7OM-1625-004_w - 第150页

7OM-1603 Chapter 4 : 3. Maintenance Spots 4-25 W ARNING Pay close attention to the cutter blade during the maintenance work. • Lack of attention will result in a hand injury , etc. Wear gloves and take the greatest care …

100%1 / 187
7OM-1603
4-24
Chapter 4 : 3. Maintenance Spots
WARNING
Pay close attention to the cutter blade during the
maintenance work.
Lack of attention will result in a hand injury, etc.
Wear gloves and take the greatest care in performing
the work.
Be sure to attach the cutter blade cover to the cut unit
during the maintenance work for safety purposes.
Linear Guides
Every 3 Months Lubrication
(DAPHNE EPONEX GREASE No. 1)
Required Time: 10 minutes
(1) Remove 12 screws.
(2)
Use Type N nozzle.
Type N
Note
Wipe old grease out using a rag and apply new grease
onto the linear guide (upper and lower sides).
F7D18
0908-001
7OM-1603
Chapter 4 : 3. Maintenance Spots
4-25
WARNING
Pay close attention to the cutter blade during the
maintenance work.
Lack of attention will result in a hand injury, etc.
Wear gloves and take the greatest care in performing
the work.
Be sure to attach the cutter blade cover to the cut unit
during the maintenance work for safety purposes.
Attachment Position of
Cut Unit Fixing Jig
Flat Ring
Every Year Replacement
Required Time: 10 minutes
(1) Remove 11 screws and detach the cover.
(2) Use the cutter unit fixing jig with the tape clamp closed to fix the urethane clamp section.
(3) Loosen and remove the seal-cover bolt (6 locations) in the order of No. 1 to No. 6,
using a wrench.
(4) Change the flat ring.
(5) Put the shield cover and attach the bolts (6 locations) on it.
(Attach it using the torque driver attached to the line accessory.)
(Tightening Torque : 18.6 to 22.6 Ncm (1.9 to 2.3 kgfcm))
Bolts
Bolts
F7D19
1102-002
7OM-1603
4-26
Chapter 4 : 3. Maintenance Spots
CAUTION
Whentheatringiscut,takecarenottogetinjuredby
the commercially available cutter.
1102-001