Spectrum Operating Manual - 第216页

S2-9 XX X Se ri es Disp ensi n g Syst em IOM Man ual Specifications 9-8 © 2023 Nordson Corporatio n To p View (mm ) B ack View (mm) Figure 9-4 S2 - 9XXC S yste m Dime nsions (2 of 2 )

100%1 / 222
S2-9XXX Series Dispensing System IOM Manual Specifications
© 2023 Nordson Corporation 9-7
9.5.2 S2-9XXC
NOMINAL PASSLINE HEIGHT (MM)
PASSLINE
RANGE
FOOT
(under machine
clearance)
MIN 913 66
NOMINAL
(SMEMA
1
)
953 106
MAX 965 118
1
SMEMA = 953 mm ± 12.5 mm
Front View (mm)
Side View (mm)
Figure 9-3 S2-9XXC System Dimensions (1 of 2)
S2-9XXX Series Dispensing System IOM Manual Specifications
9-8 © 2023 Nordson Corporation
Top View (mm)
Back View (mm)
Figure 9-4 S2-9XXC System Dimensions (2 of 2)
S2-9XXX Series Dispensing System IOM Manual Specifications
© 2023 Nordson Corporation 9-9
9.6 Stability Analysis
Table 9-3 Stability Analysis
Specifications
Center of Gravity
CG side to side
CG front to back
CG above the floor
295.6 mm (11.63 inches)
587.4 mm (23.12 inches)
800.7 mm (31.52 inches)
(left foot to CG)
(front foot to CG)
(floor to CG)
Weight Distribution
(1)
Front Left
Front Right
Rear Right
Rear Left
92.0 kg (202.9 lbs)
93.9 kg (207.1 lbs)
94.2 kg (207.6 lbs)
91.8 kg (202.4 lbs)
Seismic Loading
Transverse Stability
Anchorage Force
Longitudinal Stability
Anchorage Force
Anchors Required
208.6 kg (460 lbs)
Anchors Required
64.4 kg (142 lbs)
Tilt Angle
(1)
Transverse Stability-CCW
Transverse Stability-CC
Longitudinal Stability-CCW
Longitudinal Stability-CC
17.1
16.8
30.8
31.5
(1)
User facing front end of the unit.