EUKYX 1-33 199-4100 4.6 Cutter Section (3 ) Pull out t he cut ter unit main bod y for ward. R emove 3 unit connection c onnect ors. At this point, mak e sure not to te ar off t he connec tor cab le by pulling them fo rci…

EUKYX
1-32199-4100
4.6 Cutter Section
4.6.2 Cutter Unit Lubrication
Cycle: Every 3 Months (Required Time : 40 minutes)
Grease: DAPHNE GREASE MP No. 1
CAUTION
After making sure that the power supply has been stopped,
start maintenance. During maintenance, do not touch the
cutter blade.
(1) Remove the truss head screws (1 each on left and right) mounting the lower slope. Loosen
the truss head screws at the bottom (1 each on left and right). Detach the lower slope.
Cutter unit
Upper slope
Lower slope
Truss head screw (front side)
Truss head screw (Bottom side)
F4A27AA
(2) Remove hex socket head cap screws mounting the cutter unit (1 each on left and right).
Hex socket head cap screw
F4A27B
Procedure

EUKYX
1-33199-4100
4.6 Cutter Section
(3) Pull out the cutter unit main body forward. Remove 3 unit connection connectors. At this
point, make sure not to tear off the connector cable by pulling them forcibly. Additionally,
take care that the connector cable is not trapped when returning the unit to the original
position.
Connection connectors (3 pcs)
Connector
cable
Front
Cutter unit main body
F4A27C
(4) Pull out the cutter unit main body forward more. Move it over the unit stopper bolts and
detach it from the machine. Make sure to grip the handles firmly in order not to drop the
cutter unit as it is heavy.
Handle
Handle
Unit stopper
bolt
Unit stopper
bolt
Front
F4A27F

EUKYX
1-34199-4100
4.6 Cutter Section
(5) Remove hex socket head cap screws (2 each on left and right) mounting the upper slope.
Detach the upper slope.
Hex socket head cap screws
Upper slope
F4A27D
(6) Remove 6 truss head screws mounting the rear cover. Detach the rear cover.
Rear cover
Truss head screws
Truss head screws
F4A27G