S2-9XXX Series Dispensing System IOM Manual Safety
© 2023 Nordson Corporation 2-17
Situations where LOTO practices might not be required are when troubleshooting electrical, pneumatic,
or hydraulic components or assemblies that make de-energizing the whole system impractical.
Troubleshooting or servicing the dispensing system while powered up and operating should only be
accomplished by fully trained and qualified personnel. There should always be a second person present
when performing maintenance on a system under power.
To lockout/tagout the electrical and pneumatic energy (Figure 2-13):
1. Turn the main circuit breaker on the rear of the system to the
OFF (0) position.
2. Unplug the main power cable from the back of the power manager.
3. Rotate the main air pressure knob counterclockwise until the gauge registers 0 kPa (0 psi)
and then disconnect the main air supply by the quick release fitting.
4. Install an approved, keyed lock on the locking flange of the main circuit breaker so it cannot
be turned on; tag it with an approved tag.
Ensure that the owner, date, reason, and estimated time for repair are clearly marked on
the tag.
5. Install an approved lockout clamp and keyed lock onto the power connector so it cannot be
reconnected to the power manager and attach an approved tag.
Ensure the owner, date, reason, and estimated time to repair are clearly marked on
the tag.
6. Install an approved lockout clamp and keyed lock onto the pneumatic fitting so it cannot be
reconnected to the main air regulator and attach an approved tag.
Ensure the owner, date, reason, and estimated time to repair are clearly marked on the
tag.
NOTE Warning tags document the name of the technician taking the equipment out of operation,
the date, and other facility-required information. It is a warning that the equipment cannot
be put back into operation until the authorized technician has removed the tag.
WARNING! If your dispensing system is equipped with a heater, allow sufficient time for the
heater to cool prior to performing maintenance or service. Failure to do so may
result in serious burn injury.
S2-9XXX Series Dispensing System IOM Manual Safety
2-18 © 2023 Nordson Corporation
Figure 2-13 Electrical/Pneumatical Lockout/Tagout
S2-9XXX Series Dispensing System IOM Manual Safety
© 2023 Nordson Corporation 2-19
2.16 Light Beacon
The light beacon is a device that displays system status and can warn the operator when fault conditions
exist. The beacon has red, yellow, green, and blue lights that can be solid or flashing. The beacon also has
an audible alarm. Table 2-4 provides possible reasons for each color indication.
Software and hardware share control of the beacon lights. Sometimes, hardware-driven displays override
those caused by software conditions and sometimes software-driven displays override. Safety critical
conditions always have priority. Flashing light software commands have priority over solid light
commands.
NOTE Light beacon action can be custom configured using the beacon control feature. Refer to
the Fluidmove User Guide or Fluidmove Online Help for details.
See Section 7 - Troubleshooting for suggested recovery from common fault conditions.
Table 2-3 Light Beacon Color Indications
Beacon Color System Status
RED
ALERT
All motion, outputs, dispensing valve, and motion controls are disabled until
the fault is cleared.
One of the following conditions may exist:
A. Solid - Emergency stop condition or heater error.
B. Flashing - General error or vision error. Software driven error message is
displayed on the computer monitor.
C. Solid or Flashing - Software has been configured to display a solid or
flashing red light.
YELLOW
CAUTION
System in a low power state or lacks sufficient air pressure.
One of the following conditions may exist:
A. Solid - Front door is open (Interlock activated).
B. Solid or Flashing - Software has been configured to display a solid or
flashing yellow light.
GREEN
OPERATION
One of the following conditions may exist:
A. Solid - The system is fully operational with the front door closed.
B. Solid or Flashing - Software has been configured to display a solid or
flashing green light.
BLUE
USER DEFINED
A. Solid - Software has been configured to display a solid blue light.
B. Flashing - Software has been configured to display a flashing blue light.