ACT - Accurac y Check Tool / User Manual 09/2015 Edition 63 4.2.6 Working with the ACT under Station Softw are 703.xx and Higher NOTICE It is not necessary to instal l any addition al software on t he station computer o …

ACT - Accuracy Check Tool / User Manual 09/2015 Edition
62
Figure 4-41: Measurement report (log) in PDF format

ACT - Accuracy Check Tool / User Manual 09/2015 Edition
63
4.2.6 Working with the ACT under Station Software 703.xx and Higher
NOTICE
It is not
necessary to install any additional software on the station computer on machines
running version 703.xx and higher of the station software.
Requirements:
● You have already sent a placement/measurement program to the station as described in
section 4.1.
● You have set up the station as described in section 4.2.1.
Figure 4-42: Switching the user level
► Switch to the Einstellungen (Settings) view (1).
► Switch to Benutzereinstellungen (User settings) (2).
► Switch to the Service (Kunde) (Machine service) user level (3).
► To do so, enter the Service Passwort (Service password).

ACT - Accuracy Check Tool / User Manual 09/2015 Edition
64
Figure 4-43: Service Tools view
► Change to the Service view. (1).
► Click the Accuracy Check button (2).
Figure 4-44: Preparing for the accuracy check
► Now click the Prepare for accuracy check button (3).