EUKYX-199-4110_G5S2_Instruction_Vol4_E - 第291页
EUKYX 3-126 199-4100 3.12 Automatic Operation Error Error ID Error Name, Description, Cause, and Remedy 5 11 0 0 4 Head 1 P reparation Error The re is a po ssi bili ty t hat Noz zle is fa llin g whil e pro ces sing t he …

EUKYX
3-125199-4100
3.12 Automatic Operation Error
3.12 Automatic Operation Error
Error ID Error Name, Description, Cause, and Remedy
510a01 Feeder Pocket recog Error
Abnormality occurred in process of recognizing Feeder Pocket.
-----
510b01 Auto Run Error
Master bad mark detection is abnormal.
-----
510b02 Auto Run Error
Bad mark detection is abnormal.
-----
510e01 Nozzle air blow Error(Head1)
Because abnormality had occurred while processing the nozzle air blow, processing was
interrupted.
-----
510e02 Nozzle air blow Error(Head1)
Because abnormality had occurred while processing the nozzle air blow, processing was
interrupted.
-----
510e03 Nozzle air blow Error(Head1)
Because abnormality had occurred while processing the nozzle air blow, processing was
interrupted.
-----
510f01 Nozzle air blow Error(Head2)
Because abnormality had occurred while processing the nozzle air blow, processing was
interrupted.
-----
510f02 Nozzle air blow Error(Head2)
Because abnormality had occurred while processing the nozzle air blow, processing was
interrupted.
-----
510f03 Nozzle air blow Error(Head2)
Because abnormality had occurred while processing the nozzle air blow, processing was
interrupted.
-----
5110 01 Head1 Preparation Error
Because abnormality had occurred while processing the preparation, processing was
interrupted.
-----
5110 02 Head1 Preparation Error
Because abnormality had occurred while processing the preparation, processing was
interrupted.
-----
5110 03 Head1 Preparation Error
Because abnormality had occurred while processing the preparation, processing was
interrupted.
-----

EUKYX
3-126199-4100
3.12 Automatic Operation Error
Error ID Error Name, Description, Cause, and Remedy
5110 04 Head1 Preparation Error
There is a possibility that Nozzle is falling while processing the preparation. Please confirm
the placed Nozzle on Head.
-----
511101 Head2 Preparation Error
Because abnormality had occurred while processing the preparation, processing was
interrupted.
-----
511102 Head2 Preparation Error
Because abnormality had occurred while processing the preparation, processing was
interrupted.
-----
511103 Head2 Preparation Error
Because abnormality had occurred while processing the preparation, processing was
interrupted.
-----
511104 Head2 Preparation Error
There is a possibility that Nozzle is falling while processing the preparation. Please confirm
the placed Nozzle on Head.
-----
511201 Transfer Section's Preparation Error
Upward Limit and Downward Limit on PCB Stopper(L) are detected simultaneously.
Please check out the wiring and adjust Limits.
511202 Transfer Section's Preparation Error
Upward movement on PCB Stopper(L) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511203 Transfer Section's Preparation Error
Downward movement on PCB Stopper(L) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511204 Transfer Section's Preparation Error
Upward Limit and Downward Limit on PCB Stopper(R) are detected simultaneously.
Please check out the wiring and adjust Limits.
511205 Transfer Section's Preparation Error
Upward movement on PCB Stopper(R) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511206 Transfer Section's Preparation Error
Downward movement on PCB Stopper(R) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511207 Transfer Section's Preparation Error
Upward Limit and Downward Limit on PCB Stopper(AL) are detected simultaneously.
Please check out the wiring and adjust Limits.
511208 Transfer Section's Preparation Error
Upward movement on PCB Stopper(AL) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511209 Transfer Section's Preparation Error
Downward movement on PCB Stopper(AL) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.

EUKYX
3-127199-4100
3.12 Automatic Operation Error
Error ID Error Name, Description, Cause, and Remedy
511210 Transfer Section's Preparation Error
Upward Limit and Downward Limit on PCB Stopper(AR) are detected simultaneously.
Please check out the wiring and adjust Limits.
511211 Transfer Section's Preparation Error
Upward movement on PCB Stopper(AR) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511212 Transfer Section's Preparation Error
Downward movement on PCB Stopper(AR) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511213 Transfer Section's Preparation Error
Upward Limit and Downward Limit on PCB Stopper(BL) are detected simultaneously.
Please check out the wiring and adjust Limits.
511214 Transfer Section's Preparation Error
Upward movement on PCB Stopper(BL) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511215 Transfer Section's Preparation Error
Downward movement on PCB Stopper(BL) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511216 Transfer Section's Preparation Error
Upward Limit and Downward Limit on PCB Stopper(BR) are detected simultaneously.
Please check out the wiring and adjust Limits.
511217 Transfer Section's Preparation Error
Upward movement on PCB Stopper(BR) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511218 Transfer Section's Preparation Error
Downward movement on PCB Stopper(BR) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511219 Transfer Section's Preparation Error
Upward Limit and Downward Limit on PCB Stopper(REV) are detected simultaneously.
Please check out the wiring and adjust Limits.
511220 Transfer Section's Preparation Error
Upward movement on PCB Stopper(REV) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511221 Transfer Section's Preparation Error
Downward movement on PCB Stopper(REV) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511222 Transfer Section's Preparation Error
Upward Limit and Downward Limit on PCB Stopper(AREV) are detected simultaneously.
Please check out the wiring and adjust Limits.
511223 Transfer Section's Preparation Error
Upward movement on PCB Stopper(AREV) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511224 Transfer Section's Preparation Error
Downward movement on PCB Stopper(AREV) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.