EUKYX-199-4110_G5S2_Instruction_Vol4_E - 第306页
EUKYX 3-141 199-4100 3.13 Auto T eaching Error ID Error Name, Description, Cause, and Remedy 6 0 1a 0 b S ide v iew c amer a cor rec tio n re-te ach Of fs et c orre ct ion c an not b e co mple ted. Ple ase u se the b ig …

EUKYX
3-140199-4100
3.13 Auto Teaching
Error ID Error Name, Description, Cause, and Remedy
601311 Noz stocker offset teaching
Error of output-movement of Nozzle Stocker
-----
601401 Teaching Comp. Recog. Camera Magnification Teach
Time-out of communication with recognition.
Is there Network with Recognition? Please check.
601402 Teaching Comp. Recog. Camera Magnification Teach
Error of Recognition Command response
-----
601a01 Side view camera correction re-teach
The Side View Camera reading is abnormal.
Please confirm whether the nozzle has adhered to the position.
601a02 Side view camera correction re-teach
Offset correction can not be completed. Please use the big nozzle(HA05) teach again and
adjust the light & receive optical Axis
-----
601a03 Side view camera correction re-teach
Nozzle can not be detected.
-----
601a04 Side view camera correction re-teach
Side View Camera Control is abnormal.
-----
601a05 Side view camera correction re-teach
Offset correction can not be completed. Please use the big nozzle(HA05) teach again and
adjust the light & receive optical Axis(All samples are E/R-Err7)
-----
601a06 Side view camera correction re-teach
Offset correction can not be completed. Please use the big nozzle(HA05) teach again and
adjust the light & receive optical Axis(All samples are E/NR-Err8)
Offset correction can not be completed. Please use the big nozzle(HA05) teach
-----
601a07 Side view camera correction re-teach
again and adjust the light & receive optical Axis(Edge detect error-Err9)
-----
601a08 Side view camera correction re-teach
Offset correction can not be completed. Please use the big nozzle(HA05) teach again and
adjust the light & receive optical Axis(Insufficient samples-Err10)
-----
601a09 Side view camera correction re-teach
Offset correction can not be completed. Please use the big nozzle(HA05) teach again and
adjust the light & receive optical Axis(Insufficient correcting samples-Err14)
-----
601a0a Side view camera correction re-teach
Offset correction can not be completed. Please use the big nozzle(HA05) teach again and
adjust the light & receive optical Axis(Fail to create correction-Err15)
-----

EUKYX
3-141199-4100
3.13 Auto Teaching
Error ID Error Name, Description, Cause, and Remedy
601a0b Side view camera correction re-teach
Offset correction can not be completed. Please use the big nozzle(HA05) teach again and
adjust the light & receive optical Axis(Accuracy check NG-Err16)
-----
601a0c Side view camera correction re-teach
Offset correction can not be completed. Please use the big nozzle(HA05) teach again and
adjust the light & receive optical Axis(Fail to save-Err17)
-----
601a0d Side view camera correction re-teach
The measurement value of the nozzle is not within 0.2mm to 0.6mm.
Adjust the height of the side view camera otherwise, replace it.
601a0e Side view camera correction re-teach
The Side View Camera control has an error.(err2, err3)
All E/NR Error. There is a possibility that Light Emitter or Receiver is broken.
601a0f Side view camera correction re-teach
The Side View Cameracontrol has an error.(err1)
Could be P.C.B. Error
601a10 Side view camera correction re-teach
The Side View Camera control has an error.(err4)
A quantity of light emitter is dropping. There is a possibility of Light Emitter broken.
601a11 Side view camera correction re-teach
No strobe response
Please confirm the wiring of HLS. Either, confirm P.C.B. address.
601f01 NL Axis offset teach
Error before Side View Camera measurement began
-----
601f02 NL Axis offset teach
ODD Noz is placed on Head, or error is detected during side view camera.
-----
601f03 NL Axis offset teach
Error of NS-axis movement
-----
601f04 NL Axis offset teach
Error of DD-axis movement
-----
601f05 NL Axis offset teach
Error of NL-axis movement
-----
601f06 NL Axis offset teach
Error of DD/NS-axis movement
-----
601f07 NL Axis offset teach
Time-out when Side View Camera measurement began
-----
601f08 NL Axis offset teach
Read Time-out of Side View Camera measurement
-----

EUKYX
3-142199-4100
3.13 Auto Teaching
Error ID Error Name, Description, Cause, and Remedy
601f09 NL Axis offset teach
Time-out of NL-axis movement
-----
601f0a NL Axis offset teach
Time-out of DD/NS-axis movement
-----
601f0b NL Axis offset teach
Error during Teach
-----
602001 Writing Side View Camera Program
Fail to write Side View Camera Program
-----
602101 Teaching Tray Pallet Transition
Elevator Check Error
-----
602102 Teaching Tray Pallet Transition
Error in Elevator axis movement position calculating
Please adjust the caster's height of elevator unit to make it higher.
602103 Teaching Tray Pallet Transition
Elevator axis Movement Error
-----
602104 Teaching Tray Pallet Transition
Time-out in elevator axis movement
-----
602105 Teaching Tray Pallet Transition
Elevator axis Movement Error
-----
602106 Teaching Tray Pallet Transition
Time-out in elevator axis movement
-----
602107 Teaching Tray Pallet Transition
Elevator axis Movement Error
-----
602108 Teaching Tray Pallet Transition
Error in elevator Stop Auto Run
-----
602109 Teaching Tray Pallet Transition
Time-out in elevator Stop Auto Run
-----
60210A Teaching Tray Pallet Transition
Error in getting current position of Elevator axis
-----
60210B Teaching Tray Pallet Transition
Program Error
-----