EUKYX-199-4110_G5S2_Instruction_Vol4_E - 第333页
199-4100 Chapt er 4 T roubleshooting from Recogniti on Error IDs This chapter describes the troubleshooting from recognition error IDs. 1. Description of Recognition Error ID (Example) 2. Recognition Error IDs and Contro…

EUKYX
3-167199-4100
3.18 System Error
3.18 System Error
Error ID Error Name, Description, Cause, and Remedy
FE0101 Auto Control Error
In auto control the operation can't be continued Error.
Please start again. In recurring, please try the method indicated below. / Optimization after
one change of use of a block sort, the capture mode of component library, PEC recognition
beam, sequence, PCB finishing position, or nozzle configuration of a pattern program. /
Change of Speed in Opr.Mode.
FE0102 Auto Control Error
Stopped by the interference check.
Please restart it.
FE0201 XY Control Error
Error in XY Control Sequence.
Please start again. In recurring, please try the method indicated below. / Optimization after
one change of use of a block sort, the capture mode of component library, PEC recognition
beam, sequence, PCB finishing position, or nozzle configuration of a pattern program. /
Change of Speed in Opr.Mode.
FE0202 XY Control Error
Error in interface check of XY Control Sequence.
Please start again. In recurring, please try the method indicated below. / Optimization after
one change of use of a block sort, the capture mode of component library, PEC recognition
beam, sequence, PCB finishing position, or nozzle configuration of a pattern program. /
Change of Speed in Opr.Mode.
FE0203 XY Control Error
Timeout in XY Control
Please start again. In recurring, please try the method indicated below. / Optimization after
one change of use of a block sort, the capture mode of component library, PEC recognition
beam, sequence, PCB finishing position, or nozzle configuration of a pattern program. /
Change of Speed in Opr.Mode.
FE0301 Control System Error
Error in control system. Control system restarts.
There is a possibility that components fall on PCB or in the device when components are
still picked up. Please check it.
FE0302 Control System Error
Control system failed to restart. Please shut down it.
Please start again. In recurring, please try the method indicated below. / Optimization after
one change of use of a block sort, the capture mode of component library, PEC recognition
beam, sequence, PCB finishing position, or nozzle configuration of a pattern program. /
Change of Speed in Opr.Mode.

199-4100
Chapter 4
Troubleshooting from Recognition Error IDs
This chapter describes the troubleshooting from recognition error
IDs.
1. Description of Recognition Error ID (Example)
2. Recognition Error IDs and Controlled Areas
3. Recognition Error IDs and Remedial Procedures
EUKYX

EUKYX
4-1199-4100
1. Description of Recognition Error ID (Example)
1. Description of Recognition Error ID (Example)
[1]
[2]
Recognition Error ID Description of Recognition Error
050**001 Component was not found.
051**001 Component was not detected.
[1] Recognition Error ID
The recognition error IDs (IDs displayed in the "ERROR" window) are described in the numerical
order.
[2] Description of Recognition Error
Described are the contents of a recognition error that will be displayed in the "ERROR" window.