If this is not the placement station on which the ACT is to be performed, the plate is automatically
passed through the machine, since there is no specification by SIPLACE Pro for components to be
placed.
If no components are to be placed on the next machine either, the plate is automatically passed
through this machine, too.
On the station being in ACT mode and for which a corresponding specification for components to
be placed is available, the plate is stopped and gets placed automatically in the placement area,
see section 4.2.6.
Then the measurement is started automatically.
ACT - Accuracy Check Tool / User Manual 09/2015 Edition
51
4.2.5 Working with the ACT Function under Station Software 605.xx
NOTICE
On SIPLACE X and D machines running station software 605.xx (platform 2+), it is
necessary to install additional software on the station computer to be able to use the
ACT.
The installation is described in chapter 6.
Switch on the machine.
The station computer will boot. The user interface basic view for the SC program will soon appear.
Figure 4-27: Basic view of user interface GUI at the station
From the Optionen (Options) menu, select Bedienebene… (Access level...) (Figure 4-25).
The Bedienebene (Access level) dialog box opens.
ACT - Accuracy Check Tool / User Manual 09/2015 Edition
52
Figure 4-28: Dialog box: Access level (example SIPLACE D1)
Enable the Servicetechniker (Service) access level and confirm your entry with OK.
If a password has been defined, a dialog box will open for you to enter this password.
Enter the password and confirm with OK.
Select the Optionen Betriebsart... (Options Control mode...) menu items.
Figure 4-29: Basic view of user interface for SC program (example SIPLACE D1)
This opens the Betriebsart (Control mode) dialog box.
Select SIPLACE Pro and confirm the setting with OK.