EUKYX-199-4110_G5S2_Instruction_Vol4_E - 第332页
EUKYX 3-167 199-4100 3.18 System Error 3. 1 8 System Error Error ID Error Name, Description, Cause, and Remedy FE 0101 Auto C ont rol Err or In aut o con trol t he op erat ion c an't b e co ntinu ed Err or . Plea se…

EUKYX
3-166199-4100
3.17 ACV
Error ID Error Name, Description, Cause, and Remedy
740708 ACV server timeout
There was no communication response from the CPU1.
-----
740801 ACV check
The S/N of the machine didn't log in ACV server
-----
740802 ACV check
The S/N of the operator didn't log in ACV server
-----
740a01 ACV check
Starting of ACV tray tag reading went wrong.
-----
740f01 ACV check
Splicing registration failed.
-----
740f02 ACV check
Splicing registration failed for the unused feeder.
-----
740f03 ACV check
Abnormality was found in the connection with the ACV server. Please confirm the ACV
server. Please execute the server connection again on "MAINTENANCE"-"UNIT ADJ"-"ACV
ADJ"-screen after it confirms it.
-----

EUKYX
3-167199-4100
3.18 System Error
3.18 System Error
Error ID Error Name, Description, Cause, and Remedy
FE0101 Auto Control Error
In auto control the operation can't be continued Error.
Please start again. In recurring, please try the method indicated below. / Optimization after
one change of use of a block sort, the capture mode of component library, PEC recognition
beam, sequence, PCB finishing position, or nozzle configuration of a pattern program. /
Change of Speed in Opr.Mode.
FE0102 Auto Control Error
Stopped by the interference check.
Please restart it.
FE0201 XY Control Error
Error in XY Control Sequence.
Please start again. In recurring, please try the method indicated below. / Optimization after
one change of use of a block sort, the capture mode of component library, PEC recognition
beam, sequence, PCB finishing position, or nozzle configuration of a pattern program. /
Change of Speed in Opr.Mode.
FE0202 XY Control Error
Error in interface check of XY Control Sequence.
Please start again. In recurring, please try the method indicated below. / Optimization after
one change of use of a block sort, the capture mode of component library, PEC recognition
beam, sequence, PCB finishing position, or nozzle configuration of a pattern program. /
Change of Speed in Opr.Mode.
FE0203 XY Control Error
Timeout in XY Control
Please start again. In recurring, please try the method indicated below. / Optimization after
one change of use of a block sort, the capture mode of component library, PEC recognition
beam, sequence, PCB finishing position, or nozzle configuration of a pattern program. /
Change of Speed in Opr.Mode.
FE0301 Control System Error
Error in control system. Control system restarts.
There is a possibility that components fall on PCB or in the device when components are
still picked up. Please check it.
FE0302 Control System Error
Control system failed to restart. Please shut down it.
Please start again. In recurring, please try the method indicated below. / Optimization after
one change of use of a block sort, the capture mode of component library, PEC recognition
beam, sequence, PCB finishing position, or nozzle configuration of a pattern program. /
Change of Speed in Opr.Mode.

199-4100
Chapter 4
Troubleshooting from Recognition Error IDs
This chapter describes the troubleshooting from recognition error
IDs.
1. Description of Recognition Error ID (Example)
2. Recognition Error IDs and Controlled Areas
3. Recognition Error IDs and Remedial Procedures
EUKYX