00195406-01_Version Description Setup Center 2.3_ger eng - 第23页
Existing Functions Rüstkontrolle Software Version Description SIPLACE Setup Center 2.3 23 6 Existing Functions 6.1 Rüstkontrol le Purpose Setup Center supports setup verification at the line wi th the equipment of the C,…
New Functions in Setup Center 2.3
Automatic configuration for Dragon Scanner
22 Software Version Description SIPLACE Setup Center 2.3

Existing Functions
Rüstkontrolle
Software Version Description SIPLACE Setup Center 2.3
23
6 Existing Functions
6.1 Rüstkontrolle
Purpose
Setup Center supports setup verification at the line with the equipment of the C, S-, F-, HS-, HF- and X-
Series.
Function
When SIPLACE Pro downloads a recipe, Setup Center automatically indicates the current setup in the
Setup Center GUI. The data recorded through Setup Center (e.g. during setup verification or refill check)
are sent to the station during forced setup verification. In this way Component Level Indicator and
Traceability can be supported. During online setup verification, the component level indicator needs to
be enabled and the threshold values need to be active.
While unforced setup verification takes place, the machine does not receive any setup verification data
and can produce immediately.
6.2 Offline Setup Verification
Purpose
Setup Center supports setup verification in the pre-setup area with the help of the docking station.
Function
Offline setup verification allows you to prepare setups in advance for production of boards and in parallel
with the current productions. This significantly reduces setup change times. If a setup is prepared in the
pre-setup area, the setup verification data are transferred to the production line by simply logging in the
changeover table.
A docking station is required additionally for the pre-setup of X-tables. A CAN-Bus – PCI Card is
necessary to connect the docking station. This card enables you to connect a maximum of 8 docking
stations. The card supports 2 CAN-Busses so that 4 docking stations can be connected to each bus. A
maximum of one CAN-Bus – PCI Card per computer is possible.
6.3 Changeover Table Management
Purpose
Setup Center supports changeover table management in both online and Offline Verification.
Function
Changeover table management enables you to set up tables, place them in the line and to monitor where
they are in the production process. If Online Verification is used in connection with Offline Verification,
on the same setup, changeover table management will reduce setup times, since setup verification only
needs to be performed once (offline) for each table. Tables can also be moved between different setups.
In this case, Setup Center creates a delta inventory, which records the components which remain the
same. The operator only needs to set up those component charges, which are different/ not yet present.
ATTENTION:
Machines of the C-Series have no interface for setup verification data and therefore support only
unforced setup verification.
Existing Functions
Splice monitoring
24 Software Version Description SIPLACE Setup Center 2.3
6.4 Splice monitoring
Purpose
Setup Center can deactivate a track if splice detection is expected but was not reported by the station.
This function is only valid for X feeders.
Function
In Setup Center a threshold value can be set for maximum quantity overrun. If a splice is expected on a
track and the threshold setting has been reached, the track is deactivated at the station and highlighted
in red in Setup Center. Using the splice error correction dialog (fix detected splice under-run), the user
can check the status of the track and confirm it. Setup Center will automatically correct the packaging
unit information and reactivate the track.
6.5 Teardown after foil torn error
Purpose
Setup Center can tear down a packaging unit after a foil torn error. This prevents incorrect traceability
data from being written if an X-feeder has not been torn down properly and this packaging unit was
changed on the same X-feeder in the station.
Function
The function "Teardown after foil torn error" can be activated in Setup Center. If the X-feeder reports a
foil torn error, the track is deactivated by the station. Setup Center sends a teardown instruction to the
station and tears the packaging unit down. This separates the link between packaging unit and feeder
both at the station and in Setup Center. The track needs to undergo verification again.
6.6 XML-Import
Purpose
This feature provides an interface for changing packaging unit data for external users/systems.
Function
The use of this function is supported via the XML import interface.
For a detailed description of XML import please refer to the document XML Import Setup Center 2.2 SP1,
item no. 00195379-xx.