EUKYX-199-4110_G5S2_Instruction_Vol4_E - 第271页
EUKYX 3-106 199-4100 3.10 Others Error ID Error Name, Description, Cause, and Remedy 4 b 0 31D Feeder Base Car t ri sing s top pe d (Bl oc k1 ) . Cann ot rele ase t he safe ty c over fo r the ca r t in the o pp osite s i…

EUKYX
3-105199-4100
3.10 Others
Error ID Error Name, Description, Cause, and Remedy
4b 0 311 Feeder Base
Feeder Cart could not be detected.
Please execute operation again after setting Feeder Cart in predetermined place. Please
confirm whether it set in if the set is already done well.
4b0312 Feeder Base
Connector of Feeder Cart is not connected
Please execute operation again after connecting connector of Feeder Cutter.
4b0313 Feeder Base
NL-axis interlock was detected
Please execute zeroing when NL-axis is fallen.
4b0314 Feeder Base
Error in Feeder Base movement
----
4b0315 Feeder Base
Time-out in Clamp Movement of Elevator Unit
----
4b0316 Feeder Base
Time-out in Unclamp Movement of Elevator Unit
----
4b0317 Feeder Base
Illegal current position of Feeder base (Block1)
Please confirm Feeder base, and the sensor of Cylinder Upper limit detection[B0614],
Cylinder Lower limit detection[B0615].
4b0318 Feeder Base
Illegal current position of Feeder base (Block2)
Please confirm Feeder base, and the sensor of Cylinder Upper limit detection[B0614],
Cylinder Lower limit detection[B0615].
4b0319 Feeder Base
Positioning dropping prevention stopper(Block1) cannot cancel lock.
Please confirm the state of Feeder base and detect sensor of positioning drop prevention
lock[B0912][B0913]
4b031A Feeder Base
Positioning dropping prevention stopper(Block2) cannot cancel lock.
Please confirm the state of Feeder base and detect sensor of positioning drop prevention
lock[B0612][B0613]
4b031B Feeder Base
Positioning dropping prevention stopper(Block1) cannot lock.
Please confirm the state of Feeder base and detect sensor of positioning drop prevention
lock[B0912][B0913]
4b031C Feeder Base
Positioning dropping prevention stopper(Block2) cannot lock.
Please confirm the state of Feeder base and detect sensor of positioning drop prevention
lock[B0612][B0613]

EUKYX
3-106199-4100
3.10 Others
Error ID Error Name, Description, Cause, and Remedy
4b031D Feeder Base
Cart rising stopped(Block1).
Cannot release the safety cover for the cart in the opposite side is in process.
The process stopped because there is a possibility that something is placed between Cart
and the safety cover.
-----
4b031E Feeder Base
Cart rising stopped(Block2).
Cannot release the safety cover for the cart in the opposite side is in process.
The process is stopped because there is a possibility that something is placed between
Cart and the safety cover.
-----
4b031F Feeder Base
Failed that Automatic safety cover opening starts up. The process is stopped because there
is a possibility that something is placed between Cart and the safety cover.
-----
4b0320 Feeder Base
Automatic safety cover opening is not completed in predetermined time. The process is
stopped because there is a possibility that something is placed between cart and the safety
cover.
-----
4b0321 Feeder Base
Failed in Automatic safety cover opening (Release Lock).
The process is stopped because there is a possibility that something is placed between cart
and the safety cover.
-----
4b0322 Feeder Base
Cannot distinguish a cart(Block1). Please operate it again.
-----
4b0323 Feeder Base
Cannot distinguish a cart(Block2). Please operate it again.
-----
4b0501 Manual alignment Error
Operation was not completed within predetermined time.
-----
4b050f Manual alignment Error
Error was detected during operation.
-----
4b0701 Connection Error.
Failed in communications with the Control CPU.
-----
4b0702 Connection Error.
Failed in communications with the Recog. CPU.
-----

EUKYX
3-107199-4100
3.10 Others
Error ID Error Name, Description, Cause, and Remedy
4b0801 Side View Camera operation is abnormal.
Side View Camera was found abnormality while measuring.
There is a possibility of Light Emitter and Receiver broken. Please confirm Error from Log
Request Screen(Unit adjustment -> Side view camera Screen)
4b0802 Side View Camera operation error
The measurement by the side view camera was not completed on time.
Communication connector of Side view camera P.C.B is taken off. Please confirm whether
the items of LS-RLS-S(Device Check -> List) is Yellow. HLS communication cable could not
be connected and such like things.
4b0803 Side View Camera operation error
There is a problem in the values measured by the side view camera.
Light Emitter and Receiver could have flaw and soil. Please clean it up. Please press
[Operation] on the screen(Unit adjustment -> Side view camera -> Detection test Screen)
and confirm whether there is an error
4b0804 Side View Camera operation error
There is a problem in the values measured by the side view camera.
There is a possibility of Side View CameraP.C.B. broken
4b0805 Side View Camera operation error
There is a problem in the values measured by the side view camera.
A small light quantity of Light Emitter. Please exchange Light Emitter.
4b0806 Side View Camera operation error
There is a problem in the values measured by the side view camera.
There is a possibility of Side View Camera P.C.B. broken. Either, Please update Version on
the screen(Unit adjustment -> Side view camera -> Correct data read Screen)
4b0807 Side View Camera operation error
There is a problem in the values measured by the side view camera.
Please confirm Error from Log Request Screen(Unit adjustment -> Side view camera
Screen). Either, please confirm whether the items of LS-RLS-S(Device Check -> List) is
Yellow.
HLS communication cable could not be connected and such like things.
4b0808 Side View Camera operation error
There is a problem in the values measured by the side view camera.
Please confirm Error from Log Request Screen(Unit adjustment -> Side view camera
Screen). Either, please confirm whether the items of LS-RLS-S(Device Check -> List) is
Yellow.
HLS communication cable could not be connected and such like things.
4b0809 Side View Camera operation error
There is a problem in the side view camera.(Strobe Signal did not turn off within
predetermined time.)
Please confirm Error from Log Request Screen(Unit adjustment -> Side view camera
Screen). Either, please confirm whether the items of LS-RLS-S(Device Check -> List) is
Yellow.
HLS communication cable could not be connected and such like things.
4b0c01 Nozzle Confirmation Error before pick up comp (Detect After Placement)
Because a component was found on a nozzle, it stopped after disposal.
The result could have some problems.
Please check placement state on placement step recovery screen.