7 First Booting after Installation
When a machine is booted for the first time after installation, the station software detects for the
most part independently which hardware components are used via the Auto-Configuration
feature. Certain settings, such as CAN card type, table type, lamp indicators and pin magazines
cannot be detected automatically and must be selected manually.
Generally, the operator will be prompted to confirm or reject any configuration changes.
By clicking the + sign in front of the auto-configuration text, the message list opens and the used
hardware components are displayed.
The Machine service activity level is required to execute the auto-configuration. The activity level
can be changed under Settings User.
Required manual entries
The entries to be selected manually in the Value column are tagged with a '?' (question mark). All
these values must be adapted before the auto-configuration can be finished.
As of station software version 705.03 you must set, whether the lamp indicators on the placement
machine towers shall be displayed two-colored (green / white) or three-colored (green / white / red)
for all placement machines of the SX-series and DX-series. More information about the two lamp
indicator systems can be found in the Feature Description of the station software, item number
[00197741-xx].
7.1 X-Series Placement Machines
If the Coplan computer has been installed, you must additionally confirm or reject the 3D
Coplan sensor in the auto-configuration.
7.2 X-Series S Placement Machines
When the X-Series S placement machines are booted for the first time you must select the
CAN card (two or four CAN buses):
7.2.1 X4i S Placement Machine
When the X4i S placement machine is booted for the first time you must select the following
options manually:
If a TrayStak Feeder is used, this must be defined for each location concerned in the auto-
configuration.
Table position (inner and outer)
Station Software Version 712.1 (R19-1) / Installation Manual 05/2019 Edition
66
7.3 SX-Series Placement Machines
7.3.1 SX1/SX2 (V2) Placement Machine
When the SX1/SX2 (V2) placement machine is booted for the first time you must select the
following options manually:
Table configuration for both locations.
If the manual tray Carrier SX is used, the insert frame with the fold-away tape guide
channel is required. For this, the 60 slots (outer position, fold-away tape duct) table
configuration must be selected for each location concerned. Thus, the 27x27 reject bin and
the left reject channel on the location are excluded from the configuration.
CAUTION
If this setting is not made, the component may be rejected over the tray and the Z axis
may dash hard against the tray.
If the Coplan computer has been installed, you must additionally confirm or reject the 3-D
Coplan sensor.
7.3.2 SX+ Placement Machine
If the SX+ placement machine is to be used without gantries, this has to be configured in the auto-
configuration after the machine has been booted.
For this, select Ignore gantries at the processing area in the machine configuration dialog.
7.3.3 SX4 Placement Machine
When the SX4 placement machine is booted for the first time you must select the SX4 Flexible
entry for Machine frame manually in the auto-configuration, if there are tables in outer position
in processing area 2, as this is not detected automatically via sensors.
Tables in outer position are used when stationary cameras are in use.
Otherwise you select the SX4 High Speed entry.
7.4 DX-Series Placement Machines
When the DX placement machines are booted for the first time you must select the following
options manually:
For C&P12 placement head: height position (altitude)
Lamp indicators (two-colored or three-colored)
Table position:
inner 60 tracks
outer 60 tracks
outer with 30 tracks + free location for tray or WPC
Confirm/reject 3-D Coplan sensor
Station Software Version 712.1 (R19-1) / Installation Manual 05/2019 Edition
67
7.5 TX-Series (V1 and V2) Placement Machines
When the TX placement machines are booted for the first time you must select the following
options manually:
If SIPLACE JTF-ML is used, select the X-Table, multi tray feeder support option for the
JTF-ML Table 40X on Location 1.
If no reject plate has been installed, you must disable this option explicitly.
7.6 Checking/Updating the Embedded Software
If the correct embedded SW versions are not available on the machine, the machine boot gets
interrupted.
In this case, perform an embedded SW download.
Start an overall reference run for the machine.
7.7 Storage Location of the Machine Files (Calibration Data etc.)
The machine-specific configuration, measurement and parameter data is stored in XML files under
C:\Sirio\Work\Individual. These XML files contain all calibration data.
7.8 Storing Calibration Data in the EEPROM
In order to use the fast head exchange feature, the head specific calibration data has to be stored
in the EEPROM. For placement heads with no head specific calibration data stored within the
EEPROM, the available data on the station computer will be stored in the EEPROM of the
respective placement head as follows.
Requirement:
The embedded SW versions have been updated.