FUJI 24 HEAD Replacing ALL syringe_IPS.pdf - 第36页
Edition 2.0 NXT/NXT2 Repair Training T ext H12HS(Q) Hea d FK-9F98-61-0E 7-8 FUJI MACHINE MFG . CO., L TD. 15. Use the push-pull gauge ( DPS-5 ) to measure the slide resi stance of all the syringes. Check that the measure…

Edition 2.0 NXT/NXT2 Repair Training Text
H12HS(Q) Hea
d
FK-9F98-61-0E 7-7 FUJI MACHINE MFG. CO., LTD.
12. Use a grease removing agent to remove grease from the syringe surface, and then
use a cloth to apply a thin layer of Biral T&D to the syringe.
13. Set a new felt ring (PZ26702) and the felt retainer (PJ17001)into the rotary holder in
which the syringe is to be inserted.
14. Insert the syringe into the rotary holder.
Use a cloth to apply a
thin layer of Biral T&D
CONFIDENTIAL
SmartechMr.J FSun

Edition 2.0 NXT/NXT2 Repair Training Text
H12HS(Q) Hea
d
FK-9F98-61-0E 7-8 FUJI MACHINE MFG. CO., LTD.
15. Use the push-pull gauge(DPS-5)to measure the slide resistance of all the syringes.
Check that the measured value is 0.98 N or less (within 100 g).
16. Attach the spring and bearing to the syringe.
17. Use the H12 syringe pin insertion jig (AA1XC0*) to insert the pin into the syringe.
Note: the H12 syringe pin insertion jig (AA1XC0*) is also used for the H12S head.
H12 syringe pin in
(AA1XC0*)
Bearing
Spring
Push-pull gauge(DPS-5)
CONFIDENTIAL
SmartechMr.J FSun

Edition 2.0 NXT/NXT2 Repair Training Text
H12HS(Q) Hea
d
FK-9F98-61-0E 7-9 FUJI MACHINE MFG. CO., LTD.
18. Attach the syringe gear to the syringe. Follow the procedure below when using the
H12HSθ-axis phase alignment jig (AA6LH0*).
Note: The PM6637* component of the H12HS θ-axis phase alignment jig (AA6LHO*) is
the same as that used for the H12Sθ-axis phase alignment jig
.
However, the
jig PM07RA is only for the H12S head.
1) Attach the H12HSθ-axis phase alignment jig(PM6637*) to the rotary holder.
Note:
The H12HSθ-axis phase alignment jig
(
PM6637*
)
is also used as the H12S
head θ-axis phase alignment jig.
2) Attach the H12HSθ-axis phase alignment jig (PM07RA*)to all the syringes.
Caution: The jig (PM07RA*
)
should only be used on the H12HS head. It is not for use
on the H12S head.
H12HSθ-axis phase
alignment jig (AA6LH0*)
PM6637*
PM07RA*
PM6637*
PM07RA*
CONFIDENTIAL
SmartechMr.J FSun