Existing Restrictions Download Partial S etup Restrictions Software Version Description SIPLACE Setup Center 2.3 33 7 Existing Restrictions 7.1 Restrictions 7.1.1 Download Partial Setup Setup Center 2.3 cannot wo rk wit …

100%1 / 82
Existing Functions
XML Batch Import Backup/Restore SIPLACE Database
32 Software Version Description SIPLACE Setup Center 2.3
6.18.5 Backup/Restore SIPLACE Database
Purpose
Backup/Restore SIPLACE Database is a tool used to secure and restore the Setup Center and SIPLACE
Pro database, analog to the SIPLACE Pro Database Backup and Restore Tool.
Function
For detailed information please refer to the document Backup and Restore for SIPLACE Software
Systems with MSDE Database, item no. 00193873-xx.
6.19 XML Batch Import
Purpose
The XML Batch Import is the Setup Center interface for the the import of packaging data ofXML files.
Function:
Setup Center monitors configurable directories for XML files which contain packaging unit information.
If such a file is located in this directory the containing packackaging data is automatically imported.
Existing Restrictions
Download Partial Setup Restrictions
Software Version Description SIPLACE Setup Center 2.3
33
7 Existing Restrictions
7.1 Restrictions
7.1.1 Download Partial Setup
Setup Center 2.3 cannot work with modus Download Partial Setup.
7.1.2 Repair splice
When using splice sensors don't repair damaged packaging unit with splice because repair splice points
cannot be distinguished from the normal splice points.
7.1.3 Online Help
This version does not have an Online Help.
7.1.4 Operating mode
Mixed use of labels with „unique barcode“ and „Identical Component Lot unit“ is not supported.
7.1.5 Traceability
The component level indicator for the machines of the S-, F-, HS- and HF-Series recognizes identical
packaging unit information and ignores it. The menu field „Unique ID“ must therefore always be
transferred into a Traceability data field.
The settings „Identical Component Lot for linear feeders“ and „Identical Component Lot for tray
changers“ record the scanned „Unique ID“ in the data field „Batch“. The Traceability data for the
configured „Unique Id“ and „Batch“ barcodes will therefore both show the „Unique ID“.
Although Setup Center supports the management of packaging units with splice residues (packaging
unit with 3 tape segments), this leads to incorrect Traceability data for the residual segments. In the
Traceability data, this splice residue is shown as part of the packaging unit last refilled.
7.1.6 Tear down
The Machines of S-, F-, HS, and HF-Series do not yet support removal of packaging units. During
manual tear down, Setup Center sets packaging unit levels at the machine to zero and expects
threshold control to disable the tracks at the station. It is therefore important to enable threshold
control at the station, otherwise production can be continued in Setup Center, despite manual tear
down having been performed.
7.1.7 Barcode labels
The barcode fragment ExpiryDate (component expiry date on the packaging unit) is not evaluated
by Setup Center (no notification when time is exceeded).
7.1.8 Setup list
When SIPLACE Pro 4.1 is used, the setup lists printed out do not contain graphics of the
components.
7.1.9 Splice monitoring
The splice sensor functionality at the X-feeder requires an upgrade resp. exchange of soft- and
hardware which will be available in 10/2007. Until then this function is deactivated.
Existing Restrictions
Known Facts / Problems (General) Recovery Placement
34 Software Version Description SIPLACE Setup Center 2.3
7.1.10 Recovery Placement
Setup Center 2.3 cannot work with modus Recovery Placement.
7.2 Known Facts / Problems (General)
7.2.1 Setup Verification
It is a requirement that feeders are not pulled out or switched during setup verification. To put it
differently, as long as setup verification takes place for a single track, the feeder and the
corresponding packaging units must remain in the same location.
Urgent recommendation: when splicing a reel it must be verified immediatly (refill mode). A danger
exsit when extremely bad pickup rates occur and the CLI has small threshold values then unverified
components maybe placed. If a Splice is detected, the "active" function is available on the station
computer but should not be used. If no Splice sensors are installed the remaining quantity of a tape
running should be checked and corrected before splicing.
Use of the table check causes active component data to be overwritten at the station. This can reslt
in the lost of trace data if two reels are active on the track.
7.2.2 Quantity management
Quantity management for tray loaders is not supported.
If a reel does not have a unique ID barcode, the system can not differentiate between two elements
with identical quantities. If the packaging unit is taken from the feeder, information about the
remaining level is lost or unclear. It is no longer possible to monitor the quantities on the reels. If a
reel which was in this setup is then set up again, the user will need to manually correct the
component level with the help of the Component Level Indicator (CLI).
Wenn keine Gebindegröße als Barcode definiert ist, wird die Mengenangabe der Bauelemente aus
SIPLACE Pro verwendet. Die Mengeninformationen der Gehäuseform aus SIPLACE Pro werden
ignoriert.
7.2.3 Feeder
Tray feeders only support one component per level in the towers.
It is not possible to refill a level in an MTC or WPC. Refilling can only take place by replacing the
whole tray.
During Online Verification, the tray feeders WPC and MTC1 will only support a limited, forced setup
verification, since levels could otherwise be released by activation at the station.
The tape feeder 12/16 mm S tape feeder module and 24/32 mm S tape feeder module are only
supported, if the feeder type (e.g. 12mm S) remains the same in all setups used.
After a foil got torn at an X-feeder the new packaging unit will get activated without any new
verification. This is also the case when forced verification is activated. The activation can be
configured with or without scanning.
7.2.4 Line computer
The line computer is not supported.