Technical Data
Electrical Ratings, Energy Consumption and
Compressed Air Supply
Electrical ratings
Supply voltage Fuses
Main power supply
3 x 200 V~ ± 10 %; 50 Hz (North Japan)
3 x 220 V~ ± 10 %; 60 Hz (South Japan)
3 x 208 V~ ± 10 %; 50/60 Hz (U.S.A)
3 x 230 V~ ± 10 %; 50/60 Hz
3 x 380 V~ ± 10 %; 50/60 Hz
3 x 400 V~ ± 10 %; 50/60 Hz (Europe)
3 x 415 V~ ± 10 %; 50/60 Hz
3 x 25 A to max. 3 x 32 A characteristic C
3 x 25 A to max. 3 x 32 A characteristic C
3 x 25 A to max. 3 x 32 A characteristic C
3 x 25 A to max. 3 x 32 A characteristic C
3 x 16 A characteristic C
3 x 16 A characteristic C
3 x 16 A characteristic C
Power connector
Cable 5 x 4 mm² 5 x 32 A (3 x 200 V~ / 208 V~ / 220 V~/ 230 V ~)
Cable 5 x 4 mm² with CEKON connector 5 x 16 A (3 x 380 V~ / 400 V~ / 415 V~/ V ~)
Energy consumption
Energy consumption
without vacuum pump
Energy consumption
with vacuum pump
a
a) Vacuum pump for C&P20 head only.
Nominal apparent
power
SIPLACE DX1
SIPLACE DX2
1.8 kVA
2.4 kVA
3.0 kVA
3.6 kVA
Nominal active power
SIPLACE DX1
SIPLACE DX2
1.2 kW
1.6 kW
2.0 kW
2.4 kW
Compressed air supply
Compressed air pres-
sure values
p
min
p
max
0.5 MPa = 5.0 bar
1.0 MPa = 10 bar
Operating pressure
0.48 MPa ± 0.025 MPa (4.8 bar ± 0.25 bar)
Compressed air con-
nection
R 3/4" internal thread (pipe thread) with 1/2" hose connector
Compressed air consumption
b
b) Average consumption values.
Placement head
configuration
Compressed air
consumption-
c
without vacuum pump
c) Under normal atmospheric conditions at 20°C and 1013 hPa.
Compressed air consumption
c
with vacuum pump
a
SIPLACE DX2
SIPLACE DX1
C&P20 / C&P20
C&P20/C&P12
C&P12/C&P12
TH/C&P12
C&P20
C&P12
TH
490 Nl/min
520 Nl/min
550 Nl/min
375 Nl/min
280 Nl/min
275 Nl/min
100 Nl/min
200 Nl/min
100 Nl/min
Compressed air specification according to ISO 8573
Particle size (ISO Class 3)
5 µm
Particle density (ISO Class 3)
5 mg/m³
Maximum oil content (ISO class 1)
Particle density 0.01 mg/m³
Pressure dewpoint (ISO class 4)
Dewpoint + 3°
52
Technical Data SIPLACE DX1/DX2
Electrical Ratings, Energy Consumption and
Compressed Air Supply
1 = Electrical connection
2 = Compressed air connection
The connections are run into the machine from below and then connected to the power
supply of pneumatic unit.
53
Technical Data
Dimensions and Setup Conditions
Length 1450 mm
Width
Standard configuration
a
a) Standard configuration: 1 DX table inside and 1 DX table outside.
2508 mm
2425 mm
Height of the machine
with indicator lamp
with folded-up protective covers
(for PCB conveyor height 900 mm)
(for PCB conveyor height 930 mm)
(for PCB conveyor height 950 mm)
max. 1765 mm
1980 mm
2010 mm
2030 mm
Machine ground clearance
(for PCB conveyor height 900 mm)
(for PCB conveyor height 930 mm)
(for PCB conveyor height 950 mm)
120 mm ± 15 mm
150 mm ± 15 mm
170 mm ± 15 mm
Weight
a
DX1 2x DX tables 60 (empty)
DX1 with 2x DX tables 60 (fully configured)
DX2 2x DX tables 60 (empty)
DX2 with 2x DX tables 60 (fully configured)
2482 kg
2806 kg
2532 kg
2856 kg
Location
a
SIPLACE DX1/DX2 3.71 m²
Load per unit area
a
The load per unit area calculation included an additional working
space of 0.5 m on each side of the machine.
SIPLACE DX1
SIPLACE DX2
6.1 kN/m²
6.2 kN/m²
Load per unit area
a
The load per unit area calculation includes an additional working
space of 1.0 m on each side of the machine.
SIPLACE DX1
SIPLACE DX2
4.7 kN/m²
4.8 kN/m²
Number of machine feet 4
Maximum noise emissions 75 dB (A)
Room temperature between 15°C and 35°C
Atmospheric humidity 30% to 75 % (no higher than 45% on aver-
age to prevent any possibility of condensa-
tion on the machine)