S2-9XXX Series Dispensing System IOM Manual Maintenance
© 2023 Nordson Corporation 6-3
Table 6-1 Routine Maintenance Procedures (Continued)
Task Frequency Instructions
Clean Encoder Strips and
Read Heads
Every 3 months
Using lint-free cotton pads or swabs wetted with alcohol,
wipe the full length of the encoder strips and inspect for
damage. Similarly, clean the read heads to remove dirt,
dust, or foreign material.
Lubricate XY Axes Linear
Guides
Every 3 months See 6.10 Lubricating the Cables and Linear Guides.
Lubricate the Cables and
Linear Guides
Every 6 months
Every 3 months
for 24/7 use
See 6.10 Lubricating the Cables and Linear Guides.
Tension Mechanical Drive
Cables
Every 6-12
months
See 6.11 Tensioning the Cables.
Reset Laptop Battery Every 6 months See 6.8 Computer Battery Reset.
Tension Conveyor Belts As Needed See 6.13 Tensioning the Conveyor Belts.
Replace Conveyor Belts As Needed See 8.12 Replacing the Conveyer Belts.
6.5 Replacing Consumables
Consumables are items that are discarded and replaced on a regular basis. The following items are
common consumables and should be replaced at the intervals recommended in Table 6-1.
• Purge Boots
• Scale and Purge Cups
Tools and Materials Needed
• Needle-Nosed Pliers
• Replacement Purge Boot (Table 6-2)
• Isopropyl Alcohol
• Plastic Cups 1 oz. (29 ml) Pig of 200 (Item 39)
• Clean Shop Cloth
• Small Brush
• Rubber Gloves
• Personal Protective Equipment (as required)
Table 6-2 Purge Boot Colors, Sizes, and Compatible Needles
Purge Boot Color Inside Diameter Compatible Needle Gages Item Number
Orange 0.5 mm (0.020-in.) 26, 27, 30, 32 Item 40
Pink 0.8 mm (0.031-in.) 22, 23, 24, 25 Item 41
Green 1.1 mm (0.045-in.) 19, 20, 21 Item 43
Olive* 3.0 mm (0.120-in.) 14, 15, 16, 18 Item 42
*Recommended size for nozzles on DJ-2000 and DJ-9000 Series Dispensing Valves.

S2-9XXX Series Dispensing System IOM Manual Maintenance
6-4 © 2023 Nordson Corporation
6.5.1 Replacing Purge and Scale Station Cups
The cups in the purge and scale stations should be replaced at the intervals recommended in Table 6-1.
To replace the purge and scale cups (Figure 6-1):
WARNING! Follow all local regulations, the material manufacturer SDS, and facility practices
concerning personal protective equipment and disposal of hazardous materials.
NOTE The setup procedure does not need to be performed after replacing the purge station and
scale station cups.
1. When the dispensing system is idle, open the dispensing area door.
2. Remove the covers on the purge station and scale stations.
3. Remove and discard the plastic cups inside the purge and scale stations and inspect the
interior surfaces for spilled fluid.
If the interior of the purge station has spilled fluid, clean with the recommended
cleaning agent and a soft cloth.
If the interior of the scale station has spilled fluid, contact Asymtek Technical Support.
CAUTION! Avoid putting downward pressure on the scale or damage to the sensitive
weighing mechanism will occur.
4. Place a new plastic cup inside of each station.
5. Clean the covers using isopropyl alcohol and a soft cloth.
6. Reinstall the covers and close the dispensing area door.

S2-9XXX Series Dispensing System IOM Manual Maintenance
© 2023 Nordson Corporation 6-5
Item Description
1 Purge Boot
2
Purge Station Cover
3 Purge Station Cup
4 Purge Station
5 Scale Station Cover
6 Scale Station Cup
7 Scale Station
Figure 6-1 Replacing the Purge and Scale Station Cups
5
6
4
3
1
7
2