FUJI 24 HEAD Replacing ALL syringe_IPS.pdf - 第34页

Edition 2.0 NXT/NXT2 Repair Training T ext H12HS(Q) Hea d FK-9F98-61-0E 7-6 FUJI MACHINE MFG . CO., L TD. 8. Use the syringe pin extraction jig ( AA1WE0* ) to remove the pin from the syringe. Note: This syringe pin extra…

100%1 / 180
Edition 2.0 NXT/NXT2 Repair Training Text
H12HS(Q) Hea
d
FK-9F98-61-0E 7-5 FUJI MACHINE MFG. CO., LTD.
4. Remove the syringe pusher with the 5.0 mm spanner (PB 3751*) and 4.0 mm spanner
(PB9769*). Firstly, set the 5.0 mm spanner on the pusher as shown in the following
photo.
5. Next, set the 4.0 mm spanner (PB9769*) on the syringe as shown in the following
photo.
6. Fix the upper 5.0 mm spanner by hand and turn the lower 4.0 mm spanner clockwise
(as viewed from above the head) to remove the pusher.
7. Remove the syringe gear from the syringe.
Caution!
The H12HS syringe gear is a scissors gear. When removing the gear, be
careful not to lose the spring from between the gears.
PB97690
PB3751*
CONFIDENTIAL
SmartechMr.J FSun
Edition 2.0 NXT/NXT2 Repair Training Text
H12HS(Q) Hea
d
FK-9F98-61-0E 7-6 FUJI MACHINE MFG. CO., LTD.
8. Use the syringe pin extraction jig AA1WE0* to remove the pin from the syringe.
Note: This syringe pin extraction jig (AA1WE0*)
is also used for the H12S head.
Caution!
If the H08 syringe pin extraction jig
AA75901*
is used instead of the H12
syringe pin extraction jig
AA1WE0*
it is not possible to fully extract the
pin. Be sure to use the H12 syringe pin extraction jig.
9. Remove the bearing and spring from the syringe.
10. After removing the syringe from the rotary holder, clean the inside of the rotary holder.
Note: Use an air gun or cloth to clean the inside of the rotary holder.
11. Prepare the new syringeAA65D04.
Note:
If the scissors gear or inner spring is damaged, prepare a new scissors gear
or spring as required.
Syringe pin extraction
jig AA1WE0*
Bearing
Spring
CONFIDENTIAL
SmartechMr.J FSun
Edition 2.0 NXT/NXT2 Repair Training Text
H12HS(Q) Hea
d
FK-9F98-61-0E 7-7 FUJI MACHINE MFG. CO., LTD.
12. Use a grease removing agent to remove grease from the syringe surface, and then
use a cloth to apply a thin layer of Biral T&D to the syringe.
13. Set a new felt ring PZ26702 and the felt retainer PJ17001into the rotary holder in
which the syringe is to be inserted.
14. Insert the syringe into the rotary holder.
Use a cloth to apply a
thin layer of Biral T&D
CONFIDENTIAL
SmartechMr.J FSun