© 2023 Nordson Corporation 4-1
4 Operation
4.1 Overview
The sections that follow describe the general sequence of actions necessary to power on and shutdown the
dispensing system. This section covers the following topics:
Powering on the Dispensing System
Daily Routine Procedures
Starting Fluidmove for Windows
Running Production
Camera States
Shutdown
WARNING! DO NOT operate the dispensing system unless you have been trained to do so.
Operating the dispensing system without proper training may result in personal
injury or dispensing system damage.
4.2 Safety First
Operation of your dispensing system involves heat, air pressure, electrical power, mechanical devices,
and the use of hazardous materials. Read this manual in its entirety before attempting any system or
component operation. It is essential for all personnel working on or around the dispensing system to fully
understand the hazards, risks, and safety precautions associated with operating the system. When properly
operated and maintained, the dispensing system is safe and reliable. See Section 2 - Safety for additional
information.
4.3 Powering on the Dispensing System
To power on the dispensing system (Figure 4-1):
1. Verify that the main power cord is connected to the main power inlet and the facility power
source.
2. Verify that the facility air is at the recommended pressure level and connected to the main air
pressure regulator inlets, see
3.12 Connecting the Power and Air Supply.
3. Turn the main circuit breaker on the back of the system to the
ON position.
4. Check the EMO buttons to see if they have been activated. If one has been activated, deactivate
it by turning the red knob clockwise until the knob pops out.
5. Make sure the interlock signal is not interrupted. Close the dispensing area door if applicable.
6. Turn the laptop computer power button
ON (l).
The laptop computer should begin the boot up sequence.
7. Press the ON (l) button on the front panel.
The dispensing system should be in a powered-up state and the digital gauges and green
power button should be on. If not, make sure the power cord is properly connected to the
dispensing system and to an active facility power source.
S2-9XXX Series Dispensing System IOM Manual Operation
4-2 © 2023 Nordson Corporation
For machines equipped with a vent air switch (machines that require vent air), system
power-up is delayed by 60 seconds after the ON button is pushed. The 60 second delay is to
provide enough time to exhaust the work-cell from any flammable or explosive vapors.
It may take several minutes for the camera to acquire a connection with the laptop
computer. DO NOT attempt to run Fluidmove or DALSA programs during this time.
A blue camera icon with a red X crossing it will be displayed on the Windows taskbar.
After the camera is connected, the red X disappears and a message pops up stating that
the “device has limited or no functionality.This is normal and means that you cannot
connect to the Internet with this device
.
Item
Description
1 On Button
2 Off Button
3 EMO
Figure 4-1 Front Panel Buttons
4.4 Starting Fluidmove for Windows
The Fluidmove Software is installed and configured at the factory prior to shipping. Refer to the
Fluidmove User Guide or Fluidmove Online Help to start and configure Fluidmove for the dispensing
system.
If you need to reinstall the software or add or remove hardware you will need to reconfigure the software.
Refer to the Fluidmove User Guide or Fluidmove Online Help.
1