ASM OIS/SIS Databases 14.0 ( R16 - 2) / Interface De scription 12/2016 Edition 60 8.2 OIS Relevant Mac hine Error Messag es Number Error Message 16 Seg. not airtight 28 The nozzle in the reject position is contaminated 4…

ASM OIS/SIS Databases 14.0 (R16-2) / Interface Description 12/2016 Edition
59
22
OIS_VISION_BEGIN
Vision system active
0 0 0 100
0 100
100
0
23
OIS_FUNCTION
Single functions active
0 0 0 100
0 100
100
0
24
OIS_INIT
Placement machine is initializing
0 0 0 100
0 100
100
0
25
OIS_HOLIDAY
Manual input, vacation
0 0 0 0 0 100
100
1
26
OIS_MAINTENACE
Manual input, planned maintenance
0 0 0 0 0 100
100
1
27
OIS_SETUP
Manual input, setting up machines
0 0 0 0 0 100
100
1
28
OIS_DOWN_PLAN
Manual input, planned downtime
0 0 0 0 0 100
100
1
29
OIS_DOWN_ILL
Manual input, unplanned downtime
0 0 0 0 0 100
100
1
30
OIS_PROTOTYPE
Manual input, product move
0 0 0 0 0 100
100
1
Table 8-1: Assignment of states to time slices
Configuration of shares of time
A customer can save a time model centrally in the database. This customer configuration is shown
in the following tables:
● STATE
● STATESHARE
The customer configuration can be accessed via these views.

ASM OIS/SIS Databases 14.0 (R16-2) / Interface Description 12/2016 Edition
60
8.2 OIS Relevant Machine Error Messages
Number Error Message
16
Seg. not airtight
28
The nozzle in the reject position is contaminated
43
Component not at nozzle after pick-up
44
Component not at nozzle before placement
48
Results of vacuum measurement of pick-up and reject station reversed
103
Pitch of a lead group outside tolerance
121
Lead tip: No result
203
Track deactivated by operator
272
No measurement from vision system
398
Coplanarity: Row not available
403
Coplanarity: Too many leads measured
455
Component not on nozzle during placement
486
Coplanarity: Component outside measuring range
487
Coplanarity: Lead missing or row not measured correctly
488
Coplanarity: Measuring on one lead finished
489
Coplanarity: Lead outside position tolerance
490
Coplan.: Placement level not found
499
Lead tip: component outside tolerance
500
Lead tip: evaluation not possible
503
Waffle pack tray is empty
2000
Component outside feed tolerance
2001
Component outside feed tolerance (Size)
2002
Component outside feed tolerance (Row)
2003
Component outside feed tolerance (Corner)
2004
Component outside feed tolerance (Lead)
2005
Component outside feed tolerance (Grid)
2006
Component outside feed tolerance (Ball)
2007
Component outside feed tolerance
2008
Component outside feed tolerance (Size)
2009
Component outside feed tolerance (Row)
2010
Component outside feed tolerance (Corner)
2011
Component outside feed tolerance (Lead)
2012
Component outside feed tolerance (Grid)
2013
Component outside feed tolerance (Ball)

ASM OIS/SIS Databases 14.0 (R16-2) / Interface Description 12/2016 Edition
61
2014
Quality too low during optical centering
2015
Quality too low during optical centering (Size)
2016
Quality too low during optical centering (Row)
2017
Quality too low during optical centering (Corner)
2018
Quality too low during optical centering (Lead)
2019
Quality too low during optical centering (Grid)
2020
Quality too low during optical centering (Ball)
2021
Component length outside tolerance
2022
Component length outside tolerance (Size)
2023
Component length outside tolerance (Row)
2024
Component length outside tolerance (Corner)
2025
Component length outside tolerance (Lead)
2026
Component length outside tolerance (Grid)
2027
Component length outside tolerance (Ball)
2028
Component width outside tolerance
2029
Component width outside tolerance (Size)
2030
Component width outside tolerance (Row)
2031
Component width outside tolerance (Corner)
2032
Component width outside tolerance (Lead)
2033
Component width outside tolerance (Grid)
2034
Component width outside tolerance (Ball)
2035
Number of leads on component not correct. Inaccurate calibration
2036
Number of leads on component not correct (Corner)
2037
Number of leads on component not correct (Lead)
2038
Orthogonality error during component measuring
2039
Orthogonality error during component measuring (Corner)
2040
Orthogonality error during component measuring (Lead)
2041
Orthogonality error during component measuring (Lead)
2042
Component angle outside tolerance
2043
Component angle outside tolerance (Size)
2044
Component angle outside tolerance (Row)
2045
Component angle outside tolerance (Corner)
2046
Component angle outside tolerance (Lead)
2047
Component angle outside tolerance (Grid)
2048
Position: evaluation not possible
2049
Position: evaluation not possible (Size)
2050
Position: evaluation not possible (Row)
2051
Position: evaluation not possible (Corner)
2052
Position: evaluation not possible (Lead)