Stock area. Then, edit Stock
area.
497211 Error in Support pin setup
There is not sufficient space to evacuate surplus support pins.
Please arrange support pins of the number used exactly.
497212 Error in Support pin setup
Failure in exchanging data
-----

EUKYX
3-103199-4100
3.9 Head Relation
3.9 Head Relation
Error ID Error Name, Description, Cause, and Remedy
4a0101 Motor positioning error
Motor positioning error
All origin return, and, please start again.
4a0102 Motor positioning error
Other axis positioning timeout
-----
4a0201 Motor positioning timeout
Motor positioning timeout
-----
4a0301 Motor start condition error
Motor start condition error
-----
4a0401 Motor mode set error
Motor mode set error
-----
4a0501 Motor mode set timeout
Motor mode set timeout
-----
4a0601 Motor start command error
Motor start command error
-----
4a0701 Motor start command timeout
Motor start command timeout
-----
4a2101 Valve Changes error
Valve switching error
-----
4a2201 Air Vacuum Change error
Air vacuum switching error
-----

EUKYX
3-104199-4100
3.10 Others
3.10 Others
Error ID Error Name, Description, Cause, and Remedy
4b0201 Feeder communication Error.
Communication with the feeder has an error.
Please check the number of component remain.
4b0204 Feeder communication Error.
Communication with feeder was not completed within predetermined time. (Please take out
and insert feeder.)
-----
4b0205 Feeder communication Error.
Failed in processing information read.
Please put the Cart down, or pull out and insert Feeder.
4b0206 Feeder communication Error.
Failed in Program-changed.
Please put the Cart down, or pull out and insert Feeder.
4b0207 Feeder communication Error.
Failed in Splicing survey setup.
Please put the Cart down, or pull out and insert Feeder.
4b0208 Feeder communication Error.
Cannot send it because of Error of Serial Communication process.
Please put the Cart down, or pull out and insert Feeder.
4b0209 Feeder communication Error.
-----
Please take out a feeder once, and then take it in
4b0302 Feeder Base
The feeder unclamp operation was not completed within predetermined time.
-----
4b0304 Feeder Base
The feeder clamp operation was not completed within predetermined time.
-----
4b0305 Feeder Base
The feeder base ascent operation was not completed within predetermined time.
Check the feeder base upper limit position.[B0614][B0914]
4b0306 Feeder Base
The feeder base descent operation was not completed within predetermined time.
Check the feeder base lower limit position.
4b0307 Feeder Base
The connector (Block1) for the feeder base worked off. Do not remove the connector during
feeder base ascent.[B0916]
Connect the connector (Block1) for the feeder base to the machine main body.
4b0308 Feeder Base
The connector (Block2) for the feeder base worked off. Do not remove the connector during
feeder base ascent.[B0916]
Connect the connector (Block2) for the feeder base to the machine main body.
4b0310 Feeder Base
The power was not turned on, or emergency stop was detected.
Please turn on the machine after confirm that Emergency Stop button is not pressed.